The IBM® System x3950 X6 server is an eight-socket 8U rack-mounted server that represents the sixth generation of the IBM Enterprise X-Architecture®. It delivers innovation with enhanced scalability, reliability, availability, and serviceability features to enable optimal performance for mission-critical databases, enterprise applications, and virtualized environments.

The x3950 X6 packs numerous fault-tolerant and high-availability features into a high-density, 8U rack-optimized lid-less package that helps to significantly reduce the space that is needed to support massive network computing operations and simplify servicing. The x3950 X6 supports up to eight Intel Xeon E7-8800 v2 high-performance processors and up to 12 TB of memory.

Changes in the April 22 update:
* GPUs and coprocessors now available as option part numbers
* SAP HANA Workload Optimized Models

Contents



Introduction

The IBM® System x3950 X6 server is an eight-socket 8U rack-mounted server that represents the sixth generation of the IBM Enterprise X-Architecture®. It delivers fast application performance, is based on an agile system design, and is a resilient platform that is needed for mission-critical databases, enterprise applications, and virtualized environments.

The x3950 X6 packs numerous fault-tolerant and high-availability features into a high-density, 8U rack-optimized lid-less package that helps reduce the space that is needed to support massive network computing operations and simplify servicing. The x3950 X6 supports up to eight Intel Xeon E7-8800 v2 high-performance processors and up to 12 TB of memory.

Suggested use: mission-critical scalable databases, business analytics, virtualization, enterprise applications, and cloud applications.

The following figure shows the IBM System x3950 X6.

The IBM System x3950 X6
Figure 1. The IBM System x3950 X6

Did you know?

The x3950 X6 server employs a lid-less design where all serviceable components are front- and rear-accessible. In addition, each major subsystem is implemented as modular "book" design, such as the Compute Books and I/O Books. This configuration means that components are easy to upgrade and service, which translates to greater uptime of applications to your users. The x3950 X6 offers enterprise scalability and advanced RAS features to support the most demanding mission-critical applications that require 24x7 operations.

Key features

The increasing demand for cloud-computing and analytics workloads by enterprises to meet social, mobile, and Big Data requirements drives innovation to find new ways to build informational systems. Clients are looking for cost-optimized fit-for-purpose IT solutions that manage large amounts of data, easily scale performance, and provide enterprise class reliability.

Built on decades of innovation, IBM introduces its sixth generation of Enterprise X-Architecture technology, IBM X6 servers. IBM X6 servers are fast, agile, and resilient:

  • Fast application performance means immediate access to actionable information.
  • Agile system design helps to reduce acquisition costs and provide the ability to upgrade processor and memory technology at each refresh within the same chassis.
  • Resilient platforms maximize application uptime and promote easy integration in virtual environments.

IBM X6 servers continue to lead the way as the shift toward mission-critical scalable databases, business analytics, virtualization, enterprise applications, and cloud-computing applications accelerates.

Fast application performance

The server offer numerous features to boost performance:
  • With eXFlash memory-channel storage, the server delivers up to 12.8 TB of ultra-low latency flash memory by using IBM WriteNow technology, which is ideal for high-performance applications.
  • Supports four, six, or eight E7-8800 v2 processors with 120 cores and 240 threads to maximize the concurrent running of multi-threaded applications.
  • Supports memory speeds up to 1600 MHz.
  • Supports up to 12 TB of memory in 192 DIMM sockets, with 24 DIMMs per processor.
  • Supports IBM memory-channel storage and IBM eXFlash DIMMs, where solid-state storage devices are installed in memory DIMM sockets. These devices are directly connected to the processors and provide the lowest latency values in the industry.
  • Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
  • Intel Hyper-Threading Technology boosts performance for multi-threaded applications by enabling simultaneous multi-threading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Intel Advanced Vector Extensions (AVT) improve floating-point performance for compute-intensive technical and scientific applications.
  • Supports a 12 Gbps SAS RAID portfolio.
  • The usage of solid-state drives (SSDs) instead of, or along with, traditional spinning drives (HDDs) can improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
  • PCI Express 3.0 I/O adapter slots that improve the theoretical maximum bandwidth by almost 100% (8 GTps per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GTps per link using 8b/10b encoding).
  • With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E7-4800/8800 v2 product families. This integration helps reduce I/O latency and increase overall system performance.
  • Support for up to four graphics processing units (GPUs) and co-processors to maximize computing power.
  • Energy-efficient electronic components help lower operational costs, including highly efficient 900 W AC and 1400 W AC power supplies with 80 PLUS Platinum certification.


Agile system design

The server provides many scalability and flexibility features:
  • Innovative module "book" design for each of the three subsystems: Compute Books, Storage Book, and I/O Books. Front and rear access means that you can easily scale the system by adding components without removing the entire server from the rack.
  • The modular book design also allows clients to create the configuration that fits their application and environment needs, which reduces acquisition costs while giving them the flexibility to grow and modify their configuration later.
  • The book design also means that subsystem upgrades are simpler, quicker to perform, and have a lower impact on the rest of the server.
  • Using 64 GB LRDIMMs, the server supports up to 12 TB of memory.
  • Up to 32 eXFlash DIMMs are supported for a total of 12.8 TB of low-latency and high-performance storage.
  • Up to 32x 1.8-inch eXFlash SSD bays, or up to 16x 2.5-inch bays, provide a flexible and scalable all-in-one platform to meet your increasing demands.
  • Offers up to 22 PCIe slots plus two dedicated Mezzanine LOM (ML2) adapter slots. Most slots are PCIe 3.0 to maximize I/O scalability.
  • PCIe slots are implemented in I/O Books to maximize modularity. Choose from Half-length I/O Books or Full-length I/O Books, depending on the adapters that you need to deploy.
  • Most components are common between the four-socket x3850 X6 and eight-socket x3950 X6, making for a simple upgrade path with minimal parts on the floor.


Resilient platform

The server provides many features to simplify serviceability and increase system uptime:
  • Upward Integration Modules for standard hypervisors enable the creation and management of policies to maintain high availability of virtual machines and concurrent updating of the system firmware, with no impact on application performance or availability.
  • Advanced Processor Recovery allows the system to automatically switch access and control of networking, management, and storage in the event of a processor 1 failure, providing higher availability and productivity.
  • Advanced Page Retire proactively protects applications from corrupted pages in memory, which is crucial for scaling memory to terabytes.
  • Redundant bit steering, memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
  • Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, which is protected from all other software running on a system.
  • Redundant Intel Platform Controller Hub (PCH) connections to the processors allow the platform to maintain access to networking, storage, and server management during a processor failure.
  • IBM eXFlash DIMMs support RAID 1 mirroring for data protection.
  • Hot-swap drives support RAID redundancy for data protection and greater system uptime.
  • Hot-swap I/O Books enabling you to install or replace adapters while the server is still running.
  • Tool-less lid-less design provides front and rear access for easy upgrades and serviceability. There is no need to pull the server out of the rack to access internal components.
  • Hot-swap power supplies and hot-swap dual-motor redundant fans provide availability for mission-critical applications.
  • A new LCD diagnostics panel that is combined with individual light path diagnostic LEDs quickly lead the technician to failed (or failing) components, which simplifies servicing, speeds up problem resolution, and helps improve system availability.
  • Predictive Failure Analysis (PFA) detects when system components (processors, memory, HDDs, SSDs, fans, and power supplies) operate outside of standard thresholds and generates proactive alerts in advance of a possible failure, therefore increasing uptime.
  • Built-in Integrated Management Module Version II (IMM2) continuously monitors system parameters, triggers alerts, and performs recovering actions in case of failures to minimize downtime.
  • Includes two special Mezzanine LOM (ML2) adapter slots with support for adapters with either two 10 Gb ports or 4 Gb ports. Supports direct connectivity to the IMM2 service processor for out-of-band systems management.
  • Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
  • Two integrated Trusted Platform Modules (TPMs) 1.2 support enables advanced cryptographic functionality, such as digital signatures and remote attestation.
  • Industry-standard Advanced Encryption Standard (AES) NI support for faster and stronger encryption.
  • IBM Systems Director® provides proactive systems management. It offers comprehensive systems management tools that help increase uptime, reduce costs, and improve productivity through advanced server management capabilities.
  • Solid-state drives (SSDs) offer better reliability than traditional mechanical HDDs for greater uptime.
  • Built-in diagnostic tests, using Dynamic Systems Analysis (DSA) Preboot, speed up troubleshooting tasks to reduce service time.
  • Three-year customer-replaceable unit and onsite limited warranty, 9x5 next business day. Optional service upgrades are available.

Locations of key components and connectors

The following figure shows the front of the x3950 X6 server.

Front view of the IBM System x3950 X6
Figure 2. Front view of the IBM System x3950 X6

The following figure shows the rear of the x3950 X6 server.

Rear view of the IBM System x3950 X6
Figure 3. Rear view of the IBM System x3950 X6

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications

ComponentsSpecification
Form factor8U rack
ProcessorUp to eight Intel Xeon E7-8800 v2 processors, each in a Compute Book. Each processor has either 15 cores (up to 2.8 GHz), 12 cores (up to 2.6 GHz), 10 cores (up to 2.2 GHz), eight cores (up to 2.0 GHz), or six cores (up to 3.4 GHz). There are three QPI links up to 8.0 GTps each. Up to 1600 MHz memory speed. Up to 37.5 MB L3 cache. Intel C602J chipset.
MemoryUp to 192 DIMM sockets (24 DIMMs per processor, installed in the Compute Book). RDIMMs and LRDIMMs (Load Reduced DIMMs) are supported, but memory types cannot be intermixed. Memory speed up to 1600 MHz.
Memory maximumsWith RDIMMs: Up to 3 TB with 192x 16 GB RDIMMs and eight processors.
With LRDIMMs: Up to 12 TB with 192x 64 GB LRDIMMs and eight processors.
Memory protectionECC, Chipkill, RBS, memory mirroring, and memory rank sparing.
Memory-channel storageOptional on all models. eXFlash DIMMs are installed in memory DIMM slots, but are seen by the OS as storage devices. Memory channels with eXFlash DIMMs must also have at least one RDIMM. Cannot be mixed with LRDIMMs. A maximum of 32 eXFlash DIMMs can be installed. Maximum 12.8 TB with 32x 400GB eXFlash DIMMs.
Disk drive baysUp to thirty-two 1.8-inch eXFlash SSD bays, or up to 16x eight 2.5-inch hot-swap SAS/SATA bays.
Maximum internal storage Up to 25.6 TB with 1.6 TB 2.5-inch SAS SSDs, or up to 19.2 TB with 1.2 TB 2.5-inch SAS HDDs, up to 16 TB with 1 TB 2.5-inch NL SAS/SATA HDDs, up to 12.8 TB with 400 GB 1.8-inch SATA SSDs.
RAID support12 Gb SAS/SATA RAID 0, 1, or 10 with ServeRAID M5210; optional upgrades to RAID 5 or 50 are available (zero-cache; 1 GB non-backed cache; 1 GB or 2 GB flash-backed cache). Upgrades to RAID 6 or 60 available for M5210 with 1 GB or 2 GB upgrades.
Optical and tape baysNone.
Network interfacesMezzanine LOM (ML2) slot for dual-port 10 GbE cards with SFP+ or RJ-45 connectors or quad-port GbE cards with RJ-45 connectors. See Table 2. Dedicated 1 GbE port for systems management.
PCI Expansion slots Up to 22 PCIe slots plus two dedicated Mezzanine LOM slots. The slots are as follows:
  • Four PCIe 3.0 x8 slots for internal RAID controllers (in two Storage Books)
  • Four PCIe 3.0 x16 slots (x16-wired), half length, full height (in two Primary I/O Books)
  • Two PCIe 3.0 x16 (x8-wired), half length, full height (in two Primary I/O Books)
  • Two ML2 slots for network adapter (PCIe 3.0 x8) (in two Primary I/O Books)
  • Four optional I/O Books, each with three slots, all full height (using two requires 6 processors; using all four requires 8 processors). Optional books are hot-swap capable.
Optional I/O Books can be either of the following options:
  • Half-length I/O Book: Two PCIe 3.0 x8 slots, one PCIe 3.0 x16 slot.
  • Full-length I/O Book: Two PCIe 3.0 x16, one PCIe 2.0 x4 slot; two aux power connectors: 150 W and 75 W. Supports one double-wide GPU up to 300 W.
PortsFront: Four USB 3.0, two USB 2.0, and one DB-15 video ports. Rear: Eight USB 2.0, one DB-15 video, one DB-9 serial, and one 1 GbE RJ-45 IMM2 systems management. Internal: two USB 2.0 port for embedded hypervisor. The second video IMM2 and internal USB hypervisor ports are used only when the server is partitioned into two four-socket servers.
CoolingIBM Calibrated Vectored Cooling™. Up to 20 redundant hot-swap fan packs and 10 fan zones with N+1 fan redundancy. Each fan pack includes two counter-rotated dual-motor fans.
Power supplyUp to eight redundant hot-swap 900 W AC or 1400 W AC power supplies (all 80 PLUS Platinum certified). -48 V 750 W DC power supplies are available through CTO.
Hot-swap partsDrives, power supplies, fans, and optional I/O Books.
VideoMatrox G200eR2 with 16 MB memory that is integrated into the IMM2. Maximum resolution is 1600 x 1200 at 75 Hz with 16 M colors.
Security featuresPower-on password, admin password, and four Trusted Platform Modules (TPMs).
Systems management UEFI, IBM Integrated Management Module II (IMM2) with remote presence feature, Predictive Failure Analysis, Light Path Diagnostics, Automatic Server Restart, IBM Systems Director and Active Energy Manager™, and IBM ServerGuide.
Operating systems supported Microsoft Windows Server 2012 R2, 2012, and 2008 R2, Red Hat Enterprise Linux 6, SUSE Linux Enterprise Server 11, and VMware vSphere ESXi 5.1 and 5.5.
Limited warranty Three-year customer-replaceable unit (CRU) and onsite limited warranty with 9x5 next business day (NBD).
Service and supportOptional service upgrades are available through IBM ServicePac® offerings: 4-hour or 2-hour response time, 8-hour fix time, 1-year or 2-year warranty extension, and remote technical support for IBM hardware and some IBM / OEM applications.
DimensionsHeight: 351 mm (13.7 in.), width: 482 mm (19.0 in.), depth: 804 mm (31.6 in.), depth with Full-length I/O Book installed: 903 mm (35.5 in.).
WeightMinimum configuration: 84.5 kg (186.3 lb), typical: 88.2 kg (194.5 lb), maximum: 110.0 kg (242.6 lb)

The server is shipped with the following items:
  • Statement of Limited Warranty
  • Important Notices
  • Rack Installation Instructions
  • Documentation CD that contains the Installation and Service Guide
  • IBM Systems Director Flyer
  • IBM System x® Rail Kit
  • 2.8 m (9.18 ft) C13-C14 power cord (one for each power supply)

Standard models

The following table lists the standard models.

Table 2. Standard models

Model†Intel Xeon Processor**
(in a Compute Book)
MemoryeXFlash
DIMMs
RAIDDrive bays
Drives
Ethernet‡
(ML2 slot)
I/O
slots§
Power
supplies
3837-BAx4x Xeon E7-8850 v2
12C 2.3GHz 24MB 105W
8x 8GB
1600MHz
Optional1x M52104x 2.5" HS / 16
Open bay
4x 1 GbE12 / 244x 900W
HS / 8
3837-CAx4x Xeon E7-8870 v2 15C
2.3GHz 30MB 130W
8x 8GB
1600MHz
Optional1x M52104x 2.5" HS / 16
Open bay
4x 1 GbE12 / 244x 900W
HS / 8
3837-CCx4x Xeon E7-8890 v2 15C
2.8GHz 37.5MB 155W
8x 8GB
1600MHz
Optional1x M52104x 2.5" HS / 16
Open bay
4x 1 GbE12 / 244x 900W
HS / 8
† x in the Machine Type Model (MTM) represents a country-specific letter (for example, the EMEA MTM is 3837-BAG, and the US MTM is 3837-BAU). Ask an IBM representative for specifics.
** Processor detail: Processor quantity and model, cores, core speed, L3 cache, and TDP.
‡ All models include one Intel I350-T4 ML2 Quad Port GbE Adapter adapter (I350-AM4 based).
§ Models with 12 slots have two Primary I/O Books (each with four slots) and two Storage Books (each with two slots) standard.

For more information about the standard features of the server, see the "Specifications" section.

SAP HANA Workload Optimized Solution models

The IBM System x3950 X6 Workload Optimized Solutions for SAP HANA provide optimal solutions for SAP NetWeaver Business Warehouse, data mart, and SAP Business Suite, Powered by SAP HANA applications. Preconfigured workload optimized server models for SAP HANA applications are configured with up to 2 TB of memory and are upgradeable to support larger single node and scale-out cluster implementations. These models include IBM General Parallel File System (GPFS) Single Server for x86 Integrated Offerings with 3-year software subscription and support.

The following table lists the Workload Optimized Solution models for SAP HANA.

Table 3. Workload Optimized Solution models for SAP HANA

ModelIntel Xeon Processor
(in a Compute Book)
MemoryRAIDDrive bays
Drives
EthernetI/O
slots
Power
supplies
3837-
HBx
4x E7-8880 v2 15C
2.5GHz 37.5MB
1600 MHz 130W
512 GB
32x 16 GB
RDIMM
1x M5210
+ upgrades*
8x 2.5” HS
6x 1.2 TB SAS HDD
2x 400 GB S3700 SSD
2x 4x1GbE ML2
2x Mellanox 10Gb*
12 std
24 max
8x 1400W
HS / 8
3837-
HCx
4x E7-8880 v2 15C
2.5GHz 37.5MB
1600 MHz 130W
1024 GB
32x 32 GB
LRDIMM
2x M5210
+ upgrades*
16x 2.5” HS
12x 1.2 TB SAS HDD
4x 400 GB S3700 SSD
2x 4x1GbE ML2
2x Mellanox 10Gb*
12 std
24 max
8x 1400W
HS / 8
3837-
HDx
8x E7-8880 v2 15C
2.5GHz 37.5MB
1600 MHz 130W
2048 GB
64x 32 GB
LRDIMM
2x M5210
+ upgrades*
16x 2.5” HS
12x 1.2 TB SAS HDD
4x 400 GB S3700 SSD
2x 4x1GbE ML2
2x Mellanox 10Gb*
18 std
24 max
8x 1400W
HS / 8
* See the list of specific components below

Each of these HANA models include the following components
  • One (model HBx) or two (HCx, HDx) ServeRAID M5210 controller (46C9110) with 2GB cache upgrade with flash backup (46C9110) plus Performance Accelerator (47C8710) and SSD Caching Enabler (90Y4318)
  • Six (HBx) or 12 (HCx, HDx) IBM 1.2TB 10K 6Gbps SAS 2.5" G3HS HDD (00AJ146)
  • Two (HBx) or four (HCx, HDx) S3700 400GB SATA 2.5" MLC G3HS Enterprise SSD for IBM System x (00AJ161)
  • Two Intel I350-T4 ML2 Quad Port GbE Adapter for IBM System x (00D1998)
  • Two Mellanox ConnectX-3 40GbE / FDR IB VPI Adapters (00D9550)
  • Four IBM SFP+ SR Transceiver (46C3447)
  • Four Mellanox QSA Adapter (QSFP to SFP+) (90Y3842)
  • Model HDx only: Two X6 Half-length I/O Books (44X4049)
  • IBM Systems solution for SAP HANA media
  • License for IBM General Parallel File System (GPFS) Single Server for x86 Integrated Offerings with 3-year software subscription and support

Note: The operating system software is not included with the SAP HANA models. Operating system selection must be a separate line item included in order: SLES for SAP with standard or priority support. The SAP HANA Software is included, but the license is sold separately by SAP or an SAP business partner. VMware Enterprise Plus license sold separately.

For more information about the standard features of the server, see the "Specifications" section.

Processor options

The x3950 X6 supports up to eight Intel Xeon E7-8800 v2 processors. Processors are installed in Compute Books, one processor in each Compute Book. The following figure shows the components of the Compute Book:

  • One processor
  • A total of 24 DIMM slots, 12 on each side of the book
  • Two hot-swap dual-motor fans that are mounted on the front of the book

The x3950 X6 supports four, six, or eight Compute Books. Other combinations are not supported.

Each Compute Book is installed in the front of the server, as shown in the following figure.

Compute Book
Figure 4. Compute Book

The following table shows the processor options. Each option includes the processor installed in a Compute Book.

Note: Compute Books with E7-4800 v2 processors are supported only in a four-socket x3850 X6 server and cannot be used in an x3950 X6 server.

The table also shows the maximum memory bus speed each processor supports plus which server models have each processor standard. If there is no corresponding where-used model for a particular processor, this processor is only available through CTO.

Table 3. Processor options
Part numberFeature
code
Description
(processor installed in a Compute Book)
Memory bus
speed (RAS /
Performance)†
Supported
quantities
x3950 X6
x3950 X6
models
where used
Intel Xeon E7-8800 v2 processor family (also supported in x3850 X6)
44X4001A4BBX6 Compute Book Intel Xeon E7-8850 v2 12C 2.3GHz 105W1600 / 1066 MHz4, 6, 8BAx
44X4031A4BHX6 Compute Book Intel Xeon E7-8857 v2 12C 3.0GHz 130W1600 / 1333 MHz4, 6, 8-
44X4011A4BDX6 Compute Book Intel Xeon E7-8870 v2 15C 2.3GHz 130W1600 / 1333 MHz4, 6, 8CAx
44X4016A4BEX6 Compute Book Intel Xeon E7-8880 v2 15C 2.5GHz 130W1600 / 1333 MHz4, 6, 8-
44X4036A4BJX6 Compute Book Intel Xeon E7-8880L v2 15C 2.2GHz 105W1600 / 1333 MHz4, 6, 8-
44X4021A4BFX6 Compute Book Intel Xeon E7-8890 v2 15C 2.8GHz 155W1600 / 1333 MHz4, 6, 8CCx
44X4026A4BGX6 Compute Book Intel Xeon E7-8891 v2 10C 3.2GHz 155W1600 / 1333 MHz4, 6, 8-
44X4006A4BCX6 Compute Book Intel Xeon E7-8893 v2 6C 3.4GHz 155W1600 / 1333 MHz4, 6, 8-
† The processors support two memory modes, RAS mode (also known as lockstep mode) and Performance mode (also known as independent mode). In Performance mode, the SMI2 link operates at twice the memory bus speed shown.

Memory options

IBM DDR3 memory is compatibility tested and tuned for optimal IBM System x® performance and throughput. IBM memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime. From a service and support standpoint, IBM memory automatically assumes the IBM system warranty, and IBM provides service and support worldwide.

The x3950 X6 supports DDR3 memory operating at speeds up to 1600 MHz. The server supports up to 192 DIMMs when all eight processors are installed, 24 DIMMs per processor. Each processor has four memory channels that are implemented using Scalable Memory Interface generation 2 (SMI2) chips, and the server implements three DIMMs per channel. The processor and the corresponding memory DIMM slots are on the Compute Book.

The following table lists the memory options that are available for x3950 X6.

Table 4. Memory options

Part numberFeature codeDescriptionMaximum
supported
x3950 X6
Standard models
where used
RDIMMs
00D5024A3QE4GB (1x4GB, 1Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM192 (24 per CPU)-
00D5036A3QH8GB (1x8GB, 1Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM192 (24 per CPU)BAx, CAx, CCx
46W0672A3QM16GB (1x16GB, 2Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM192 (24 per CPU)-
LRDIMMs
46W0676A3SR32GB (1x32GB, 4Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP LRDIMM192 (24 per CPU)-
46W0741A45164GB (1x64GB, 8Rx4, 1.35V) PC3-10600 DDR3 1333MHz LP LRDIMM192 (24 per CPU)-

The following rules apply when selecting the memory configuration:
  • The server supports RDIMMs and LRDIMMs.
  • Mixing different types of memory (RDIMMs and LRDIMMs) is not supported.
  • The maximum number of ranks per one DDR3 channel is six with RDIMMs or 24 with LRDIMMs.
  • In RAS (lockstep) mode, DIMMs must be installed in a pair.
  • The maximum quantity of DIMMs that can be installed in the server depends on the number of processors, DIMM type, rank, and operating voltage, as shown in the "Max. qty supported" row in the following table.
  • All DIMMs in the server operate at the same speed, which is determined as the lowest value of one of the following options:
    • Memory speed that is supported by the specific processor.
    • Lowest of maximum operating speeds for selected memory configuration that depends on rated speed, operating voltage, and quantity of DIMMs per channel, as shown under "Maximum operating speed" section in the following table.
  • The server also supports IBM eXFlash DIMMs, which are also installed in the DIMM slots. The "IBM eXFlash memory-channel storage" section describes these eXFlash DIMMs and the configuration rules.

The following table shows the characteristics of the supported DIMMs. Tables cells that are highlighted with a gray background indicate that the server supports higher memory frequencies or larger memory capacity (or both) than the Intel processor specification defines.

Memory speed: In performance mode, memory channels operate independently, and the SMI2 link operates at twice the DDR3 speed. In RAS mode, two channels operate synchronously, and the SMI2 link operates at the DDR3 speed.

Table 5. Maximum memory speeds
DIMM
specification
RDIMM
LRDIMM
Rank
Single rank
Dual rank
Quad rank
8-rank
Part numbers
00D5024 (4GB)
00D5036 (8GB)
46W0672 (16GB)
46W0676 (32GB)
46W0741 (64GB)
Rated speed
1600 MHz
1600 MHz
1600 MHz
1333 MHz
Rated voltage
1.35 V
1.35 V
1.35 V
1.35 V
Operating voltage
1.35 V
1.5 V
1.35 V
1.5 V
1.35 V
1.5 V
1.35 V
1.5 V
Max qty supported*
192
192
192
192
192
192
192
192
Max DIMM capacity
8 GB
8 GB
16 GB
16 GB
32 GB
32 GB
64 GB
64 GB
Max memory capacity
1.5 TB
1.5 TB
3.0 TB
3.0 TB
6 TB
6 TB
12 TB
12 TB
Maximum operating speed - Performance mode (2:1 mode - SMI2 link operates at twice the DDR3 speed shown)
1 DIMM per channel
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
2 DIMMs per channel
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
3 DIMMs per channel
1066 MHz
1333 MHz
1066 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
Maximum operating speed - RAS mode (1:1 mode - SMI2 link operates at the DDR3 speed shown)
1 DIMM per channel
1333 MHz
1600 MHz
1333 MHz
1600 MHz
1333 MHz
1600 MHz
1333 MHz
1333 MHz
2 DIMMs per channel
1333 MHz
1600 MHz
1333 MHz
1600 MHz
1333 MHz
1600 MHz
1333 MHz
1333 MHz
3 DIMMs per channel
1066 MHz
1333 MHz
1066 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
* Maximum quantity supported is shown for all processors installed.

The following memory protection technologies are supported:
  • ECC
  • Chipkill (for x4-based memory DIMMs)
  • Redundant bit steering (Double Device Data Correction)
  • Memory mirroring
  • Memory rank sparing

Chipkill and Redundant Bit Steering are supported in RAS mode. Chipkill is supported in Performance mode.

If memory mirroring is used, DIMMs must be installed in pairs for Performance mode (minimum of one pair per each processor) and quads for RAS mode. DIMMs in the pair/quad must be identical in type and size.

If memory rank sparing is used, then a minimum of two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need being identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs that are installed.

IBM eXFlash memory-channel storage

IBM eXFlash memory-channel storage are storage offerings in the physical form of memory DIMMs. These IBM eXFlash DIMMs are installed in memory DIMM sockets but appear to the operating system and applications as block storage devices. This new and innovative technology brings storage electrically closer to the processor subsystem, therefore improving performance considerably.

Note: Both the x3850 X6 and the x3950 X6 support at most 32 eXFlash DIMMs.

The following table shows the supported eXFlash DIMMs.

Table 6. Internal storage expansion options

Part numberFeature
code
Name and descriptionMaximum
supported
x3950 X6
00FE000A4GXIBM eXFlash 200GB DDR3 Storage DIMM32
00FE005A4GYIBM eXFlash 400GB DDR3 Storage DIMM32

The following figure shows one eXFlash DIMM installed with RDIMMs in the Compute Book.

IBM eXFlash DIMM installed in the Compute Book
Figure 5. IBM eXFlash DIMM installed in the Compute Book

The following rules apply when building a server configuration with eXFlash DIMMs:
  • The 200 GB and 400 GB eXFlash DIMMs cannot be mixed.
  • RAID 1 mirroring is provided by the eXFlash DIMM device driver.
  • Performance memory mode must be selected. RAS (lockstep) memory mode is not supported.
  • Only RDIMMs are supported by eXFlash DIMMs; LRDIMMs are not supported
  • eXFlash DIMMs can only installed on the Compute Books in the lower half of the server (processors 1-4)
  • The maximum quantities of eXFlash DIMMs are as follows:
    • Four processors: 16 eXFlash DIMMs
    • Six processors: 24 eXFlash DIMMs
    • Eight processors: 32 eXFlash DIMMs

Internal storage

The server supports 1.8-inch solid-state drives in the IBM eXFlash SSD units and 2.5-inch SSDs and HDDs. Drives are installed in the Storage Book. The x3950 X6 has two Storage Books. The Storage Book supports the following configurations:

  • 4x 2.5-inch hot-swap drive bays
  • 8x 2.5-inch hot-swap drive bays
  • 4x 2.5-inch hot-swap drive bays + 8x 1.8-inch hot-swap SSD bays
  • 8x 1.8-inch hot-swap SSD bays
  • 16x 1.8-inch hot-swap SSD bays

The following figure shows these configurations.

Internal drive configurations
Figure 6. Internal drive configurations

Backplanes

All standard models ship with four 2.5-inch SAS/SATA hot-swap hard disk drive bays. The following table shows the internal storage expansion options that are available.

Table 7. Internal storage expansion options
Part
number
Feature
code
DescriptionMaximum
supported
x3950 X6
44X4104A4A6IBM 4x 2.5" HS 12Gb SAS HDD Backplane4
44X4106A4A7IBM 8x 1.8" HS 12Gb SAS HDD Backplane4

The backplanes are connected to one or two RAID controllers or HBAs depending on the number and type of backplane that is installed. The adapters are installed in PCIe slots in the Storage Book, as shown in the following figure.

Storage Book
Figure 7. Storage Book

The following table shows the backplanes that are required per Storage Book and the number of adapters that are required.

Table 8. Drive combinations per Storage Book
Drive combinationBackplanes requiredControllers
needed
4x 2.5-inch hot-swap drive bays1x IBM 4x 2.5" HS 12Gb SAS HDD Backplane, 44X41041
8x 2.5-inch hot-swap drive bays2x IBM 4x 2.5" HS 12Gb SAS HDD Backplane, 44X41041 or 2
4x 2.5-inch hot-swap drive bays +
8x 1.8-inch hot-swap SSD bays
1x IBM 4x 2.5" HS 12Gb SAS HDD Backplane, 44X4104
1x IBM 8x 1.8" HS 12Gb SAS HDD Backplane, 44X4106
2
8x 1.8-inch hot-swap SSD bays1x IBM 8x 1.8" HS 12Gb SAS HDD Backplane, 44X41061
16x 1.8-inch hot-swap SSD bays2x IBM 8x 1.8" HS 12Gb SAS HDD Backplane, 44X41062

Controllers for internal storage

The following table lists the RAID controllers, HBAs, and additional hardware and feature upgrades that are used for internal disk storage. The adapters are installed in slots in the Storage Book.

Table 9. RAID controllers and HBAs for internal storage

Part numberFeature codeDescriptionMaximum
supported
x3950 X6
Where
used
46C9110A3YZServeRAID M5210 SAS/SATA Controller4All models
47C8675A3YYN2215 SAS/SATA HBA for IBM System x4-
Hardware upgrades for the ServeRAID M5210
47C8656A3Z0ServeRAID M5200 Series 1GB Cache/RAID 5 Upgrade4-
47C8660A3Z1ServeRAID M5200 Series 1GB Flash/RAID 5 Upgrade4-
47C8664A3Z2ServeRAID M5200 Series 2GB Flash/RAID 5 Upgrade4-
Features on Demand upgrades for the ServeRAID M5210
47C8708A3Z6ServeRAID M5200 Series Zero Cache/RAID 5 Upgrade2-
47C8706A3Z5ServeRAID M5200 Series RAID 6 Upgrade2*-
47C8710A3Z7ServeRAID M5200 Series Performance Accelerator2*-
47C8712A3Z8ServeRAID M5200 Series SSD Caching Enabler2*-
* These M5210 features upgrades require a cache memory upgrade (47C8656, 47C8660, or 47C8664).

The ServeRAID M5210 SAS/SATA Controller has the following specifications:
  • Eight internal 12 Gbps SAS/SATA ports
  • Two x4 HD mini-SAS internal connectors (SFF-8643)
  • Supports connections to SAS/SATA drives and SAS Expanders
  • Supports RAID 0, 1, and 10
  • Supports RAID 5 and 50 with optional M5200 Series RAID 5 upgrades
  • Supports RAID 6 and 60 with the optional M5200 Series RAID 6 Upgrade
  • Supports 1 GB non-backed cache or 1 GB or 2 GB flash-backed cache
  • Up to 12 Gbps throughput per port
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS3108 12 Gbps ROC controller

The IBM N2215 SAS/SATA HBA has the following specifications:
  • Eight internal 12 Gbps SAS/SATA ports
  • Two x4 HD mini-SAS internal connectors (SFF-8643)
  • Supports connections to SAS/SATA HDDs and SATA SSDs
  • Optimized for SSD performance
  • No RAID support
  • Up to 12 Gbps throughput per port
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS3008 12 Gbps controller

For more information, see the list of IBM Redbooks® Product Guides in the RAID adapters category at the following address:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=raid

Internal drive options

The following table lists hard disk drive options for internal storage.

Table 10. Disk drive options for internal disk storage

Part
number
Feature
code
DescriptionMaximum
supported
x3950 X6
1.8" SATA HS SSDs
41Y8366A4FSS3700 200GB SATA 1.8" MLC Enterprise SSD32
41Y8371A4FTS3700 400GB SATA 1.8" MLC Enterprise SSD32
2.5" SAS HS SSDs
00AJ207A4UAIBM 200GB SAS 2.5" MLC G3HS Enterprise SSD16
00AJ212A4UBIBM 400GB SAS 2.5" MLC G3HS Enterprise SSD16
00AJ217A4UCIBM 800GB SAS 2.5" MLC G3HS Enterprise SSD16
00AJ222A4UDIBM 1.6TB SAS 2.5" MLC G3HS Enterprise SSD16
2.5" SATA HS SSDs
00AJ156A4U3S3700 200GB SATA 2.5" MLC G3HS Enterprise SSD16
00AJ161A4U4S3700 400GB SATA 2.5" MLC G3HS Enterprise SSD16
00AJ166A4U5S3700 800GB SATA 2.5" MLC G3HS Enterprise SSD16
2.5" NL SAS HS HDDs
00AJ121A4TTIBM 500GB 7.2K 6Gbps NL SAS 2.5" G3HS HDD16
00AJ086A4TUIBM 1TB 7.2K 6Gbps NL SAS 2.5'' G3HS HDD16
2.5" NL SATA HS HDDs
00AJ131A4TVIBM 250GB 7.2K 6Gbps NL SATA 2.5" G3HS HDD16
00AJ136A4TWIBM 500GB 7.2K 6Gbps NL SATA 2.5" G3HS HDD16
00AJ141A4TXIBM 1TB 7.2K 6Gbps NL SATA 2.5" G3HS HDD16
2.5" 15K SAS HS HDDs
00AJ081A4TRIBM 300GB 15K 6Gbps SAS 2.5" G3HS HDD16
00AJ111A4TQIBM 146GB 15K 6Gbps SAS 2.5" G3HS HDD16
2.5" 10K SAS HS HDDs
00AJ146A4TPIBM 1.2TB 10K 6Gbps SAS 2.5" G3HS HDD16
00AJ071A4TNIBM 900GB 10K 6Gbps SAS 2.5" G3HS HDD16
00AJ091A4TMIBM 600GB 10K 6Gbps SAS 2.5" G3HS HDD16
00AJ096A4TLIBM 300GB 10K 6Gbps SAS 2.5" G3HS HDD16
2.5" SAS HS SEDs
00AJ116A4U2IBM 146GB 15K 6Gbps SAS 2.5" G3HS SED16
00AJ106A4TYIBM 300GB 10K 6Gbps SAS 2.5" G3HS SED16
00AJ101A4TZIBM 600GB 10K 6Gbps SAS 2.5" G3HS SED16
00AJ076A4U0IBM 900GB 10K 6Gbps SAS 2.5" G3HS SED16
00AJ151A4U1IBM 1.2TB 10K 6Gbps SAS 2.5'' G3HS SED16

Internal backup units

The server does not support internal tape drive options.

Optical drives

The server does not support internal optical drives.

I/O expansion options

The server supports up to 22 PCIe slots plus two dedicated Mezzanine LOM slots (24 total) as follows:

  • In each of the two Storage Books (standard in all models): Two PCIe 3.0 x8 slots for supported internal RAID controllers and SAS HBAs
  • In each of the two Primary I/O Books (standard in all models):
    • Two PCIe 3.0 x16 slots (x16-wired), half length, full height, up to 75 W of power
    • One PCIe 3.0 x16 (x8-wired), half length, full height, up to 75 W of power
    • One mezzanine LOM 2 (ML2) slot for network adapters with the new ML2 form factor (PCIe 3.0 x8)
  • Four optional I/O Books, each with three slots, all full height. Optional I/O Books are hot-swap capable.

The following figure shows the Primary I/O Book with the air baffle raised to show the internals.

Primary I/O Book
Figure 8. Primary I/O Book

Optional I/O Books can be either of:
  • Half-length I/O Book:
    • Two PCIe 3.0 x8 slots (x8 wired)
    • One PCIe 3.0 x16 slot (x16 wired)
  • Full-length I/O Book:
    • Two PCIe 3.0 x16 (x16 wired)
    • One PCIe 2.0 x8 slot (x4 wired)

In order for an I/O Book to be hot-swappable, all adapters that are installed in the book must support hot-swap and the operating system must also support hot-swap. These operating systems support hot-swap:
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2

The adapters listed in the following table support hot-swap.

Table 11. Adapters that support hot swap
Part numberFeature codeDescription
00D8540A4XHEmulex Dual Port 10GbE SFP+ VFA IIIr for IBM System x
49Y7960A2ECIntel X520 Dual Port 10GbE SFP+ Adapter for IBM System x
49Y7970A2EDIntel X540-T2 Dual Port 10GBaseT Adapter for IBM System x
49Y42305767Intel Ethernet Dual Port Server Adapter I340-T2 for IBM System x
49Y42405768Intel Ethernet Quad Port Server Adapter I340-T4 for IBM System x

The use of two Optional I/O Books requires six processors to be installed. The usage of all four Optional I/O Books requires all eight processors to be installed.

The following table shows the ordering information for the optional I/O Books.

Table 12. I/O Book options
Part
number
Feature
code
DescriptionMaximum
supported
x3950 X6
44X4049A4A2X6 Half-Length I/O Book4
44X4051A4A3*X6 Full-Length I/O Book4
* The Full-length I/O Book can be ordered only as an option. It is not available through CTO because the Full-length I/O Book cannot be shipped installed in the server

The following figure shows the two optional I/O Books: the Half-length I/O Book and the Full-length I/O Book.

Half-length I/O Book and the Full-length I/O Book
Figure 9. Half-length I/O Book and the Full-length I/O Book

The following figure shows the Half-length I/O Book.

Half-length I/O Book
Figure 10. Half-length I/O Book

Each slot in the Half-length I/O Book and the Full-length I/O Book supplies up to 75 W of power.

The Full-length I/O Book also includes two auxiliary power connectors. With the usage of these connectors and the supplied power cords, the I/O book supports one double-wide adapter up to 300 W. The auxiliary power connectors are as follows:
  • One 2x4 power connector, which supplies up to 150 W of additional power to the adapter
  • One 2x3 power connector, which supplies up to 75 W of additional power to the adapter

The combined power consumption of all the adapters that are installed in the Full-length I/O Book cannot exceed 300 W.

Note: The 2x3 connector is intended to be used only when one adapter is installed in the first x16 slot (the up-most slot in the following figure), either requiring 225 W or 300 W of power. The location of the 2x3 connector prevents an adapter from being installed in the other x16 slot.

Full-length I/O Book
Figure 11. Full-length I/O Book

The Half-length I/O Book installs flush with the Primary I/O Book at the rear of the server. The Full-length I/O Book, when installed, adds a 99 mm (3.9 in.) mechanical extension to the base length dimension of the chassis.

The following figure shows a Full-length I/O Book and a Half-length I/O Book that are installed in the server.

Optional I/O Books installed (x3850 X6 shown)
Figure 12. Optional I/O Books that are installed (x3850 X6 shown)

Network adapters

The server supports ML2 adapters that are installed in the two ML2 slots, one in each Primary I/O Book. These ML2 slots support adapters with either two 10 Gb ports or four Gigabit ports and supports direct connectivity to the IMM2 service processor for out-of-band systems management.

As listed in Table 2, all standard models of the x3950 X6 include an Intel I350-T4 ML2 Quad Port GbE Adapter (I350-AM4 based).

The Intel I350-T4 ML2 Quad Port GbE Adapter has the following specifications:

  • Quad-port 1 Gb Ethernet connectivity
  • Intel I350-AM4 ASIC
  • Four RJ45 ports for copper cables

For more information about this adapter, see the IBM Redbooks Product Guide found at the following address:
http://www.redbooks.ibm.com/abstracts/tips1155.html?Open

The following table lists the supported ML2 adapters.

Table 13. ML2 adapters
Part numberFeature
code
DescriptionMaximum
supported
x3950 X6
00D2026A40SBroadcom NetXtreme II ML2 Dual Port 10GbaseT for IBM System x2
00D2028A40TBroadcom NetXtreme II ML2 Dual Port 10GbE SFP+ for IBM System x2
00D1996A40QEmulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter for IBM System x2
00D8544A4NZEmulex VFA5 ML2 FCoE/iSCSI License for IBM System x (FoD)
(Features on Demand upgrade for 00D1996 - one for each adapter)
2
00D1994A40PIntel X540 ML2 Dual Port 10GbaseT Adapter for IBM System x2
00D1998A40RIntel I350-T4 ML2 Quad Port GbE Adapter for IBM System x2

The server also supports various other Ethernet and InfiniBand network adapters, as listed in the following table. The maximum quantity listed is for configurations with all processors and I/O books installed.

Table 14. Network adapters
Part numberFeature
code
DescriptionMaximum
supported
x3950 X6
40 Gb Ethernet
00D9550A3PNMellanox ConnectX-3 40GbE / FDR IB VPI Adapter for IBM System x18
10 Gb Ethernet
49Y7910A18YBroadcom NetXtreme II Dual Port 10GBaseT Adapter for IBM System x18
00D8540A4M9Emulex Dual Port 10GbE SFP+ VFA III-R for IBM System x18
49Y7960A2ECIntel X520 Dual Port 10GbE SFP+ Adapter for IBM System x18
49Y7970A2EDIntel X540-T2 Dual Port 10GBaseT Adapter for IBM System x18
00D9690A3PMMellanox ConnectX-3 10 GbE Adapter for IBM System x18
42C18005751QLogic 10Gb CNA for IBM System x18
90Y4600A3MRQLogic 8200 Dual Port 10GbE SFP+ VFA for IBM System x18
47C9952A47HSolarflare SFN5162F 2x10GbE SFP+ Performant Adapter for IBM System x18
47C9960A47JSolarflare SFN6122F 2x10GbE SFP+ Onload Adapter for IBM System x18
Gigabit Ethernet
90Y9370A2V4Broadcom NetXtreme I Dual Port GbE Adapter for IBM System x18
90Y9352A2V3Broadcom NetXtreme I Quad Port GbE Adapter for IBM System x18
49Y42305767Intel Ethernet Dual Port Server Adapter I340-T2 for IBM System x18
49Y42405768Intel Ethernet Quad Port Server Adapter I340-T4 for IBM System x18
InfiniBand
00D9550A3PNMellanox ConnectX-3 40GbE / FDR IB VPI Adapter for IBM System x18

For more information, see the list of IBM Redbooks Product Guides in the Networking adapters category found at the following address:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=networkadapters

Storage host bus adapters

The following table lists storage HBAs supported by the server. The maximum quantity listed is for configurations with all processors and I/O books installed. The maximum quantity listed is for configurations with all processors and I/O books installed.

Table 15. Storage adapters

Part numberFeature
code
DescriptionMaximum
supported
x3950 X6
Fibre Channel - 16 Gb
81Y1655A2W5Emulex 16Gb FC Single-port HBA for IBM System x18
81Y1662A2W6Emulex 16Gb FC Dual-port HBA for IBM System x18
81Y1668A2XUBrocade 16Gb FC Single-port HBA for IBM System x18
81Y1675A2XVBrocade 16Gb FC Dual-port HBA for IBM System x18
00Y3337A3KWQLogic 16Gb FC Single-port HBA for IBM System x18
00Y3341A3KXQLogic 16Gb FC Dual-port HBA for IBM System x18
Fibre Channel - 8 Gb
42D04853580Emulex 8 Gb FC Single-port HBA for IBM System x18
42D04943581Emulex 8 Gb FC Dual-port HBA for IBM System x18
42D05013578QLogic 8 Gb FC Single-port HBA for IBM System x18
42D05103579QLogic 8 Gb FC Dual-port HBA for IBM System x18
46M60493589Brocade 8 Gb FC Single-port HBA for IBM System x18
46M60503591Brocade 8 Gb FC Dual-port HBA for IBM System x18
SAS
46C9010A3MVN2125 SAS/SATA HBA for IBM System x18

For more information, see the list of IBM Redbooks Product Guides in the Host bus adapters category found at the following address:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=hba

PCIe SSD adapters

The server supports the High IOPS SSD adapters that are listed in the following table. The maximum quantity listed is for configurations with all processors and I/O books installed.

Table 16. SSD adapters

Part numberFeature codeDescriptionMaximum
supported
x3950 X6
46C9078A3J3IBM 365GB High IOPS MLC Mono Adapter18
46C9081A3J4IBM 785GB High IOPS MLC Mono Adapter18
90Y4377A3DYIBM 1.2TB High IOPS MLC Mono Adapter18
90Y4397A3DZIBM 2.4TB High IOPS MLC Duo Adapter18

For more information, about these adapters, see the IBM Redbooks Product Guide IBM High IOPS MLC Adapters, TIPS0907, found at the following address:
http://www.redbooks.ibm.com/abstracts/tips0907.html?Open

GPU adapters

The server supports the co-processors and graphics processing units (GPUs) that are listed in the following table. Each is installed in a Full-length I/O Book. No other adapter can be installed in the Full-length I/O Book. The Full-length I/O Book includes the necessary auxiliary power cables.

Note: These adapters are not available through CTO and cannot be shipped installed in the server because they are installed in the Full-length I/O Book, which extends beyond the rear of the chassis (see Figure 12). These adapters must be shipped separately from the server. Order the adapter and Full-length I/O Book as separate options.

Table 17. GPU adapters

Part numberFeature codeDescriptionMinimum
system
RAM
Maximum
supported
x3950 X6
00FP670A4G4*Intel Xeon Phi 3120A PCIe x16 for System x3850/x3950 X612 GB4
00FP671A5U2*NVIDIA Grid K1 PCIe x16 for System x3850/x3950 X632 GB4
00FP674A470*NVIDIA Grid K2 Actively Cooled PCIe x16 for System x3850/x3950 X616 GB4
00FP673A471*NVIDIA Tesla K20 Actively Cooled PCIe x16 for System x3850/x3950 X610 GB4
00FP676A5FG*NVIDIA Tesla K40c PCIe x16 for System x3850/x3950 X624 GB4
00FP675A3YU*NVIDIA Quadro K4000 PCIe x16 for System x3850/x3950 X66 GB4
00FP672A3YV*NVIDIA Quadro K6000 PCIe x16 for System x3850/x3950 X624 GB4
* Not available through CTO.

Power supplies

The x3950 X6 supports up to eight redundant power supplies. Standard models come with four power supplies (model dependent). The following table lists the power supplies.

Table 18. Power supplies

Part numberFeature
code
DescriptionMaximum
supported
x3950 X6
Standard models
where used
44X4150A54DIBM 1400W HE Redundant Power Supply
for altitudes >5000 meters
8All HANA models
44X4152A54EIBM 1400W HE Redundant Power Supply8-
44X4132A4R0IBM 900W Power Supply8BAx, CAx, CCx
88Y7433A2EAIBM 750W High Efficiency -48 V DC Power Supply8-

An AC power supply ships standard with one 2.8 m C13 - C14 power cord.

Integrated virtualization

The server supports VMware ESXi that is installed on a USB memory key. The key is installed in a USB socket that is on the primary I/O book inside the server. The following table lists the virtualization options.

Table 19. Virtualization options

Part numberFeature
code
DescriptionMaximum
supported*
41Y8298A2G0IBM Blank USB Memory Key for VMware ESXi Downloads1 / 2
41Y8382A4WZIBM USB Memory Key for VMware ESXi 5.1 U11 / 2
* 2 hypervisor keys are supported only if the x3950 X6 is configured to be partitioned, where the two halves of the server operate as two independent four-socket servers. However, CTO orders can include only one hypervisor key.

Systems management

The server contains IBM Integrated Management Module II (IMM2), which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. The IMM2 also provides a virtual presence capability for remote server management capabilities.

The IMM2 provides remote server management through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3
  • Common Information Model (CIM)
  • Web browser

The remote presence provides the following functions:
  • Remotely viewing video with graphics resolutions up to 1600 x 1200 at 75 Hz with up to 23 bits per pixel colors, regardless of the system state
  • Remotely accessing the server by using the keyboard and mouse from a remote client
  • Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
  • Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive

The blue-screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating-system hang condition. A system administrator can use the blue-screen capture feature to assist in determining the cause of the hang condition.

Supported operating systems

The server supports the following operating systems:

  • Microsoft Windows Server 2012 R2
  • Microsoft Windows Server 2012
  • Microsoft Windows Server 2008 R2
  • Red Hat Enterprise Linux 6 Server x64 Edition
  • SUSE Linux Enterprise Server 11 with Xen for AMD64/EM64T
  • SUSE Linux Enterprise Server 11 for AMD64/EM64T
  • VMware vSphere 5.5 (ESXi)
  • VMware vSphere 5.1 (ESXi)

For the latest information about the specific versions and service levels that are supported and any other prerequisites, see the IBM ServerProven® website at the following address:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

Physical and electrical specifications

Dimensions and weight:

  • Height: 351 mm (13.7 in.)
  • Width: 482 mm (19.0 in.)
  • Depth: 804 mm (31.6 in.); 903 mm (35.5 in.) with Full-length I/O Book installed
  • Weight:
    • Minimum configuration: 84.5 kg (186.3 lb)
    • Typical configuration: 88.2 kg (194.5 lb)
    • Maximum configuration: 110.0 kg (242.6 lb)

Supported environment:
  • Air temperature:
    • Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 - 3,050 m (10,000 ft).
    • Server off: 5 °C to 45 °C (41 °F to 113 °F); altitude: 0 - 3,050 m (10,000 ft).
    • Shipment: -40 °C to 60 °C (-40 °F to 140 °F)
  • Humidity:
    • Server on: 8% - 85%, maximum dew point 24 °C
    • Server off: 8% - 85%, maximum dew point 27 °C
  • Electrical:
    • Models with 1400 W AC power supplies:
      • 100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 10 A (900 W DC output)
      • 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 8 A (1400 W DC output)
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.16 kVA
        • Maximum configuration: 3.2 kVA
    • Models with 900 W AC power supplies:
      • 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 10.7 A
      • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 5.3 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.16 kVA
        • Maximum configuration: 2.0 kVA
    • Models with 750 W DC power supplies:
      • -40 to -75 (nominal) V DC
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.16 kVA
        • Maximum configuration: 1.7 kVA
  • BTU output:
    • Minimum configuration: 546 Btu/hr (160 watts)
    • Maximum configuration: 10,912 Btu/hr (3,200 watts)
  • Noise level:
    • 6.6 bels (operating)
    • 6.4 bels (idle)

Warranty options

The IBM System x3950 X6 has a three-year onsite warranty with 9x5/next business day terms. IBM offers the warranty service upgrades through IBM ServicePac offerings. IBM ServicePac is a series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

IBM ServicePac offerings are country-specific, that is, each country might have its own service types, service levels, response times, and terms and conditions. Not all covered types of ServicePac offerings might be available in a particular country. For more information about the IBM ServicePac offerings that are available in your country, visit the IBM ServicePac Product Selector at the following address:

https://www-304.ibm.com/sales/gss/download/spst/servicepac

The following table explains the warranty service definitions in more detail.

Table 20. Warranty service definitions

TermDescription
IBM onsite repair (IOR)A service technician comes to the server's location for equipment repair.
24x7x2 hourA service technician is scheduled to arrive at your customer’s location within two hours after remote problem determination is complete. We provide service around the clock, every day, including IBM holidays.
24x7x4 hourA service technician is scheduled to arrive at your customer’s location within four hours after remote problem determination is complete. We provide service around the clock, every day, including IBM holidays.
9x5x4 hourA service technician is scheduled to arrive at your customer’s location within four business hours after remote problem determination is completed. We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding IBM holidays. If after 1:00 p.m. it is determined that onsite service is required, the customer can expect the service technician to arrive the morning of the following business day. For noncritical service requests, a service technician arrives by the end of the following business day.
9x5 next business dayA service technician is scheduled to arrive at your customer’s location on the business day after we receive your call, following remote problem determination. We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding IBM holidays.

In general, the types of IBM ServicePacs are as follows:
  • Warranty and maintenance service upgrades:
    • One, 2, 3, 4, or 5 years of 9x5 or 24x7 service coverage
    • Onsite repair from next business day to 4 or 2 hours
    • One or two years of warranty extension
  • Remote technical support services:
    • One or three years with 24x7 coverage (severity 1) or 9x5/next business day for all severities
    • Installation and start-up support for System x servers
    • Remote technical support for System x servers
    • Software support - Support Line:
      • Microsoft or Linux software
      • VMware
      • IBM Systems Director

Regulatory compliance

The server conforms to the following regulations:

  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 4, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • Australia/New Zealand AS/NZS CISPR 22, Class A
  • IEC 60950-1(CB Certificate and CB Test Report)
  • China CCC (GB4943), GB9254 Class A, GB17625.1
  • Taiwan BSMI CNS13438, Class A; CNS14336-1
  • Korea KN22, Class A; KN24
  • Russia/GOST ME01, IEC-60950-1, GOST R 51318.22, GOST R 51318.24, GOST R 51317.3.2, and GOST R 51317.3.3
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
  • CISPR 22, Class A
  • TUV-GS (EN60950-1 /IEC60950-1, EK1-ITB2000)

External disk storage expansion

The server supports attachment to external storage expansion enclosures, such as the EXP2500 series, by using the ServeRAID M5120 SAS/SATA Controller. The server can also be attached to supported external storage systems, such as the IBM System Storage® DS3500 series, by using a supported HBA (see the earlier "Storage HBA" section). The following table shows the RAID controllers and options for external disk storage expansion.

Table 21. RAID controllers and options for external disk storage expansion

Part numberFeature
code
DescriptionMaximum
supported
x3950 X6
Standard models
where used
81Y4478A1WXServeRAID M5120 SAS/SATA Controller5-
Hardware upgrades for the M5120
81Y4487A1J4ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade1-
81Y4559A1WYServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade1-
Feature on Demand upgrades for the M5120
90Y4318A2MDServeRAID M5100 Series SSD Caching Enabler1*-
90Y4273A2MCServeRAID M5100 Series SSD Performance Key1*-
81Y4546A1X3ServeRAID M5100 Series RAID 6 Upgrade1*-
* These M5120 features upgrades require a cache memory upgrade (81Y4487 or 81Y4559).

The ServeRAID M5120 SAS/SATA Controller has the following specifications:
  • Eight external 6 Gbps SAS/SATA ports
  • Up to 6 Gbps throughput per port
  • Two external x4 mini-SAS connectors (SFF-8088)
  • Supports RAID 0, 1, and 10
  • Supports RAID 5 and 50 with optional M5100 Series RAID 5 upgrades
  • Supports RAID 6 and 60 with the optional M5100 Series RAID 6 upgrade
  • Supports 512 MB or 1 GB flash-backed cache
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS2208 6 Gbps ROC controller
  • Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures

For more information, see the IBM Redbooks Product Guide ServeRAID M5120 SAS/SATA Controller for IBM System x, TIPS0858, found at the following website:
http://www.redbooks.ibm.com/abstracts/tips0858.html?Open

The ServeRAID M5120 SAS/SATA Controller supports connectivity to the IBM System Storage external expansion enclosures that are listed in the following table. Up to nine expansion enclosures can be daisy-chained per one M5120 external port. For better performance, distribute expansion enclosures evenly across both M5120 ports.

Table 22. IBM System Storage external expansion enclosures
Part numberDescriptionMaximum quantity
supported per one M5120
174712XIBM System Storage EXP2512 Express18
174724XIBM System Storage EXP2524 Express9

The external SAS cables that are listed in the following table support connectivity between external expansion enclosures and the ServeRAID M5120 SAS/SATA Controller.

Table 23. External SAS cables for external storage expansion enclosures
Part numberDescriptionMaximum quantity
supported per one enclosure
39R6531IBM 3 m SAS Cable1
39R6529IBM 1 m SAS Cable1

The following table lists the drives that are supported by EXP2512 external expansion enclosures.

Table 24. Drive options for EXP2512 external expansion enclosures
Part numberDescriptionMaximum quantity supported
per one enclosure
3.5" NL SAS HS HDDs
49Y19031TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
49Y19022TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
90Y87203TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
46W09754TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
3.5" SAS HS HDDs
49Y1899300GB 15,000 rpm 6Gb SAS 3.5" HDD12
49Y1900450GB 15,000 rpm 6Gb SAS 3.5" HDD12
49Y1901600GB 15,000 rpm 6Gb SAS 3.5" HDD12

The following table lists the hard disk drives that are supported by EXP2524 external expansion enclosures.

Table 25. Drive options for EXP2524 external expansion enclosures
Part numberDescriptionMaximum quantity supported
per one enclosure
2.5" NL SAS HS HDDs
49Y1898500GB 7,200 rpm 6Gb SAS NL 2.5" HDD24
81Y99521TB 7,200 rpm 6Gb SAS NL 2.5" HDD24
2.5" SAS HS HDDs
49Y1896146GB 15,000 rpm 6Gb SAS 2.5" HDD24
81Y9944300GB 15,000 rpm 6Gb SAS 2.5" HDD24
00W1595600GB 10,000 rpm 6Gb SAS 2.5" HDD24
46W0970900GB 10,000 rpm 6Gb SAS 2.5" HDD24
46W09801.2TB 10,000 rpm 6Gb SAS 2.5" HDD24
2.5" SAS HS SSDs
49Y6072200GB 6Gb SAS 2.5" SSD24
49Y6077400GB 6Gb SAS 2.5" SSD24

External disk storage systems

The following table lists the external storage systems that are supported by the server and can be ordered through the System x sales channel. The server might support other IBM disk systems that are not listed in this table. For more information, see the IBM System Storage Interoperation Center found at http://www.ibm.com/systems/support/storage/ssic.

Table 26. External disk storage systems

Part numberDescription
1746A2D IBM System Storage DS3512 Express Dual Controller Storage System
1746A2S IBM System Storage DS3512 Express Single Controller Storage System
1746A4D IBM System Storage DS3524 Express Dual Controller Storage System
1746A4S IBM System Storage DS3524 Express Single Controller Storage System
181494HIBM System Storage DS3950 Model 94
181498HIBM System Storage DS3950 Model 98
181492HIBM System Storage EXP395 Expansion Unit
1746A2EIBM System Storage EXP3512 Express Storage™ Expansion Unit
1746A4EIBM System Storage EXP3524 Express Storage Expansion Unit

For more information, see the list of IBM Redbooks Product Guides in the System Storage category found at http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=externalstorage.

External backup units

The server supports the external backup attachment options that are listed in the following table.

Table 27. External backup options
Table 27. External backup options (Part 1)

Part numberDescription
External tape expansion enclosures for internal tape drives
87651UX1U Tape Drive Enclosure
8767HHXHalf High Tape Drive Enclosure
87651NX1U Tape Drive Enclosure (with Nema 5-15P LineCord)
8767HNXHalf High Tape Drive Enclosure (with Nema 5-15P LineCord)
Tape enclosure adapters (with cables)
40K2599SAS Enclosure Adapter Kit
Internal backup drives supported by external tape enclosures
43W8478IBM Half High LTO Gen 3 SAS Tape Drive
44E8895IBM Half High LTO Gen 4 SAS Tape Drive
49Y9898IBM Half High LTO Gen 5 Internal SAS Tape Drive
00D8924IBM Half High LTO Ultrium Gen 6 Internal SAS Tape Drive
Table 27. External backup options (Part 2)
Part numberDescription
External backup units*
36251TYIBM RDX External USB 3.0 Dock with 1TB Cartridge
362532YIBM RDX External USB 3.0 Dock with 320GB Cartridge
362550YIBM RDX External USB 3.0 Dock with 500GB Cartridge
3628L3XIBM Half High LTO Gen 3 External SAS Tape Drive (with US power cord)
3628L4XIBM Half High LTO Gen 4 External SAS Tape Drive (with US power cord)
3628L5X IBM Half High LTO Gen 5 External SAS Tape Drive (with US power cord)
3628N3XIBM Half High LTO Gen 3 External SAS Tape Drive (without power cord)
3628N4XIBM Half High LTO Gen 4 External SAS Tape Drive (without power cord)
3628N5XIBM Half High LTO Gen 5 External SAS Tape Drive (without power cord)
3580S3VSystem Storage TS2230 Tape Drive Express Model H3V
3580S4VSystem Storage TS2240 Tape Drive Express Model H4V
3580S5ESystem Storage TS2250 Tape Drive Express Model H5S
3580S5XSystem Storage TS2350 Tape Drive Express Model S53
3572S4RTS2900 Tape Library with LTO4 HH SAS drive & rack mount kit
3572S5RTS2900 Tape Library with LTO5 HH SAS drive & rack mount kit
35732ULTS3100 Tape Library Model L2U Driveless
35734ULTS3200 Tape Library Model L4U Driveless
46X2682†LTO Ultrium 5 Fibre Channel Drive
46X2683†LTO Ultrium 5 SAS Drive Sled
46X2684†LTO Ultrium 5 Half High Fibre Drive Sled
46X2685†LTO Ultrium 5 Half High SAS Drive Sled
46X6912†LTO Ultrium 4 Half High Fibre Channel Drive Sled
46X7117†LTO Ultrium 4 Half High SAS DriveV2 Sled
46X7122†LTO Ultrium 3 Half High SAS DriveV2 Sled
* Note: The external tape drives that are listed can be ordered through the System x sales channel. The server might support other IBM tape drives that are not listed in this table. For more information, see the IBM System Storage Interoperability Center.
† Note: These part numbers are the tape drives options for 35732UL and 35734UL.

For more information, see the list of IBM Redbooks Product Guides in the Backup units category found at the following address:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=tape

Top-of-rack Ethernet switches

The server supports the top-of-rack Ethernet switches from IBM System Networking that are listed in the following table.

Table 28. IBM System Networking - Top-of-rack switches

Part numberDescription
IBM System Networking - 1 Gb top-of-rack switches
0446013IBM System Networking RackSwitch™ G8000R
7309CFCIBM System Networking RackSwitch G8000F
7309CD8IBM System Networking RackSwitch G8000DC
7309G52IBM System Networking RackSwitch G8052R
730952FIBM System Networking RackSwitch G8052F
427348EIBM Ethernet Switch J48E
6630010Juniper Networks EX2200 24 Port
6630011Juniper Networks EX2200 24 Port with PoE
6630012Juniper Networks EX2200 48 Port
6630013Juniper Networks EX2200 48 Port with PoE
IBM System Networking - 10 Gb top-of-rack switches
7309DRXIBM System Networking RackSwitch G8264CS (Rear to Front)
7309DFXIBM System Networking RackSwitch G8264CS (Front to Rear)
7309BD5IBM System Networking RackSwitch G8124DC
7309BR6IBM System Networking RackSwitch G8124ER
7309BF7IBM System Networking RackSwitch G8124EF
7309G64IBM System Networking RackSwitch G8264R
730964FIBM System Networking RackSwitch G8264F
7309CR9IBM System Networking RackSwitch G8264TR
7309CF9IBM System Networking RackSwitch G8264TF
0719410Juniper Networks EX4500 - Front to Back Airflow
0719420Juniper Networks EX4500 - Back to Front Airflow
IBM System Networking - 40 Gb top-of-rack switches
8036BRXIBM System Networking RackSwitch G8332 (Rear to Front)
8036BFXIBM System Networking RackSwitch G8332 (Front to Rear)
8036ARXIBM System Networking RackSwitch G8316R
8036AFXIBM System Networking RackSwitch G8316F

For more information, see the list of IBM Redbooks Product Guides in the Top-of-rack switches category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=tor

Uninterruptible power supply units

The server supports attachments to the uninterruptible power supply (UPS) units that are listed in the following table.

Table 29. Uninterruptible power supply units

Part numberDescription
Rack-mounted UPS
24195KXIBM UPS5000
21303RXIBM UPS 7500XHV
21304RX IBM UPS 10000XHV
53952AXIBM 2200VA LCD 2U Rack UPS (100V/120V)
53952KXIBM 2200VA LCD 2U Rack UPS (230V)
53953AX IBM 3000VA LCD 3U Rack UPS (100 V/120 V)
53953JX IBM 3000VA LCD 3U Rack UPS (200 V/208 V)
53956AX IBM 6000VA LCD 4U Rack UPS (200 V/208 V)
53956KX IBM 6000VA LCD 4U Rack UPS (230 V)
53959KXIBM 11000VA LCD 5U Rack UPS (200V/208V/230V)

For more information, see the list of IBM Redbooks Product Guides in the Power infrastructure category found at the following address:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=power

Power distribution units

The server supports attachments to the power distribution units (PDUs) that are listed in the following table.

Table 30. Power distribution units

Part numberDescription
Switched and Monitored PDUs
46M4002 IBM 1U 9 C19/3 C13 Active Energy Manager DPI PDU
46M4003 IBM 1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU
46M4004 IBM 1U 12 C13 Active Energy Manager DPI PDU
46M4005 IBM 1U 12 C13 Active Energy Manager 60A 3 Phase PDU
46M4167IBM 1U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU
46M4116IBM 0U 24 C13 Switched and Monitored 30A PDU
46M4119IBM 0U 24 C13 Switched and Monitored 32A PDU
46M4134IBM 0U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU
46M4137IBM 0U 12 C19/12 C13 Switched and Monitored 32A 3 Phase PDU
Enterprise PDUs
71762MX IBM Ultra Density Enterprise PDU C19 PDU+ (WW)
71762NX IBM Ultra Density Enterprise PDU C19 PDU (WW)
71763MU IBM Ultra Density Enterprise PDU C19 3 Phase 60A PDU+ (NA)
71763NU IBM Ultra Density Enterprise PDU C19 3 Phase 60A PDU (NA)
39M2816IBM DPI C13 Enterprise PDU without power cord
39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed power cord
39Y8941 DPI Single Phase C13 Enterprise PDU without power cord
39Y8948 DPI Single Phase C19 Enterprise PDU without power cord
Front-end PDUs
39Y8934DPI 32 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector
39Y8935DPI 63 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector
39Y893830 amp/125 V Front-end PDU with NEMA L5-30P connector
39Y893930 amp/250 V Front-end PDU with NEMA L6-30P connector
39Y894060 amp/250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector
Universal PDUs
39Y8951DPI Universal Rack PDU with US LV and HV power cords
39Y8952DPI Universal Rack PDU with CEE7-VII Europe LC
39Y8953DPI Universal Rack PDU with Denmark LC
39Y8954DPI Universal Rack PDU with Israel LC
39Y8955 DPI Universal Rack PDU with Italy LC
39Y8956DPI Universal Rack PDU with South Africa LC
39Y8957DPI Universal Rack PDU with UK LC
39Y8958DPI Universal Rack PDU with AS/NZ LC
39Y8959DPI Universal Rack PDU with China LC
39Y8962DPI Universal Rack PDU (Argentina)
39Y8960DPI Universal Rack PDU (Brazil)
39Y8961DPI Universal Rack PDU (India)
0U Basic PDUs
46M4122IBM 0U 24 C13 16A 3 Phase PDU
46M4125 IBM 0U 24 C13 30A 3 Phase PDU
46M4128 IBM 0U 24 C13 30A PDU
46M4131IBM 0U 24 C13 32A PDU
46M4140 IBM 0U 12 C19/12 C13 60A 3 Phase PDU
46M4143IBM 0U 12 C19/12 C13 32A 3 Phase PDU

For more information, see the list of IBM Redbooks Product Guides in the Power infrastructure category found at the following address:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=power

Rack cabinets

The server supports the rack cabinets that are listed in the following table.

Table 31. Rack cabinets

Part numberDescriptionSupported
by x3950 X6
Maximum
supported
x3950 X6
2018-86XIBM 11U Office Enablement KitNoNot applicable
9307-2PXIBM 25U Static S2 Standard RackNoNot applicable
9307-2RXIBM 25U Standard Rack NoNot applicable
9307-4RXIBM 42U Standard Rack NoNot applicable
9307-4XXIBM 42U Standard Rack ExtensionNoNot applicable
9308-4EXIBM 42U Enterprise Expansion RackYes*5
9308-4PXIBM 42U Enterprise RackYes*5
9360-4PXIBM 42U 1200mm Deep Dynamic RackYes5
9360-4EXIBM 42U 1200mm Deep Dynamic Expansion RackYes5
9361-4PXIBM 42U 1200mm Deep Static RackYes5
9361-4EXIBM 42U 1200mm Deep Static Expansion RackYes5
9362-4PXIBM 47U 1200mm Deep Static RackYes5
9362-4EXIBM 47U 1200mm Deep Static Expansion RackYes5
9363-4CXIBM PureFlex System 42U RackYes5
9363-4DXIBM PureFlex System 42U Expansion RackYes5
9363-4PXIBM 42U 1100mm Dynamic RackYes5
9363-4EXIBM 42U 1100mm Dynamic Expansion RackYes5
1410-2RXIntelligent Cluster 25U Rack FamilyNoNot applicable
1410-4RXIntelligent Cluster 42U Rack FamilyYes*5
1410-PRAIntelligent Cluster 42U 1200mm Deep Rack FamilyYes5
1410-PRBIntelligent Cluster 42U 1100mm Enterprise V2 Rack FamilyYes5
7200-4PXSmart Analytics 42U Rack FamilyYes*5
* No support for Full-length I/O Books

For more information, see the list of IBM Redbooks Product Guides in the Rack cabinets and options category found at the following address:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=rack

Rack options

The server supports the rack console switches and monitor kits that are listed in the following table.

Table 32. Rack options

Part numberFeature codeDescription
Monitor kits and keyboard trays
17238BXA3EKIBM 1U 18.5" Standard Console
17238EXA3ELIBM 1U 18.5" Enhanced Media Console
172317X00511U 17in Flat Panel Console Kit
172319X00521U 19in Flat Panel Console Kit
Console switches
3858D3X3858HC1 fc A4X1Avocent Universal Management Gateway 6000 for IBM
1754D2X6695IBM Global 4x2x32 Console Manager (GCM32)
1754D1X6694IBM Global 2x2x16 Console Manager (GCM16)
1754A2X0726IBM Local 2x16 Console Manager (LCM16)
1754A1X0725IBM Local 1x8 Console Manager (LCM8)
Console cables
43V61473757IBM Single Cable USB Conversion Option (UCO)
39M28953756IBM USB Conversion Option (4 Pack UCO)
46M53835341IBM Virtual Media Conversion Option Gen2 (VCO2)
46M53825340IBM Serial Conversion Option (SCO)

For more information, see the list of IBM Redbooks Product Guides in the Rack cabinets and options category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=rack

IBM Global Financing

IBM Global Financing can help you obtain the IT solution that you need while preserving funding for other strategic investments and optimizing cash flow. Our Fair Market Value (FMV) lease helps ensure that you have the latest IBM technology and with our mid-lease upgrade capability, you can increase the capacity of the system with little to no change in monthly payments. At the end of the lease, take advantage of our flexible end-of-lease options to fit your changing business needs. IBM Global Financing has the breadth and depth of offerings, longevity, proven success, and global reach to help you develop a robust financing and asset management strategy that provides you the opportunity to leverage new technologies and turn your ambitious vision into a tangible solution.

Here are some other reasons why working with us makes solid financial sense:

  • Expand your purchasing power: Affordable monthly payments allow you to change the technology acquisition discussion from “what can I afford right now” to “what solution is really right for my business.” IBM Global Financing allows you to expand your purchase power to get you the right solution.
  • Accelerate your project’s cash flow break-even point: Acquire your IBM technology today and begin to realize its benefits now. An FMV lease can help you get the solution that you need now, with low monthly payments that better align upfront costs with the anticipated return on investment from the technology.
  • Easy to acquire with affordable rates: We offer one-stop shopping for a total IT solution, so you can acquire IBM hardware, software, services, and the financing you need from one IT provider.

Plus, we provide simple, easy-to-understand contracts and quick approvals. As the world’s largest IT financing provider, with an asset base of US$35.8 billion and over 125,000 customers, IBM Global Financing offers highly competitive rates that promote low total cost of ownership and low monthly payments.

IBM Global Financing operates in more than 50 countries. Go to http://ibm.com/financing for financing options in your country and to contact a local financing specialist.

IBM Global Financing offerings are provided through IBM Credit LLC in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients. Rates and availability subject to client’s credit rating, financing terms, offering type, equipment, and product type and options, and may vary by country. Non-hardware items must be one-time, non-recurring charges and are financed by means of loans. Other restrictions may apply. Rates and offerings are subject to change, extension or withdrawal without notice and may not be available in all countries. Contact your local IBM Global Financing representative for additional detail.

Related publications and links

For more information, see these resources:


Special Notices

This material has not been submitted to any formal IBM test and is published AS IS. It has not been the subject of rigorous review. IBM assumes no responsibility for its accuracy or completeness. The use of this information or the implementation of any of these techniques is a client responsibility and depends upon the client's ability to evaluate and integrate them into the client's operational environment.

Profile

Publish Date
18 February 2014

Last Update
22 April 2014


Rating: Not yet rated


Author(s)

IBM Form Number
TIPS1132