Skip to main content

IBM FlashSystem 840 Product Guide

Web Doc

thumbnail 

Published on 16 January 2014, updated 13 February 2015

  1. View in HTML
  2. .PDF (1.0 MB)

Share this page:   

IBM Form #: TIPS1079


Authors: Orlando Karen and Carsten Larsen

    menu icon

    Abstract

    The IBM® FlashSystem™ 840 storage system delivers high performance, efficiency, and reliability for shared enterprise storage environments, helping clients around the world address performance issues with their most important applications and infrastructure. IBM FlashSystem 840 is designed to provide scalable performance for the most demanding enterprise class applications, including virtualized or bare-metal OLTP and OLAP databases, virtual desktop infrastructures, technical computing applications, and cloud environments.

    February 6, 2015 - Updated to add the latest R1.3 information for the new 1300W power supply option and GUI productivity information

    .

    Contents

    This IBM® Redbooks® Product Guide describes IBM FlashSystem 840. Today's global organizations depend upon the ability to unlock business insights from massive volumes of data, and they need to be able to do it faster than the competition. Flash technology has changed the economics of today's data center by eliminating storage bottlenecks. Flash technology has redefined the performance, efficiency, and reliability of data-intensive applications. In fact, IBM flash storage offerings provide extreme input/output operations per second (IOPS) performance in a power-efficient footprint.

    FlashSystem 840 is optimized for the data center to enable organizations of all sizes to strategically harness the value of stored data. IBM FlashSystem 840 delivers a competitive advantage for the modern organizations and enterprises. It provides flexible capacity and extreme performance for the most demanding applications, including virtualized or bare-metal online transaction processing (OLTP) and online analytical processing (OLAP) databases, virtual desktop infrastructures (VDI), technical computing applications, and cloud environments. The system accelerates response times with IBM MicroLatency access times as low as 90 µs write latency and 135 µs read latency to enable faster decision making.

    The introduction of a low capacity 1 TB flash module allows FlashSystem 840 to be configured in capacity points as low as 2 TB in protected RAID 5 mode. Coupled with 10 GB iSCSI, FlashSystem is positioned to bring extreme performance to small and medium sized businesses (SMB) and growth markets. Figure 1 shows FlashSystem 840.

    FlashSystem 840
    Figure 1. FlashSystem 840

    Did you know?

    • FlashSystem 840 is configurable with 2 - 48 TB of usable capacity for increased flexibility.
    • FlashSystem 840 provides four flexible interface types including Fibre Channel, Fibre Channel over Ethernet (FCoE), iSCSI, and InfiniBand to easily integrate into existing SAN environments.
    • FlashSystem 840 is cloud-optimized with support for 10 Gbit iSCSI interfaces, allowing private cloud environments and Managed Service Providers (MSPs) to take advantage of high-performance storage inside existing Ethernet-based infrastructures.
    • All active parts are hot-swappable, including the flash modules.


    Key features

    FlashSystem 840 provides extreme performance, enterprise-class reliability, energy efficiency, and optional data-at-rest encryption.

    Scalability and performance

    FlashSystem 840 has the following scalability and performance features:
    • IBM MicroLatency provides latency that is measured in microseconds
    • High aggregate performance (bandwidth) and IOPS (I/Os per second)
    • Two hot-swappable canisters, providing connectivity to the host
    • Flexible interface types of Fibre Channel, Fibre Channel over Ethernet (FCoE), iSCSI and InfiniBand
      • Up to 16 ports of 8 Gbps or eight ports of 16 Gbps Fibre Channel
      • Up to 16 ports of 10 Gbps FCoE
      • Up to 16 ports of 10 Gbps iSCSI
      • Up to eight ports of 40 Gbps quad data rate (QDR) InfiniBand
    • Slots for up to 12 hot-swappable flash storage modules (1 TB, 2 TB or 4 TB modules)
    • Configurable 2 - 48 TB of capacity for increased flexibility

    Reliability, availability, and serviceability

    FlashSystem 840 storage products deliver the following enterprise-class reliability features:
    • Concurrent code load enables customer applications to remain online during firmware upgrades to all components, including the flash modules.
    • Hot-swappable flash modules by way of tool-less front panel access. If a flash module failure occurs, critical customer applications can remain online while the defective module is replaced.
    • Redundant hot-swappable components. RAID controllers, management modules, interface cards (all contained in the canister), batteries, fans, and power supplies are all redundant and hot-swappable. All components are easily accessible through the front or rear of the enclosure, so IBM FlashSystem 840 does not need to be moved in the rack and no top access panels or cables need to be extended.
    • RAID 0 and RAID 5 configurations for reliability that suits varying client needs.
    • As of FlashSystem 840 release 1.3, before enabling RAID 0, you must submit a Solution for Compliance in a Regulated Environment (SCORE)/request for price quotation (RPQ).To submit a SCORE/RPQ, contact your IBM representative.

    • System-wide RAID 5 with easily accessed front-loadable hot-swappable flash modules to help prevent data loss and improve availability.
    • IBM Variable Stripe RAID™ (VSR), which is a patented IBM technology that provides an intra-module RAID stripe on each flash module.
    • Two-dimensional (2D) Flash RAID, which consists of IBM Variable Stripe RAID and system-wide RAID 5. Variable Stripe RAID technology helps reduce downtime and maintain performance and capacity in the event of partial or full flash chip failures. System-wide RAID 5, with easily accessed hot swappable flash modules, helps prevent data loss and promote availability.
    • Flash Cell leveling, which is a technology that reduces flash cell wear because of electrical programming.

    Energy and space efficiency

    FlashSystem 840 has the following features:
    • The new 1300W power supply, feature AF1H, for high-line voltage provides IBM FlashSystem 840 with a high-power alternative to run at maximum performance for longer durations during power supply servicing, resulting in more predictable performance under unexpected failure conditions. The maximum and minimum voltage ranges (Vrms) and associated high line AC Ranges are specified below:

    • Minimum-180V, Nominal- 200V-240V, Maximum-265V

    Notes:
    • The two power supplies must be matched; you cannot have one 900W and one 1300W power supply.
    • It is recommended that the two power supplies are placed on different circuits.
    • The 900W power supply, feature AF1M, Standard Power Supply has nominal 625 W power consumption (for a 70/30 read/write workload on an eight module, 2 TB FlashSystem), and uses two standard, single-phase (100 v - 240 v) electrical outlets.
    • Space-efficient 2U form factor that is ideally suited for today's data centers.

    Battery Reconditioning

    This release enables a battery reconditioning feature that calibrates the gauge that reports the amount of charge on the batteries. On systems that have been installed for 10 months or more, or systems that have experienced several power outages, the recommendation to run "battery reconditioning" will appear in the Event Log shortly after upgrading. Refer to version 1.3 of the FlashSystem Knowledge Center for more information:
    http://ibm.co/1o0Z8br

    Manageability and security

    FlashSystem 840 offers the following manageability and security features:
    • Advanced security for data at rest with hardware-accelerated AES-XTS 256 bit encryption
    • Graphical user interface (GUI) and command-line interface (CLI) based on IBM SAN Volume Controller, which is available in any supported browser
    • SAN Volume Controller CLI
    • Simple Network Management Protocol (SNMP)
    • Email alerts
    • Syslog redirect to send system log messages to another host


    Architecture and key components

    IBM FlashSystem 840 enclosures consist of two fully redundant canisters. Each canister contains a RAID controller, two interface cards, and a management controller with an associated 1 Gbps Ethernet port. Each canister also has a USB port and two hot-swappable fan modules.

    In addition to the canisters, IBM FlashSystem 840 enclosures include two battery modules and two power supplies, which are all redundant and hot-swappable. All components are easily accessible by way of the front or rear of the unit, so IBM FlashSystem 840 does not need to be moved in the rack, and any top access panels or cables do not need to be extended. This makes servicing the unit easy.

    The front of the enclosure has the two battery modules on the far left of the enclosure and twelve flash module slots to the right of the battery modules, as shown in Figure 2.

    Front view of FlashSystem 840
    Figure 2. Front view of FlashSystem 840

    Figure 3 shows the components of IBM FlashSystem 840 from the rear. One of the two canisters is removed, and you see two interface cards and two fan modules. The power supply unit to the right of the fans provides redundant power to the system. All components are concurrently maintainable except for the midplane, enclosure LED board, and power interposer board. All external connections are from the rear of the system.


    Figure 3. Rear view of FlashSystem 840 with one canister removed


    FlashSystem 840 contains two canisters. Each canister contains a RAID controller, two interface cards, and a management controller with an associated Ethernet port and a USB connector.

    Figure 4 shows a rear view of FlashSystem 840 with Fibre Channel (FC) or Fibre Channel over Ethernet (FCoE) interfaces. The canisters are to the left (large units) and the two power supply units are to the right (small units).


    Figure 4. Rear view with Fibre Channel interface cards
    Specifications
    Table 1 lists the specifications for FlashSystem 840.

    Table 1. Specifications (part 1 of 2)
    SpecificationDescription
    Model9840-AE1, 9843-AE1.
    Form factor2U rack-mounted enclosure.
    Flash module quantityUp to 12 flash modules in increments of 2, 4, 6, 8, 10, or 12. These modules can be either 1 TB, 2 TB, or 4 TB and cannot be intermixed.
    Flash typeEnterprise multilevel cell (eMLC).
    Raw capacity (TB/TiB)2.75 TB/2.5 TiB, 5.5 TB/5 TiB, 8.25 TB/7.5 TiB, 11 TB/10 TiB, 16.5 TB/15 TiB, 22 TB/20 TiB, 27.5 TB/25 TiB, 33 TB/30 TiB, 44 TB/40 TiB, 55 TB/50 TiB, 66 TB/60 TiB.
    RAID 0 usable capacity (TB/TiB) a 2 TB/1.88 TiB, 4 TB/3.75 TiB, 6 TB/5.63 TiB, 8 TB/7.5 TiB, 10 TB/9.34 TiB, 12 TB/11.25 TiB, 16 TB/15 TiB, 20 TB/ 18.75 TiB, 24 TB/22.25 TiB, 32 TB/30 TiB, 40 TB/37.5 TiB and 48 TB/45 TiB.
    RAID 5 usable capacity (TB/TiB)2 TB/1.88 TiB, 4 TB/3.75 TiB, 6 TB/5.63 TiB, 8 TB/7.5 TiB, 10 TB/9.34 TiB, 12 TB/11.25 TiB, 16 TB/15 TiB, 20 TB/ 18.75 TiB, 24 TB/22.25 TiB, 32 TB/30 TiB, and 40 TB/37.5 TiB..
    Maximum capacityFor RAID 0, the maximum capacity is 48 TB.
    For RAID 5, the maximum capacity is 40 TB.
    Flash module protectionECC error correction, Variable stripe RAID data protection, overprovisioning, and IBM two-dimensional Flash RAID.
    RAID supportRAID 0 and RAID 5.
    Host interfacesTwo RJ45 Ethernet connections for management and up to 16 host interface connections, which are either SFP+ FC or QSFP InfiniBand connections, depending on the selected features.
    Maximum bandwidth8 GBps Read (100%, sequential), 4 GBps Write (100%, sequential).
    Read IOPS1,100,000.
    Write IOPS600,000.
    Read latency135 µs.
    Write latency90 µs.
    Maximum volume support (LUNs)2 K (2048).
    System management
    • IBM SAN Volume Controller GUI is available in any supported browser.
    • IBM SAN Volume Controller CLI.
    • SNMP.
    • Email alerts.
    • Syslog redirect.
    CoolingFour hot-swappable fan modules.

    Table 1. Specifications (part 1 of 2)
    Specification Description
    Power supply1300 watts, high-power alternative to run at maximum performance for longer durations during power supply servicing. Two redundant hot-swap 200 - 240V AC auto-sensing power supplies.
    Input power900 watts
    Heat dissipationApproximately 2133 BTU. For maximum configurations, it could go as high as 3753 BTU (maximum configuration RAID 5).
    Hot-swap partsAll active components.
    Security featuresAES-XTS 256 bit data-at-rest encryption with local key management.
    Platforms supported For specific information, see the IBM System Storage Interoperation Center (SSIC) at http://www.ibm.com/systems/support/storage/ssic/interoperability.wss
    WarrantySet of Machine Types in AAS, 24 X 7 Service level Agreement, 4 hour response time:
    • 9840-AE1 - One year.
    • 9843-AE1 - Three years.
    Service and supportOptional warranty service upgrades and post-warranty services are available on site with 24x7 2-hour, 24x7, or 9x5 same day, or 9x5 next business day response,
    DimensionsWidth: 445 mm (17.5 in.) (19-inch Rack Standard)
    Depth: 761 mm (29.96 in.)
    Height: 86.2 mm (3.39 in.)
    a. As of FlashSystem 840 release 1.3, before enabling RAID 0, you must submit a SCORE/RPQ to IBM. To submit a SCORE/RPQ, contact your IBM representative

    Models

    The following set of Machine Types are supported in AAS as follows:
    • 9840-AE1 - Warranty period 1 year
    • 9843-AE1 - Warranty period 3 years

    All FlashSystem 840 storage systems ship with the backup batteries, flash modules and blanks, power supplies, fans, and canisters preinstalled. (The flash module type and quantity and the host interface I/O cards must be pre-specified.)

    The following items are also shipped with FlashSystem 840:
    • System chassis
    • Rack rail kit
    • Warranty documentation
    • Printed quick start guide
    • Selected power cables
    • Selected interface cables (if any)


    Interface cards

    IBM FlashSystem 840 supports only one interface type per system. For example, it is not possible to use two Fibre Channel interface cards and two InfiniBand interface cards in the same enclosure.

    Interface cards are sold in groups of four for a total of eight or 16 ports for each system.

    IBM FlashSystem 840 supports the following interface protocols and number of connections:
    • Fibre Channel (16 ports of 8 Gbps; these ports also support 4 Gbps)
    • Fibre Channel (eight ports of 16 Gbps; these ports also support 8 Gbps and 4 Gbps)
    • Fibre Channel over Ethernet (FCoE) (16 ports of 10 Gbps FCoE)
    • Internet Small Computer System Interface (iSCSI) (16 ports of 10 Gbps iSCSI)
    • InfiniBand (eight ports of QDR InfiniBand 40 Gbps)


    Fibre Channel support

    Fibre Channel and Fibre Channel over Ethernet (FCoE) protocols use the same interface cards. However, only one protocol is supported per IBM FlashSystem 840 enclosure. Figure 5 shows the Fibre Channel interface card.

    Fibre Channel interface card
    Figure 5. Fibre Channel interface card

    IBM FlashSystem 840 supports the 16 Gbps Fibre Channel connection speed through the standard Fibre Channel interface card.

    Here are the rules for supporting 16 Gbps Fibre Channel on IBM FlashSystem 840:
    • If you use 16 Gbps Fibre Channel, only two (of the four) ports on the Fibre Channel modules can be used. The two left-most ports (1 and 2) on each interface card are used for 16 Gbps support. If your system is configured for 16 Gbps Fibre Channel, only the 2 left-most ports (1 and 2) per interface adapter are used. The other two ports are disabled.
    • If you use 16 Gbps Fibre Channel, all four of the Fibre Channel modules are configured for 16 Gbps. This configuration supports a total of eight Fibre Channel ports for the system (2 ports x 4 interface cards).
    • Four Gbps and 8 Gbps Fibre Channel connections are supported on the same system connecting to 16 Gbps devices, but there are still only a total of eight available active ports (ports 1 and 2 on each interface card). For example, an IBM FlashSystem 840 system can have four Fibre Channel connections at 16 Gbps and four Fibre Channel connections at 8 Gbps.
    • Fibre Channel interfaces support Fibre Channel Protocol (FCP) only, with point-to-point (FC-P2P), arbitrated loop (FC-AL), and switched fabric (FC-SW) topologies. FC interfaces can be configured as N_port or NL_port types. It should be noted that FC-AL is not supported for ports connected at 16 Gbps.
    • Full active-active multipathing across all interfaces is supported. Host software support for this function might vary.

    Fibre Channel over Ethernet support

    FlashSystem 840 supports 16 ports of 10 Gbps Fibre Channel over Ethernet. FCoE uses the same interface cards as FC.

    Fibre Channel and FCoE Interface Cards
    Each FlashSystem 840 canister supports two Fibre Channel (FC) interface cards for a total of four FC interface cards, 8 Gbps FC cards support four ports, 16 Gbps cards support two ports.

    Table 2 shows the supported interface cards.

    Table 2. FC/FCoE supported interface cards
    ItemFeature codePorts
    FC/FCoE Host Interface CardAF15
    Corequisites:
    AF18, AF19, or AF1A
    -Up to 16 ports of 8 Gbps Fibre Channel (with AF18)
    -Up to eight ports of 16 Gbps Fibre Channel (with AF19)
    -Up to 16 ports of 10 Gbps Fibre Channel over Ethernet (with AF1A)
    8 Gb FC 8 Port Host OpticsAF18Up to 16 ports of 8 Gbps Fibre Channel
    16 Gb FC 4 Port Host OpticsAF19Up to eight ports of 16 Gbps Fibre Channel
    10 Gb FCoE 8 Port Host OpticsAF1AUp to 16 ports of 10 Gbps Fibre Channel over Ethernet

    iSCSI interface card
    FlashSystem 840 supports 16 ports of 10 Gbps iSCSI for clients looking for alternatives to SANs. The iSCSI interface card looks similar to the FC/FCoE cards with Fibre optical connections as shown in the previous Figure 5.

    Table 3 shows the supported iSCSI interface card and port optics.

    Table 3. iSCSI supported interface cards
    ItemFeature codePorts
    iSCSI Host Interface CardAF17 (Corequisite : AF1D)Up to 16 ports of 10 Gbps iSCSI
    10 Gb iSCSI 8 Port Host OpticsAF1D Up to 16 ports of 10 Gbps iSCSI

    InfiniBand interface card

    IBM FlashSystem 840 supports four two-port InfiniBand 40 Gbps cards. A total of eight ports of 40 Gbps InfiniBand connections are supported per IBM FlashSystem 840.

    IBM FlashSystem 840 InfiniBand cards each have two 4X QDR ports. The InfiniBand card ports can connect to Quad Data Rate (QDR), Double Data Rate (DDR), or Single Data Rate (SDR) InfiniBand HCAs by using the SCSI RDMA Protocol (SRP). IBM FlashSystem 840 InfiniBand interfaces support SCSI RDMA Protocol (SRP) only.

    Table 4 lists the supported InfiniBand interface card.

    Table 4. Supported InfiniBand interface card
    ItemFeature codePorts
    QDR IB 4 Port Host Interface CardAF16Eight ports of 40 Gbps QDR InfiniBand

    Flash modules

    FlashSystem 840 provides configurable flash module capacity. All modules are hot-swappable.

    FlashSystem 840 can be populated with up to 12 flash modules in increments of 2, 4, 6, 8,10, or 12. These modules can be either 1 TB, 2 TB, or 4 TB and cannot be intermixed. Capacity can be upgraded by purchasing the AF1B (1 TB), AF10 (2 TB), or AF11 (4 TB) flash module feature codes as MES upgrades. Here are the upgrade paths:
    • Using AF1B (1 TB)
      • RAID 0: Start with 2 TB and grow to 4 TB, 6 TB, 8 TB, 10 TB or 12 TB.
      • RAID 5: Start with 2 TB and grow to 4 TB, 6 TB, 8 TB, 10 TB.
    • Using AF10 (2 TB)
      • RAID 0: Start with 4 TB and grow to 8 TB, 16 TB, or 24 TB.
      • RAID 5: Start with 4 TB and grow to 12 TB or 20 TB.
    • Using AF11 (4 TB)
      • RAID 0: Start with 32 TB and grow to 48 TB.
      • RAID 5: Start with 8 TB and grow to 24 TB or 40 TB.

    Table 5 lists the supported flash modules.

    Table 5. Supported flash modules
    DescriptionFeature codeMaximum quantity supported
    1 TB eMLC Flash Module
    AF1B
    12
    2 TB eMLC Flash ModuleAF1012
    4 TB eMLC Flash ModuleAF1112

    For RAID 0, these configurations have capacity points of 2 TB, 4 TB, 6 TB, 8 TB, 10 TB, 12 TB, 16 TB, 20 TB, 24 TB, 32 TB, 40 TB, and 48 TB.

    For RAID 5, these configurations have capacity points of 2 TB, 4 TB, 6 TB, 8 TB, 10 TB, 12 TB, 16 TB, 20 TB, 24 TB, 32 TB, and 40 TB.

    IBM Variable Stripe RAID

    Variable Stripe RAID data protection is a unique, self-healing data protection that is managed independently by each flash controller on each flash module. With Variable Stripe RAID, every flash controller creates a striped data layout across its set of 10 chips similar to a 9+1 RAID 5 array with rotating parity. The Variable Stripe RAID stripe (page) size is 4 KB. When the Variable Stripe RAID algorithm detects a failure affecting one or more flash module in a RAID stripe, the following process happens:
    1. Data that is stored in the affected regions is reconstructed from the remaining data/parity elements in the stripe.
    2. All pages in the affected stripe, including the reconstructed data, are moved to reserved space (overprovisioned area).
    3. Subsequent requests for data in the affected stripe are directed to the new locations (now part of the normal storage area in the system).
    4. The original location of the affected stripe is added to the available overprovisioned area as a (n-1) + parity stripe. (For example, if the affected stripe was a 9+1 stripe, it becomes an 8+1 stripe.).

    No system-level rebuild process is necessary to maintain data protection or usable capacity after a failure caught by Variable Stripe RAID. Further more, the entire Variable Stripe RAID recovery process is automatic and transparent to the user and administrator, and typically takes place in less than a second. Variable Stripe RAID activities are not normally tracked in system logs, but the root causes of failures that are typically handled by Variable Stripe RAID-plane failures and block failures are tracked in system counters and reflected in the overall flash module and system health metrics.

    IBM Two-dimensional (2D) Flash RAID

    The combination of IBM Variable Stripe RAID and system-level RAID 5 protection across flash modules is called two-dimensional (2D) Flash RAID. Variable Stripe RAID automatically and transparently protects against partial or full flash chip failures within the flash module, with no downtime or maintenance required. System-level RAID 5 adds protection against complete flash module failure and enables hot-swappable flash modules. Additionally, all active components are redundant and hot-swappable with tool-less access from the front or back of the system, enhancing two-dimensional RAID protection.

    RAID 5 and RAID 0 support

    In RAID 5 or RAID 0 modes, up to 2048 logical volumes (sometimes referred to as LUNs) can be created in the system, with a minimum size of 1 MB and a maximum size of the full available system capacity. In RAID 0, failures of single flash modules containing data compromise system data integrity for logical volumes that are stored on those flash modules. Under the direction of the management module, RAID module field-programmable gate arrays (FPGAs) can coordinate data transfer between modules, for example, to rebuild the system-level RAID 5 data layout, if RAID 5 mode is active.

    Note: As of FlashSystem 840 release 1.3, before enabling RAID 0, you must submit a SCORE/RPQ to IBM. To submit a SCORE/RPQ, contact your IBM representative.

    Scalable configurations

    FlashSystem 840 can scale usable capacity from as low as 2 TB to as high as 48 TB in its compact 2U enclosure. With FlashSystem 840, many granular capacity points are possible due to the three choices in flash module capacity: 1 TB, 2 TB, and 4 TB. Flash modules can be added so that IT personnel can expand capacity to support changing needs for organizations and enterprises of all sizes. Capacity expansion does however require reformat of existing RAID 0 or RAID 5 arrays to include the new flash modules.

    FlashSystem 840 supports the RAID 0 configurations with the latest capacity points with the addition of 1 TB flash module listed in Table 6.

    Table 6. Supported FlashSystem RAID 0 configurations with latest FlashSystem 840 capacity points
    Capacity Selection (in TB)
    FlashSystem 840 initial release
    FlashSystem 840 current release
    2

    2 X 1 TB
    4
    2 X 2TB
    4 X 1 TB
    6

    6 X 1 TB
    8
    4 X 2 TB
    8 X 1 TB
    10

    10 X 1 TB
    12

    12 X 1 TB
    16
    8 X 2 TB
    8 X 2 TB
    20

    10 X 2 TB
    24
    12 X 2 TB
    12 X 2 TB
    32
    8 X 4 TB
    8 X 4 TB
    40

    10 X 4 TB
    48
    12 X 4 TB
    12 X 4 TB

    RAID 0 configurations provide a high degree of capacity utilization because no flash modules are used for either spare or parity. Data protection is provided by Variable Stripe RAID, however data is not protected against flash module failure.

    FlashSystem 840 supports the RAID 5 configurations with the latest capacity points with the addition of 1 TB modules listed in Table 7.


    Table 7. Supported FlashSystem RAID 5 configurations with latest FlashSystem 840 capacity points
    Capacity Selection (in TB)
    FlashSystem 840 initial release
    FlashSystem 840 current release
    2

    4 X 1 TB
    4
    4 X 2TB
    6 X 1 TB
    6

    8 X 1 TB
    8
    4 X 4 TB
    10 X 1 TB
    10

    12 X 1 TB
    12
    8 X 2 TB
    8 X 2 TB
    16

    10 X 2 TB
    20
    12 X 2 TB
    12 X 2 TB
    24
    8 X 4 TB
    8 X 4 TB
    32

    10 X 4 TB
    40
    12 X 4 TB
    12 X 4 TB


    RAID 5 configurations provide a high degree of redundancy with Variable Stripe RAID as well as a RAID 5 protection. RAID 5 data protection includes two flash modules dedicated as parity and hot spare.

    Small or large RAID 5 configurations

    The cost of using RAID 5 as compared to RAID 0 is capacity. A RAID 5 configuration uses one flash module as parity and one flash module as spare. Maximum capacity utilization for RAID 5 is provided using 12 flash modules.

    Depending on client needs, and if capacity expansion is expected over time, clients may consider initial RAID 5 configurations with 12 flash modules which provides the least capacity penalty for RAID 5 protection. In comparison small configurations using only four flash modules configured in RAID 5 cost half of the total capacity reserved for redundancy.

    Note: Different flash module sizes cannot be intermixed in the same IBM FlashSystem 840 chassis.

    Network cables

    FlashSystem 840 supports the network cables that are listed in Table 8.

    Table 8. Supported network cables
    DescriptionFeature codeMaximum quantity supported
    Fibre Channel cables (supported on Fibre Channel ports)
    1 m Fiber Cable (LC-LC)370016
    5 m Fiber Cable (LC-LC)370116
    InfiniBand cables (supported on InfiniBand ports)
    1 m IBM QSFP Cop IBA0RD8
    3 m IBM QSFP Cop IBA0RE8
    3 m IBM QSFP Opt QDR IB59898
    10 m IBM QSFP Opt QDR IB59908
    1 m Mlnx QSFP Cop FDR14 IBA2YG8
    3 m Mlnx QSFP Cop FDR14 IBA2YH8
    3 m Mlnx QSFP Opt FDR14 IBA2YL8
    10 m Mlnx QSFP Opt FDR14 IBA2YN8
    Power supplies
    1300W Power Supply for High Line Voltage, MT 9840/43 AE1AF1H2
    900W Standard Power Supply, MT 9840/43 AE1AF1M2


    Encryption

    FlashSystem 840 storage system provides support for AES-XTS 256 bit data-at-rest encryption when the Encryption Enablement Pack, feature AF14, is ordered.

    In addition FlashSystem 840 has the following functions
    • Hot Encryption Activation - Adding an encryption license to a previously initialized system
    • Encryption Re-key - Changing the encryption key on a previously initialized system

    Both of these operations can be done concurrently and do not cause loss of access to data. Both operations do require that you purchase the Feature Code AF14: Encryption Enablement Pack.

    It is recommended that if you are planning to implement either Hot Encryption Activation or Encryption Re-key, that you inform IBM support so they can monitor the operation

    For more information refer to the FlashSystem Knowledge Center version 1.3:
    http://ibm.co/1o0Z8br

    System management

    The management modules in FlashSystem 840 storage system are processor complexes in the canisters. The management modules are configured for active-passive redundancy. The management modules run a highly customized Linux-based operating system that coordinates and monitors all significant functions in the system.

    The management modules provide a Java based web interface, Secure Shell (SSH) access, and SNMP connectivity through external Ethernet interfaces. The web and SSH interfaces allow administrators to monitor system performance and health metrics, configure storage, and collect support data, among other features.

    IBM FlashSystem 840 includes the usage of the common IBM SAN Volume Controller CLI and the IBM SAN Volume Controller GUI, which is based on the IBM XIV® GUI. IBM FlashSystem 840 supports SNMP, email forwarding (SMTP), and syslog redirection for complete enterprise management access.

    The storage configuration includes defining logical units with capacities, access policies, and other parameters. No software needs to be installed on host computers to administer FlashSystem 840 beyond a web browser with Java support or a standard SSH client.


    Web interface

    Navigating the management tool is simple. You can hover the cursor over one of the five function icons on the left side of the window, which highlights the function icon and shows a list of options. You can then move the cursor to the wanted option and click it. The GUI has three main sections for navigating through the management tool:
    • Function Icons (left side)
    • Status bars (bottom)
    • Actions menu (upper left, or right-click the home page)

    To the right of the upper middle of the GUI is the function key for managing the security of the user that is logged in. In the upper right corner is the Help button, which provides information about licenses and gives access to the FlashSystem 840 information center.

    On the far left of the window are five function icons:
    • The Monitoring menu
    • The Volumes menu
    • The Hosts menu
    • The Access menu
    • The Settings menu

    At the bottom of the window are three status indicators. These indicators provide information about capacity usage, throughput in megabytes per second (MBps), IOPS, and the health status of the system.

    The management GUI is the primary tool to manage the system. Figure 6 shows the management GUI and the associated menu options.


    Figure 6. IBM FlashSystem 840 Management GUI

    As of release 1.3, additional FlashSystem 840 management software improvements make system management and performance health monitoring even more effective in FlashSystem's already intuitive GUI. Additional features include:
    • Three hundred days of performance data with span and zoom capability to better identify and research trends
    • Five predefined graphs showing System IOPS, Latency, Bandwidth, Total Port IOPS, and Queue Depth


    Performance menu overview

    You enter the FlashSystem 840 performance monitor by clicking Monitoring -> Performance. The first time after the browser window is opened system latency is displayed as shown in Figure 7.


    Figure 7. Improved GUI - Performance monitoring default window

    The horizontal part of the graph displays the time line. You can slide the time line to view the past. You can also adjust the granularity of the time line by selecting one hour, one day, one week, one month or all. All displays the year to date.

    Five performance charts can be reviewed from the graphs menu:
    • System IO:
    • The System I/O graph displays the average number of read, write, and total I/O requests per second (IOPS) over the sample period. Each request type (read, write and total) is represented by a different color line.
    • System Latency
    • The System Latency graph displays the average amount of time in milliseconds (ms) each read and write I/O request takes over the given sampling period. Each request type (read and write) is represented by a different color line.
    • System Bandwidth

    • The System Bandwidth graph displays the average number of megabytes per second (MBps) of read, write, total and rebuild bandwidth over the sample period. Each bandwidth type (read, write, total, and rebuild) is represented by a different color line. There is one line graph for each system that is selected.
    • Interface port Total IOPS

    • The Total Port IOPS graph displays average number of read, write, and total I/O requests per second (IOPS) over the sample period. There is one line on the graph for each port in each host adapter in each canister. Each adapter has a different color, and all four ports on an adapter have the same color.
    • Interface port Total Queue Depth

    • The Total Port Queue Depth graph displays the average number of operations of that type over the sample period. There is one line on the graph for each port in each host adapter in each canister. Each adapter has a different color, and all four ports on an adapter have the same color.
    Command-line interface

    The CLI provides support for the following tasks:
    • Managing users
    • Configuring event notifications
    • Configuring Call Home
    • Configuring network settings
    • Configuring hosts interface I/O ports
    • Configuring a logical unit (volume)
    • Setting access policies
    • Backing up configuration settings
    • Restoring configuration settings

    Supported platforms

    IBM FlashSystem 840 supports a wide range of operating systems (Windows Server 2003, 2008, and 2012, Linux, and IBM AIX®), hardware platforms (IBM System x®, IBM Power Systems™, and x86 servers not from IBM), HBAs, and SAN fabrics. For specific information, see the IBM System Storage Interoperation Center (SSIC):

    http://www.ibm.com/systems/support/storage/ssic/interoperability.wss


    Physical and electrical specifications

    FlashSystem 840 has the following physical, electrical, and environmental specifications:
    • Dimensions and weight
      • Width: 445 mm (17.5 in.) (19-inch rack standard)
      • Depth: 761 mm (29.96 in.)
      • Height: 86.2 mm (3.39 in.)
      • Weight: 17.69 kg (39 lb)
    • Air temperature
      • Operating: Minimum of 5°C (50°F) at 30.5 m below to 3,050 m above sea level (100 ft below to 10,000 ft above); Maximum rated up to 40°C (95°F) at 30.5 m below to 950 m above sea level, de-rated 1°C for each 225 m above 950 m up to 3050 m
      • Non-operating: -10°C to 50°C (14°F to 125°F)
    • Relative humidity
      • Operating: 20% - 80%
      • Non-operating: 10% - 90%
    • Electrical power
      • Voltage range: 100-240 V AC
      • Frequency: 50 - 60 Hz
    • Acoustical noise emission
      • 8.0 bels (idling)
      • 8.0 bels (operating)
    • Power consumption
      • 900 watts PSU, 625 watts RAID 5 typical operation, per 2U
      • 1300 watts PSU, 900 watts RAID 5 typical operation, per 2U

    Warranty information and upgrades

    IBM FlashSystem 840 is shipped with a one-year and a three-year warranty.

    Technical Advisor (TA) support is provided during the warranty period. The TA enhances end-to-end support for the client’s complex IT solutions. The TA uses an integrated approach for proactive, coordinated cross-team support to allow customers to maximize IT availability. TA support for FlashSystem is delivered remotely and includes a documented support plan, coordinated problem and crisis management, reporting on the client's hardware inventories and microcode levels, and consultation regarding FlashSystem microcode updates. The Technical Advisor conducts a Welcome Call with the client and provides a statement of work for this support.

    Flash media within IBM FlashSystem is covered in full for the duration of the warranty and maintenance period. The system is also Energy Star certified.

    IBM Global Financing

    IBM Global Financing offers competitive financing to credit-qualified customers and IBM Business Partners to assist them in acquiring IT solutions. Our offerings include financing for IT acquisition, including hardware, software, and services, from both IBM and other manufacturers or vendors, and commercial financing (revolving lines of credit, term loans, acquisition facilities, and inventory financing credit lines) for Business Partners. Offerings (for all customer segments: small, medium, and large enterprise), rates, terms, and availability can vary by country. Contact your local IBM Global Financing organization or visit the following website:

    http://www.ibm.com/financing


    IBM Global Financing offerings are provided through IBM Credit LLC in the United States, and other IBM subsidiaries and divisions worldwide to qualified commercial and government customers. Rates are based on a customer's credit rating, financing terms, offering type, equipment type, and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension, or withdrawal without notice.

    Financing solutions from IBM Global Financing can help your customers stretch their budget and affordably acquire the new product. But beyond the initial acquisition, our end-to-end approach to IT management can also help keep their technologies current, reduce costs, minimize risk, and preserve their ability to make flexible equipment decisions throughout the entire technology Lifecycle.

    Related publications and links

    For more information, see these resources:
    http://ibm.co/1o0Z8br

     

    Others who read this also read

    Special Notices

    The material included in this document is in DRAFT form and is provided 'as is' without warranty of any kind. IBM is not responsible for the accuracy or completeness of the material, and may update the document at any time. The final, published document may not include any, or all, of the material included herein. Client assumes all risks associated with Client's use of this document.