The System x3950 X6 server is an eight-socket 8U rack-mounted server that represents the sixth generation of the Enterprise X-Architecture. It delivers fast application performance, is based on an agile system design, and is a resilient platform that is needed for mission-critical databases, enterprise applications, and virtualized environments.

The x3950 X6 packs numerous fault-tolerant and high-availability features into a high-density, 8U rack-optimized lid-less package that helps reduce the space that is needed to support massive network computing operations and simplify servicing. The x3950 X6 supports up to eight Intel Xeon E7-8800 v2 high-performance processors and up to 12 TB of memory.

Suggested use: Mission-critical scalable databases, business analytics, virtualization, enterprise applications, and cloud applications.

Note: This Product Guide describes the models of the System x3950 X6, machine type 3837. For machine type 6241, see the Lenovo Press Product Guide Lenovo System x3950 X6 (6241).

Changes in the March 18 update:
* Added support for the ThinkServer SA120 Storage Array
* Added the Lenovo Financial Services section


Video walk-through

Contents



Introduction

The System x3950 X6 server is an eight-socket 8U rack-mounted server that represents the sixth generation of the Enterprise X-Architecture. It delivers fast application performance, is based on an agile system design, and is a resilient platform that is needed for mission-critical databases, enterprise applications, and virtualized environments.

The x3950 X6 packs numerous fault-tolerant and high-availability features into a high-density, 8U rack-optimized lid-less package that helps reduce the space that is needed to support massive network computing operations and simplify servicing. The x3950 X6 supports up to eight Intel Xeon E7-8800 v2 high-performance processors and up to 12 TB of memory.

Suggested use: mission-critical scalable databases, business analytics, virtualization, enterprise applications, and cloud applications.

The System x3950 X6
Figure 1. The System x3950 X6

Did you know?

The x3950 X6 server employs a lid-less design where all serviceable components are front- and rear-accessible. In addition, each major subsystem is implemented as modular "book" design, such as the Compute Books and I/O Books. This configuration means that components are easy to upgrade and service, which translates to greater uptime of applications to your users. The x3950 X6 offers enterprise scalability and advanced RAS features to support the most demanding mission-critical applications that require 24x7 operations.

Key features

The increasing demand for cloud-computing and analytics workloads by enterprises to meet social, mobile, and Big Data requirements drives innovation to find new ways to build informational systems. Clients are looking for cost-optimized fit-for-purpose IT solutions that manage large amounts of data, easily scale performance, and provide enterprise class reliability.

Built on decades of innovation, Lenovo introduces its sixth generation of Enterprise X-Architecture technology, X6 servers. Lenovo X6 servers are fast, agile, and resilient:

  • Fast application performance means immediate access to actionable information.
  • Agile system design helps to reduce acquisition costs and provide the ability to upgrade processor and memory technology at each refresh within the same chassis.
  • Resilient platforms maximize application uptime and promote easy integration in virtual environments.

X6 servers continue to lead the way as the shift toward mission-critical scalable databases, business analytics, virtualization, enterprise applications, and cloud-computing applications accelerates.

Fast application performance

The server offer numerous features to boost performance:
  • With eXFlash memory-channel storage, the server delivers up to 12.8 TB of ultra-low latency flash memory by using WriteNow technology, which is ideal for high-performance applications.
  • Supports four, six, or eight E7-8800 v2 processors with 120 cores and 240 threads to maximize the concurrent running of multi-threaded applications.
  • Supports memory speeds up to 1600 MHz.
  • Supports up to 12 TB of memory in 192 DIMM sockets, with 24 DIMMs per processor.
  • Supports memory-channel storage (eXFlash DIMMs), where solid-state storage devices are installed in memory DIMM sockets. These devices are directly connected to the processors and provide the lowest latency values in the industry.
  • Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
  • Intel Hyper-Threading Technology boosts performance for multi-threaded applications by enabling simultaneous multi-threading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Intel Advanced Vector Extensions (AVX) improve floating-point performance for compute-intensive technical and scientific applications.
  • Supports a 12 Gbps SAS RAID portfolio.
  • The usage of solid-state drives (SSDs) instead of, or along with, traditional spinning drives (HDDs) can improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
  • PCI Express 3.0 I/O adapter slots that improve the theoretical maximum bandwidth by almost 100% (8 GTps per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GTps per link using 8b/10b encoding).
  • With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E7-4800/8800 v2 product families. This integration helps reduce I/O latency and increase overall system performance.
  • Support for up to four graphics processing units (GPUs) and co-processors to maximize computing power.
  • Energy-efficient electronic components help lower operational costs, including highly efficient 900 W AC and 1400 W AC power supplies with 80 PLUS Platinum certification.


Agile system design

The server provides many scalability and flexibility features:
  • Innovative module "book" design for each of the three subsystems: Compute Books, Storage Book, and I/O Books. Front and rear access means that you can easily scale the system by adding components without removing the entire server from the rack.
  • The modular book design also allows clients to create the configuration that fits their application and environment needs, which reduces acquisition costs while giving them the flexibility to grow and modify their configuration later.
  • The book design also means that subsystem upgrades are simpler, quicker to perform, and have a lower impact on the rest of the server.
  • Using 64 GB LRDIMMs, the server supports up to 12 TB of memory.
  • Up to 32 eXFlash DIMMs are supported for a total of 12.8 TB of low-latency and high-performance storage.
  • Up to 32x 1.8-inch eXFlash SSD bays, or up to 16x 2.5-inch bays, provide a flexible and scalable all-in-one platform to meet your increasing demands.
  • Offers up to 22 PCIe slots plus two dedicated Mezzanine LOM (ML2) adapter slots. Most slots are PCIe 3.0 to maximize I/O scalability.
  • PCIe slots are implemented in I/O Books to maximize modularity. Choose from Half-length I/O Books or Full-length I/O Books, depending on the adapters that you need to deploy.
  • Most components are common between the four-socket x3850 X6 and eight-socket x3950 X6, making for a simple upgrade path with minimal parts on the floor.


Resilient platform

The server provides many features to simplify serviceability and increase system uptime:
  • Upward Integration Modules for standard hypervisors enable the creation and management of policies to maintain high availability of virtual machines and concurrent updating of the system firmware, with no impact on application performance or availability.
  • Advanced Processor Recovery allows the system to automatically switch access and control of networking, management, and storage in the event of a processor 1 failure, providing higher availability and productivity.
  • Advanced Page Retire proactively protects applications from corrupted pages in memory, which is crucial for scaling memory to terabytes.
  • Redundant bit steering, memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
  • Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, which is protected from all other software running on a system.
  • Redundant Intel Platform Controller Hub (PCH) connections to the processors allow the platform to maintain access to networking, storage, and server management during a processor failure.
  • Hot-swap drives support RAID redundancy for data protection and greater system uptime.
  • Hot-swap I/O Books enabling you to install or replace adapters while the server is still running.
  • Tool-less lid-less design provides front and rear access for easy upgrades and serviceability. There is no need to pull the server out of the rack to access internal components.
  • Hot-swap power supplies and hot-swap dual-motor redundant fans provide availability for mission-critical applications.
  • A new LCD diagnostics panel that is combined with individual light path diagnostic LEDs quickly lead the technician to failed (or failing) components, which simplifies servicing, speeds up problem resolution, and helps improve system availability.
  • Predictive Failure Analysis (PFA) detects when system components (processors, memory, HDDs, SSDs, fans, and power supplies) operate outside of standard thresholds and generates proactive alerts in advance of a possible failure, therefore increasing uptime.
  • Built-in Integrated Management Module Version II (IMM2) continuously monitors system parameters, triggers alerts, and performs recovering actions in case of failures to minimize downtime.
  • Includes two special Mezzanine LOM (ML2) adapter slots with support for adapters with either two 10 Gb ports or 4 Gb ports. Supports direct connectivity to the IMM2 service processor for out-of-band systems management.
  • Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
  • Two integrated Trusted Platform Modules (TPMs) 1.2 support enables advanced cryptographic functionality, such as digital signatures and remote attestation.
  • Industry-standard Advanced Encryption Standard (AES) NI support for faster and stronger encryption.
  • IBM Systems Director® provides proactive systems management. It offers comprehensive systems management tools that help increase uptime, reduce costs, and improve productivity through advanced server management capabilities.
  • Solid-state drives (SSDs) offer better reliability than traditional mechanical HDDs for greater uptime.
  • Built-in diagnostic tests, using Dynamic Systems Analysis (DSA) Preboot, speed up troubleshooting tasks to reduce service time.
  • Three-year customer-replaceable unit and onsite limited warranty, 9x5 next business day. Optional service upgrades are available.

Locations of key components and connectors

The following figure shows the front of the x3950 X6 server.

Front view of the System x3950 X6
Figure 2. Front view of the System x3950 X6

The following figure shows the rear of the x3950 X6 server.

Rear view of the System x3950 X6
Figure 3. Rear view of the System x3950 X6

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications

ComponentsSpecification
Machine type3837
FirmwareIBM-signed firmware
Form factor8U rack
ProcessorUp to eight Intel Xeon E7-8800 v2 processors, each in a Compute Book. Each processor has either 15 cores (up to 2.8 GHz), 12 cores (up to 2.6 GHz), 10 cores (up to 2.2 GHz), eight cores (up to 2.0 GHz), or six cores (up to 3.4 GHz). There are three QPI links up to 8.0 GTps each. Up to 1600 MHz memory speed. Up to 37.5 MB L3 cache. Intel C602J chipset.
MemoryUp to 192 DIMM sockets (24 DIMMs per processor, installed in the Compute Book). RDIMMs and LRDIMMs (Load Reduced DIMMs) are supported, but memory types cannot be intermixed. Memory speed up to 1600 MHz.
Memory maximumsWith RDIMMs: Up to 3 TB with 192x 16 GB RDIMMs and eight processors.
With LRDIMMs: Up to 12 TB with 192x 64 GB LRDIMMs and eight processors.
Memory protectionECC, Chipkill, RBS, memory mirroring, and memory rank sparing.
Memory- channel storageOptional on all models. eXFlash DIMMs are installed in memory DIMM slots, but are seen by the OS as storage devices. Memory channels with eXFlash DIMMs must also have at least one RDIMM. Cannot be mixed with LRDIMMs. A maximum of 32 eXFlash DIMMs can be installed. Maximum 12.8 TB with 32x 400GB eXFlash DIMMs.
Disk drive baysUp to thirty-two 1.8-inch eXFlash SSD bays, or up to 16x eight 2.5-inch hot-swap SAS/SATA bays.
Maximum internal storage Up to 28.8 TB with 1.8 TB 2.5-inch SAS HDDs, up to 25.6 TB with 1.6 TB 2.5-inch SAS SSDs, or up to 25.6 TB with 800 GB 1.8-inch SATA SSDs.
RAID support12 Gb SAS/SATA RAID 0, 1, or 10 with ServeRAID M5210; optional upgrades to RAID 5 or 50 are available (zero-cache; 1 GB non-backed cache; 1 GB or 2 GB flash-backed cache). Upgrades to RAID 6 or 60 available for M5210 with 1 GB or 2 GB upgrades.
Optical and tape baysNone.
Network interfacesMezzanine LOM (ML2) slot for dual-port 10 GbE cards with SFP+ or RJ-45 connectors or quad-port GbE cards with RJ-45 connectors. See Table 2. Dedicated 1 GbE port for systems management.
PCI Expansion slots Up to 22 PCIe slots plus two dedicated Mezzanine LOM slots. The slots are as follows:
  • Four PCIe 3.0 x8 slots for internal RAID controllers (in two Storage Books)
  • Four PCIe 3.0 x16 slots (x16-wired), half length, full height (in two Primary I/O Books)
  • Two PCIe 3.0 x16 (x8-wired), half length, full height (in two Primary I/O Books)
  • Two ML2 slots for network adapter (PCIe 3.0 x8) (in two Primary I/O Books)
  • Four optional I/O Books, each with three slots, all full height (using two requires 6 processors; using all four requires 8 processors). Optional books are hot-swap capable.
Optional I/O Books can be either of the following options:
  • Half-length I/O Book: Two PCIe 3.0 x8 slots, one PCIe 3.0 x16 slot.
  • Full-length I/O Book: Two PCIe 3.0 x16, one PCIe 2.0 x4 slot; two aux power connectors: 150 W and 75 W. Supports one double-wide GPU up to 300 W.
PortsFront: Four USB 3.0, two USB 2.0, and one DB-15 video ports. Rear: Eight USB 2.0, one DB-15 video, one DB-9 serial, and one 1 GbE RJ-45 IMM2 systems management. Internal: two USB 2.0 port for embedded hypervisor. The second video IMM2 and internal USB hypervisor ports are used only when the server is partitioned into two four-socket servers.
CoolingCalibrated Vectored Cooling™. Up to 20 redundant hot-swap fan packs and 10 fan zones with N+1 fan redundancy. Each fan pack includes two counter-rotated dual-motor fans.
Power supplyUp to eight redundant hot-swap 900 W AC or 1400 W AC power supplies (all 80 PLUS Platinum certified). -48 V 750 W DC power supplies are available through CTO.
Hot-swap partsDrives, power supplies, fans, and optional I/O Books.
VideoMatrox G200eR2 with 16 MB memory that is integrated into the IMM2. Maximum resolution is 1600 x 1200 at 75 Hz with 16 M colors.
Security featuresPower-on password, admin password, and four Trusted Platform Modules (TPMs).
Systems management UEFI, Integrated Management Module II (IMM2) with remote presence feature, Predictive Failure Analysis, Light Path Diagnostics, Automatic Server Restart, IBM Systems Director and Active Energy Manager™, and ServerGuide.
Operating systems supported Microsoft Windows Server 2012 R2, 2012, and 2008 R2, Red Hat Enterprise Linux 6 and 7, SUSE Linux Enterprise Server 11 and 12, and VMware vSphere ESXi 5.1 and 5.5.
Limited warranty Three-year customer-replaceable unit (CRU) and onsite limited warranty with 9x5 next business day (NBD).
Service and supportOptional service upgrades are available through ServicePac® offerings: 4-hour or 2-hour response time, 8-hour fix time, 1-year or 2-year warranty extension, and remote technical support for Lenovo hardware and some Lenovo / OEM applications.
DimensionsHeight: 351 mm (13.7 in.), width: 482 mm (19.0 in.), depth: 804 mm (31.6 in), depth with cable management brackets installed: 836 mm (32.9 in), depth with Full-length I/O Book installed: 921 mm (36.2 in)
WeightMinimum configuration: 84.5 kg (186.3 lb), typical: 88.2 kg (194.5 lb), maximum: 110.0 kg (242.6 lb)

The server is shipped with the following items:
  • Rail kit
  • Cable management brackets
  • 2.8 m (9.18 ft) C13-C14 power cord (one for each power supply)
  • Statement of Limited Warranty
  • Important Notices
  • Rack Installation Instructions
  • Documentation CD that contains the Installation and Service Guide
  • IBM Systems Director Flyer

Standard models

The following table lists the standard models.

Table 2. Standard models

Model†Intel Xeon Processor**
(in a Compute Book)
MemoryeXFlash
DIMMs
RAIDDrive bays
Drives
Ethernet‡
(ML2 slot)
I/O
slots§
Power
supplies
3837-BAx4x Xeon E7-8850 v2
12C 2.3GHz 24MB 105W
8x 8GB
1600MHz
Optional1x M52104x 2.5" HS / 16
Open bay
4x 1 GbE12 / 244x 900W
HS / 8
3837-CAx4x Xeon E7-8870 v2 15C
2.3GHz 30MB 130W
8x 8GB
1600MHz
Optional1x M52104x 2.5" HS / 16
Open bay
4x 1 GbE12 / 244x 900W
HS / 8
3837-CCx4x Xeon E7-8890 v2 15C
2.8GHz 37.5MB 155W
8x 8GB
1600MHz
Optional1x M52104x 2.5" HS / 16
Open bay
4x 1 GbE12 / 244x 900W
HS / 8
† x in the Machine Type Model (MTM) represents a country-specific letter (for example, the EMEA MTM is 3837-BAG, and the US MTM is 3837-BAU). Ask a Lenovo representative for specifics.
** Processor detail: Processor quantity and model, cores, core speed, L3 cache, and TDP.
‡ All models include one Intel I350-T4 ML2 Quad Port GbE Adapter adapter (I350-AM4 based).
§ Models with 12 slots have two Primary I/O Books (each with four slots) and two Storage Books (each with two slots) standard.

For more information about the standard features of the server, see the "Specifications" section.

SAP HANA Workload Optimized Solution models

The System x3950 X6 Workload Optimized Solutions for SAP HANA provide optimal solutions for SAP NetWeaver Business Warehouse, data mart, and SAP Business Suite, Powered by SAP HANA applications. Preconfigured workload optimized server models for SAP HANA applications are configured with up to 2 TB of memory and are upgradeable to support larger single node and scale-out cluster implementations. These models include IBM General Parallel File System (GPFS) Single Server for x86 Integrated Offerings with 3-year software subscription and support.

The following table lists the Workload Optimized Solution models for SAP HANA.

Table 3. Workload Optimized Solution models for SAP HANA

ModelIntel Xeon Processor
(in a Compute Book)
MemoryRAIDDrive bays
Drives
EthernetI/O
slots
Power
supplies
3837-
HBx
4x E7-8880 v2 15C
2.5GHz 37.5MB
1600 MHz 130W
512 GB
32x 16 GB
RDIMM
1x M5210
+ upgrades*
8x 2.5” HS
6x 1.2 TB SAS HDD
2x 400 GB S3700 SSD
2x 4x1GbE ML2
2x Mellanox 10Gb*
12 std
24 max
8x 1400W
HS / 8
3837-
HCx
4x E7-8880 v2 15C
2.5GHz 37.5MB
1600 MHz 130W
1024 GB
32x 32 GB
LRDIMM
2x M5210
+ upgrades*
16x 2.5” HS
12x 1.2 TB SAS HDD
4x 400 GB S3700 SSD
2x 4x1GbE ML2
2x Mellanox 10Gb*
12 std
24 max
8x 1400W
HS / 8
3837-
HDx
8x E7-8880 v2 15C
2.5GHz 37.5MB
1600 MHz 130W
2048 GB
64x 32 GB
LRDIMM
2x M5210
+ upgrades*
16x 2.5” HS
12x 1.2 TB SAS HDD
4x 400 GB S3700 SSD
2x 4x1GbE ML2
2x Mellanox 10Gb*
18 std
24 max
8x 1400W
HS / 8
* See the list of specific components below

Each of these HANA models include the following components
  • One (model HBx) or two (HCx, HDx) ServeRAID M5210 controller (46C9110) with 2GB cache upgrade with flash backup (47C8664) plus Performance Accelerator (47C8710) and SSD Caching Enabler (47C8712)
  • Six (HBx) or 12 (HCx, HDx) 1.2TB 10K 6Gbps SAS 2.5" G3HS HDD (00AJ146)
  • Two (HBx) or four (HCx, HDx) S3700 400GB SATA 2.5" MLC G3HS Enterprise SSD for System x (00AJ161)
  • Two Intel I350-T4 ML2 Quad Port GbE Adapter for System x (00D1998)
  • Two Mellanox ConnectX-3 40GbE / FDR IB VPI Adapters (00D9550)
  • Four SFP+ SR Transceiver (46C3447)
  • Four Mellanox QSA Adapter (QSFP to SFP+) (90Y3842)
  • Model HDx only: Two X6 Half-length I/O Books (44X4049)
  • Lenovo solution for SAP HANA media
  • License for IBM General Parallel File System (GPFS) Single Server for x86 Integrated Offerings with 3-year software subscription and support

Note: The operating system software is not included with the SAP HANA models. Operating system selection must be a separate line item included in order: SLES for SAP with standard or priority support. The SAP HANA Software is included, but the license is sold separately by SAP or an SAP business partner. VMware Enterprise Plus license sold separately.

For more information about the standard features of the server, see the "Specifications" section.

Processor options

The x3950 X6 supports up to eight Intel Xeon E7-8800 v2 processors. Processors are installed in Compute Books, one processor in each Compute Book. The following figure shows the components of the Compute Book:

  • One processor
  • A total of 24 DIMM slots, 12 on each side of the book
  • Two hot-swap dual-motor fans that are mounted on the front of the book

The x3950 X6 supports four, six, or eight Compute Books. Other combinations are not supported.

Each Compute Book is installed in the front of the server, as shown in the following figure.

Compute Book
Figure 4. Compute Book

The following table shows the processor options. Each option includes the processor installed in a Compute Book.

Note: Compute Books with E7-4800 v2 processors are supported only in a four-socket x3850 X6 server and cannot be used in an x3950 X6 server.

The table also shows the maximum memory bus speed each processor supports plus which server models have each processor standard. If there is no corresponding where-used model for a particular processor, this processor is only available through CTO.

Table 4. Processor options
Part numberFeature
code
Description
(processor installed in a Compute Book)
Memory bus
speed (RAS /
Performance)†
Supported
quantities
x3950 X6
x3950 X6
models
where used
Intel Xeon E7-8800 v2 processor family (also supported in x3850 X6)
44X4001A4BBX6 Compute Book Intel Xeon E7-8850 v2 12C 2.3GHz 105W1600 / 1066 MHz4, 6, 8BAx
44X4031A4BHX6 Compute Book Intel Xeon E7-8857 v2 12C 3.0GHz 130W1600 / 1333 MHz4, 6, 8-
44X4011A4BDX6 Compute Book Intel Xeon E7-8870 v2 15C 2.3GHz 130W1600 / 1333 MHz4, 6, 8CAx
44X4016A4BEX6 Compute Book Intel Xeon E7-8880 v2 15C 2.5GHz 130W1600 / 1333 MHz4, 6, 8-
44X4036A4BJX6 Compute Book Intel Xeon E7-8880L v2 15C 2.2GHz 105W1600 / 1333 MHz4, 6, 8-
44X4021A4BFX6 Compute Book Intel Xeon E7-8890 v2 15C 2.8GHz 155W1600 / 1333 MHz4, 6, 8CCx
44X4026A4BGX6 Compute Book Intel Xeon E7-8891 v2 10C 3.2GHz 155W1600 / 1333 MHz4, 6, 8-
44X4006A4BCX6 Compute Book Intel Xeon E7-8893 v2 6C 3.4GHz 155W1600 / 1333 MHz4, 6, 8-
† The processors support two memory modes, RAS mode (also known as lockstep mode) and Performance mode (also known as independent mode). In Performance mode, the SMI2 link operates at twice the memory bus speed shown.

Memory options

Lenovo DDR3 memory is compatibility tested and tuned for optimal System x performance and throughput. Lenovo memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime. From a service and support standpoint, Lenovo memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.

The x3950 X6 supports DDR3 memory operating at speeds up to 1600 MHz. The server supports up to 192 DIMMs when all eight processors are installed, 24 DIMMs per processor. Each processor has four memory channels that are implemented using Scalable Memory Interface generation 2 (SMI2) chips, and the server implements three DIMMs per channel. The processor and the corresponding memory DIMM slots are on the Compute Book.

The following table lists the memory options that are available for x3950 X6.

Table 5. Memory options

Part numberFeature codeDescriptionMaximum
supported
x3950 X6
Standard models
where used
RDIMMs
00D5024A3QE4GB (1x4GB, 1Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM192 (24 per CPU)-
00D5036A3QH8GB (1x8GB, 1Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM192 (24 per CPU)BAx, CAx, CCx
46W0672A3QM16GB (1x16GB, 2Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM192 (24 per CPU)-
LRDIMMs
46W0676A3SR32GB (1x32GB, 4Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP LRDIMM192 (24 per CPU)-
46W0741A45164GB (1x64GB, 8Rx4, 1.35V) PC3-10600 DDR3 1333MHz LP LRDIMM192 (24 per CPU)-

The following rules apply when selecting the memory configuration:
  • The server supports RDIMMs and LRDIMMs.
  • Mixing different types of memory (RDIMMs and LRDIMMs) is not supported.
  • The maximum number of ranks per one DDR3 channel is six with RDIMMs or 24 with LRDIMMs.
  • In RAS (lockstep) mode, DIMMs must be installed in a pair.
  • The maximum quantity of DIMMs that can be installed in the server depends on the number of processors, DIMM type, rank, and operating voltage, as shown in the "Max. qty supported" row in the following table.
  • All DIMMs in the server operate at the same speed, which is determined as the lowest value of one of the following options:
    • Memory speed that is supported by the specific processor.
    • Lowest of maximum operating speeds for selected memory configuration that depends on rated speed, operating voltage, and quantity of DIMMs per channel, as shown under "Maximum operating speed" section in the following table.
  • The server also supports eXFlash DIMMs, which are also installed in the DIMM slots. The "eXFlash memory-channel storage" section describes these eXFlash DIMMs and the configuration rules.

The following table shows the characteristics of the supported DIMMs. Tables cells that are highlighted with a gray background indicate that the server supports higher memory frequencies or larger memory capacity (or both) than the Intel processor specification defines.

Memory speed: In performance mode, memory channels operate independently, and the SMI2 link operates at twice the DDR3 speed. In RAS mode, two channels operate synchronously, and the SMI2 link operates at the DDR3 speed.

Table 6. Maximum memory speeds
DIMM
specification
RDIMM
LRDIMM
Rank
Single rank
Dual rank
Quad rank
8-rank
Part numbers
00D5024 (4GB)
00D5036 (8GB)
46W0672 (16GB)
46W0676 (32GB)
46W0741 (64GB)
Rated speed
1600 MHz
1600 MHz
1600 MHz
1333 MHz
Rated voltage
1.35 V
1.35 V
1.35 V
1.35 V
Operating voltage
1.35 V
1.5 V
1.35 V
1.5 V
1.35 V
1.5 V
1.35 V
1.5 V
Max qty supported*
192
192
192
192
192
192
192
192
Max DIMM capacity
8 GB
8 GB
16 GB
16 GB
32 GB
32 GB
64 GB
64 GB
Max memory capacity
1.5 TB
1.5 TB
3.0 TB
3.0 TB
6 TB
6 TB
12 TB
12 TB
Maximum operating speed - Performance mode (2:1 mode - SMI2 link operates at twice the DDR3 speed shown)
1 DIMM per channel
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
2 DIMMs per channel
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
3 DIMMs per channel
1066 MHz
1333 MHz
1066 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
Maximum operating speed - RAS mode (1:1 mode - SMI2 link operates at the DDR3 speed shown)
1 DIMM per channel
1333 MHz
1600 MHz
1333 MHz
1600 MHz
1333 MHz
1600 MHz
1333 MHz
1333 MHz
2 DIMMs per channel
1333 MHz
1600 MHz
1333 MHz
1600 MHz
1333 MHz
1600 MHz
1333 MHz
1333 MHz
3 DIMMs per channel
1066 MHz
1333 MHz
1066 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1333 MHz
* Maximum quantity supported is shown for all processors installed.

The following memory protection technologies are supported:
  • ECC
  • Chipkill (for x4-based memory DIMMs)
  • Redundant bit steering (Double Device Data Correction)
  • Memory mirroring
  • Memory rank sparing

Chipkill and Redundant Bit Steering are supported in RAS mode. Chipkill is supported in Performance mode.

If memory mirroring is used, DIMMs must be installed in pairs for Performance mode (minimum of one pair per each processor) and quads for RAS mode. DIMMs in the pair/quad must be identical in type and size.

If memory rank sparing is used, then a minimum of two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need being identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs that are installed.

eXFlash memory-channel storage

eXFlash memory-channel storage are storage offerings in the physical form of memory DIMMs. These eXFlash DIMMs are installed in memory DIMM sockets but appear to the operating system and applications as block storage devices. This new and innovative technology brings storage electrically closer to the processor subsystem, therefore improving performance considerably.

Note: Both the x3850 X6 and the x3950 X6 support at most 32 eXFlash DIMMs.

The following table shows the supported eXFlash DIMMs.

Table 7. Internal storage expansion options

Part numberFeature
code
Name and descriptionMaximum
supported
x3950 X6
00FE000A4GXeXFlash 200GB DDR3 Storage DIMM32
00FE005A4GYeXFlash 400GB DDR3 Storage DIMM32

The following figure shows one eXFlash DIMM installed with RDIMMs in the Compute Book.

IBM eXFlash DIMM installed in the Compute Book
Figure 5. eXFlash DIMM installed in the Compute Book

The following rules apply when building a server configuration with eXFlash DIMMs:
  • The 200 GB and 400 GB eXFlash DIMMs cannot be mixed.
  • Performance memory mode must be selected. RAS (lockstep) memory mode is not supported.
  • Only RDIMMs are supported by eXFlash DIMMs; LRDIMMs are not supported
  • eXFlash DIMMs can only installed on the Compute Books in the lower half of the server (processors 1-4)
  • The maximum quantities of eXFlash DIMMs are as follows:
    • Four processors: 16 eXFlash DIMMs
    • Six processors: 24 eXFlash DIMMs
    • Eight processors: 32 eXFlash DIMMs
For more information, visit the eXFlash DIMM support page:
http://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-FLASHDM

Internal storage

The server supports 1.8-inch solid-state drives in the eXFlash SSD units and 2.5-inch SSDs and HDDs. Drives are installed in the Storage Book. The x3950 X6 has two Storage Books. The Storage Book supports the following configurations:

  • 4x 2.5-inch hot-swap drive bays
  • 8x 2.5-inch hot-swap drive bays
  • 4x 2.5-inch hot-swap drive bays + 8x 1.8-inch hot-swap SSD bays
  • 8x 1.8-inch hot-swap SSD bays
  • 16x 1.8-inch hot-swap SSD bays

The following figure shows these configurations.

Internal drive configurations
Figure 6. Internal drive configurations

Backplanes

All standard models ship with four 2.5-inch SAS/SATA hot-swap hard disk drive bays. The following table shows the internal storage expansion options that are available.

Table 8. Internal storage expansion options
Part
number
Feature
code
DescriptionMaximum supported x3950 X6
44X4104A4A64x 2.5" HS 12Gb SAS HDD Backplane4
44X4106A4A78x 1.8" HS 12Gb SAS HDD Backplane4

The backplanes are connected to one or two RAID controllers or HBAs depending on the number and type of backplane that is installed. The adapters are installed in PCIe slots in the Storage Book, as shown in the following figure.

Storage Book
Figure 7. Storage Book

The following table shows the backplanes that are required per Storage Book and the number of controllers that are required. Note that the table shows the exact number of controllers supported for each drive/backplane configuration, no more, no fewer.

Table 9. Drive combinations per Storage Book
Drive combinationBackplanes requiredNumber of controllers
supported
4x 2.5-inch hot-swap drive bays1x 4x 2.5" HS 12Gb SAS HDD Backplane, 44X41041
8x 2.5-inch hot-swap drive bays2x 4x 2.5" HS 12Gb SAS HDD Backplane, 44X41041
4x 2.5-inch hot-swap drive bays +
8x 1.8-inch hot-swap SSD bays
1x 4x 2.5" HS 12Gb SAS HDD Backplane, 44X4104
1x 8x 1.8" HS 12Gb SAS HDD Backplane, 44X4106
2
8x 1.8-inch hot-swap SSD bays1x 8x 1.8" HS 12Gb SAS HDD Backplane, 44X41061
16x 1.8-inch hot-swap SSD bays2x 8x 1.8" HS 12Gb SAS HDD Backplane, 44X41062

Controllers for internal storage

The following table lists the RAID controllers, HBAs, and additional hardware and feature upgrades that are used for internal disk storage. The adapters are installed in slots in the Storage Book.

Table 10. RAID controllers and HBAs for internal storage

Part
number
Feature
code
DescriptionMaximum
supported
x3950 X6
Where
used
46C9110A3YZServeRAID M5210 SAS/SATA Controller4All models
47C8675A3YYN2215 SAS/SATA HBA for System x4-
Hardware upgrades for the ServeRAID M5210
47C8656A3Z0ServeRAID M5200 Series 1GB Cache/RAID 5 Upgrade4-
47C8660A3Z1ServeRAID M5200 Series 1GB Flash/RAID 5 Upgrade4-
47C8664A3Z2ServeRAID M5200 Series 2GB Flash/RAID 5 Upgrade4-
47C8668A3Z3ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade
Features on Demand upgrades for the ServeRAID M5210
47C8708A3Z6ServeRAID M5200 Series Zero Cache/RAID 5 Upgrade2-
47C8706A3Z5ServeRAID M5200 Series RAID 6 Upgrade2*-
47C8710A3Z7ServeRAID M5200 Series Performance Accelerator2*-
47C8712A3Z8ServeRAID M5200 Series SSD Caching Enabler2*-
* These M5210 features upgrades require a cache memory upgrade (47C8656, 47C8660, or 47C8664).

The ServeRAID M5210 SAS/SATA Controller has the following specifications:
  • Eight internal 12 Gbps SAS/SATA ports
  • Two x4 HD mini-SAS internal connectors (SFF-8643)
  • Supports connections to SAS/SATA drives and SAS Expanders
  • Supports RAID 0, 1, and 10
  • Supports RAID 5 and 50 with optional M5200 Series RAID 5 upgrades
  • Supports RAID 6 and 60 with the optional M5200 Series RAID 6 Upgrade
  • Supports 1 GB non-backed cache or 1 GB, 2 GB or 4 GB flash-backed cache
  • Up to 12 Gbps throughput per port
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS3108 12 Gbps ROC controller

The N2215 SAS/SATA HBA has the following specifications:
  • Eight internal 12 Gbps SAS/SATA ports
  • Two x4 HD mini-SAS internal connectors (SFF-8643)
  • Supports connections to SAS/SATA HDDs and SATA SSDs
  • Optimized for SSD performance
  • No RAID support
  • Up to 12 Gbps throughput per port
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS3008 12 Gbps controller

For more information, see the list of Lenovo Press Product Guides in the RAID adapters category at the following address:
http://lenovopress.com/systemx/raid


Internal drive options

The following table lists hard disk drive options for internal storage.

Table 11. Disk drive options for internal disk storage

Part
number
Feature
code
DescriptionMaximum
supported
x3950 X6
1.8" 6 Gb SATA HS Enterprise SSDs
41Y8366A4FSS3700 200GB SATA 1.8" MLC Enterprise SSD32
41Y8371A4FTS3700 400GB SATA 1.8" MLC Enterprise SSD32
1.8" 6 Gb SATA HS Enterprise Value SSDs
00AJ335A56V120GB SATA 1.8" MLC Enterprise Value SSD32
00AJ340A56W240GB SATA 1.8" MLC Enterprise Value SSD32
00AJ345A56X480GB SATA 1.8" MLC Enterprise Value SSD32
00AJ350A56Y800GB SATA 1.8" MLC Enterprise Value SSD32
00AJ455A58US3500 800GB SATA 1.8" MLC Enterprise Value SSD 32
2.5" 6 Gb SAS HS Enterprise SSDs
00AJ207A4UA200GB SAS 2.5" MLC G3HS Enterprise SSD16
00AJ212A4UB400GB SAS 2.5" MLC G3HS Enterprise SSD16
00AJ217A4UC800GB SAS 2.5" MLC G3HS Enterprise SSD16
00AJ222A4UD1.6TB SAS 2.5" MLC G3HS Enterprise SSD16
2.5" 6 Gb SATA HS Enterprise SSDs
00AJ156A4U3S3700 200GB SATA 2.5" MLC G3HS Enterprise SSD16
00AJ161A4U4S3700 400GB SATA 2.5" MLC G3HS Enterprise SSD16
00AJ166A4U5S3700 800GB SATA 2.5" MLC G3HS Enterprise SSD16
2.5" 6 Gb SATA HS Enterprise Value SSDs
00AJ395A577120GB SATA 2.5" MLC G3HS Enterprise Value SSD16
00AJ400A578240GB SATA 2.5" MLC G3HS Enterprise Value SSD16
00AJ405A579480GB SATA 2.5" MLC G3HS Enterprise Value SSD16
00AJ410A57A800GB SATA 2.5" MLC G3HS Enterprise Value SSD16
00FN278A5U6S3500 1.6TB SATA 2.5" MLC G3HS Enterprise Value SSD16
2.5" 6 Gb SATA HS Entry SSDs
00FN337AS0G240GB SATA 2.5" MLC G3HS Entry SSD16
00FN342AS0H480GB SATA 2.5" MLC G3HS Entry SSD16
00FN347AS0J960GB SATA 2.5" MLC G3HS Entry SSD16
2.5" 6 Gb NL SAS HS HDDs
00AJ121A4TT500GB 7.2K 6Gbps NL SAS 2.5" G3HS HDD16
00AJ086A4TU1TB 7.2K 6Gbps NL SAS 2.5'' G3HS HDD16
2.5" 6 Gb NL SATA HS HDDs
00AJ131A4TV250GB 7.2K 6Gbps NL SATA 2.5" G3HS HDD16
00AJ136A4TW500GB 7.2K 6Gbps NL SATA 2.5" G3HS HDD16
00AJ141A4TX1TB 7.2K 6Gbps NL SATA 2.5" G3HS HDD16
2.5" 15K 6 Gb SAS HS HDDs
00AJ126A4TS600GB 15K 6Gbps SAS 2.5" G3HS HDD16
00AJ081A4TR300GB 15K 6Gbps SAS 2.5" G3HS HDD16
00AJ111A4TQ146GB 15K 6Gbps SAS 2.5" G3HS HDD16
2.5" 10K 6 Gb SAS HS HDDs
00AJ146A4TP1.2TB 10K 6Gbps SAS 2.5" G3HS HDD16
00AJ071A4TN900GB 10K 6Gbps SAS 2.5" G3HS HDD16
00AJ091A4TM600GB 10K 6Gbps SAS 2.5" G3HS HDD16
00AJ096A4TL300GB 10K 6Gbps SAS 2.5" G3HS HDD16
2.5" 6 Gb SAS HS SEDs
00AJ116A4U2146GB 15K 6Gbps SAS 2.5" G3HS SED16
00AJ106A4TY300GB 10K 6Gbps SAS 2.5" G3HS SED16
00AJ101A4TZ600GB 10K 6Gbps SAS 2.5" G3HS SED16
00AJ076A4U0900GB 10K 6Gbps SAS 2.5" G3HS SED16
00AJ151A4U11.2TB 10K 6Gbps SAS 2.5'' G3HS SED16
2.5" 12 Gb SAS HS SSDs
00FN379AS7C200GB 12G SAS 2.5" MLC G3HS Enterprise SSD16
00FN389AS7E400GB 12G SAS 2.5" MLC G3HS Enterprise SSD16
00FN399AS7G800GB 12G SAS 2.5" MLC G3HS Enterprise SSD16
00FN409AS7J1.6TB 12G SAS 2.5" MLC G3HS Enterprise SSD16
2.5" 12 Gb SAS HS Enterprise SSD SEDs
00FN419AS7L400GB SED 12G SAS 2.5" MLC G3HS Enterprise SSD16
00FN424AS7M800GB SED 12G SAS 2.5" MLC G3HS Enterprise SSD16
2.5" 10K 12 Gb SAS HS HDDs
00NA241ASBF600GB 10K 12Gbps SAS 2.5" G3HS 512e HDD16
00NA251ASBH900GB 10K 12Gbps SAS 2.5" G3HS 512e HDD16
00NA261ASBK1.2TB 10K 12Gbps SAS 2.5" G3HS 512e HDD16
00NA271ASBM1.8TB 10K 12Gbps SAS 2.5" G3HS 512e HDD16
2.5" 12 Gb SAS HS SEDs
00NA281ASBP300GB 15K 12Gbps SAS 2.5" G3HS 512e SED16
00NA286ASBQ600GB 15K 12Gbps SAS 2.5" G3HS 512e SED16
00NA291ASBR600GB 10K 12Gbps SAS 2.5" G3HS 512e SED16
00NA296ASBS900GB 10K 12Gbps SAS 2.5" G3HS 512e SED16
00NA301ASBT1.2TB 10K 12Gbps SAS 2.5" G3HS 512e SED16
00NA306ASBU1.8TB 10K 12Gbps SAS 2.5" G3HS 512e SED16
2.5" 15K 12 Gb SAS HS Hybrid HDDs
00NA311ASBV300GB 15K 12Gbps SAS 2.5" G3HS 512e Hybrid16
00NA321ASBX600GB 15K 12Gbps SAS 2.5" G3HS 512e Hybrid16

Internal backup units

The server does not support internal tape drive options.

Optical drives

The server does not support internal optical drives.

I/O expansion options

The server supports up to 22 PCIe slots plus two dedicated Mezzanine LOM slots (24 total) as follows:

  • In each of the two Storage Books (standard in all models): Two PCIe 3.0 x8 slots for supported internal RAID controllers and SAS HBAs
  • In each of the two Primary I/O Books (standard in all models):
    • Two PCIe 3.0 x16 slots (x16-wired), half length, full height, up to 75 W of power
    • One PCIe 3.0 x16 (x8-wired), half length, full height, up to 75 W of power
    • One mezzanine LOM 2 (ML2) slot for network adapters with the new ML2 form factor (PCIe 3.0 x8)
  • Four optional I/O Books, each with three slots, all full height. Optional I/O Books are hot-swap capable.

The following figure shows the Primary I/O Book with the air baffle raised to show the internals.

Primary I/O Book
Figure 8. Primary I/O Book

Optional I/O Books can be either of:
  • Half-length I/O Book:
    • Two PCIe 3.0 x8 slots (x8 wired)
    • One PCIe 3.0 x16 slot (x16 wired)
  • Full-length I/O Book:
    • Two PCIe 3.0 x16 (x16 wired)
    • One PCIe 2.0 x8 slot (x4 wired)

In order for an I/O Book to be hot-swappable, all adapters that are installed in the book must support hot-swap and the operating system must also support hot-swap. These operating systems support hot-swap:
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2

The adapters listed in the following table support hot-swap.

Table 12. Adapters that support hot swap
Part numberFeature codeDescription
00D8540*A4XHEmulex Dual Port 10GbE SFP+ VFA IIIr for System x*
49Y7960A2ECIntel X520 Dual Port 10GbE SFP+ Adapter for System x
49Y7970A2EDIntel X540-T2 Dual Port 10GBaseT Adapter for System x
49Y42305767Intel Ethernet Dual Port Server Adapter I340-T2 for System x
49Y42405768Intel Ethernet Quad Port Server Adapter I340-T4 for System x
00AG500A56KIntel I350-F1 1xGbE Fiber Adapter for System x
00AG510A56LIntel I350-T2 2xGbE BaseT Adapter for System x
00AG520A56MIntel I350-T4 4xGbE BaseT Adapter for System x
* Hot-swap is only supported when the adapter is in pNIC mode. Hot-swap is not supported in either vNIC mode (Virtual Fabric mode or Switch Independent mode).

The use of two Optional I/O Books requires six processors to be installed. The usage of all four Optional I/O Books requires all eight processors to be installed.

The following table shows the ordering information for the optional I/O Books.

Table 13. I/O Book options
Part
number
Feature
code
DescriptionMaximum
supported
x3950 X6
44X4049A4A2X6 Half-Length I/O Book4
44X4051A4A3*X6 Full-Length I/O Book4
* The Full-length I/O Book can be ordered only as an option. It is not available through CTO because the Full-length I/O Book cannot be shipped installed in the server

The following figure shows the two optional I/O Books: the Half-length I/O Book and the Full-length I/O Book.

Half-length I/O Book and the Full-length I/O Book
Figure 9. Half-length I/O Book and the Full-length I/O Book

The following figure shows the Half-length I/O Book.

Half-length I/O Book
Figure 10. Half-length I/O Book

Each slot in the Half-length I/O Book and the Full-length I/O Book supplies up to 75 W of power.

The Full-length I/O Book also includes two auxiliary power connectors. With the usage of these connectors and the supplied power cords, the I/O book supports one double-wide adapter up to 300 W. The auxiliary power connectors are as follows:
  • One 2x4 power connector, which supplies up to 150 W of additional power to the adapter
  • One 2x3 power connector, which supplies up to 75 W of additional power to the adapter

The combined power consumption of all the adapters that are installed in the Full-length I/O Book cannot exceed 300 W.

Note: The 2x3 connector is intended to be used only when one adapter is installed in the first x16 slot (the up-most slot in the following figure), either requiring 225 W or 300 W of power. The location of the 2x3 connector prevents an adapter from being installed in the other x16 slot.

Full-length I/O Book
Figure 11. Full-length I/O Book

The Half-length I/O Book installs flush with the Primary I/O Book at the rear of the server. The Full-length I/O Book, when installed, adds a 99 mm (3.9 in.) mechanical extension to the base length dimension of the chassis.

The following figure shows a Full-length I/O Book and a Half-length I/O Book installed in the server.

Optional I/O Books installed (x3850 X6 shown)
Figure 12. Optional I/O Books that are installed (x3850 X6 shown)

Network adapters

The server supports ML2 adapters that are installed in the two ML2 slots, one in each Primary I/O Book. These ML2 slots support adapters with either two 10 Gb ports or four Gigabit ports and supports direct connectivity to the IMM2 service processor for out-of-band systems management.

As listed in Table 2, all standard models of the x3950 X6 include an Intel I350-T4 ML2 Quad Port GbE Adapter (I350-AM4 based).

The Intel I350-T4 ML2 Quad Port GbE Adapter has the following specifications:

  • Quad-port 1 Gb Ethernet connectivity
  • Intel I350-AM4 ASIC
  • Four RJ45 ports for copper cables

For more information about this adapter, see the Lenovo Press Product Guide found at the following address:
http://lenovopress.com/tips1155

The following table lists the supported ML2 adapters.

Table 14. ML2 adapters
Part numberFeature
code
DescriptionMaximum
supported
x3950 X6
00D2026A40SBroadcom NetXtreme II ML2 Dual Port 10GbaseT for System x2
00D2028A40TBroadcom NetXtreme II ML2 Dual Port 10GbE SFP+ for System x2
00D1996A40QEmulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter for System x2
00D8544A4NZEmulex VFA5 ML2 FCoE/iSCSI License for System x (FoD)
(Features on Demand upgrade for 00D1996 - one for each adapter)
2
00D1998A40RIntel I350-T4 ML2 Quad Port GbE Adapter for System x2
00D1994A40PIntel X540 ML2 Dual Port 10GbaseT Adapter for System x2
94Y5200AS74Intel X710 ML2 4x10GbE SFP+ Adapter for System x2
00FP650A5RKMellanox ConnectX-3 Pro ML2 2x40GbE/FDR VPI Adapter for System x2

The server also supports various other Ethernet and InfiniBand network adapters, as listed in the following table. The maximum quantity listed is for configurations with all processors and I/O books installed.

Table 15. Network adapters
Part
number
Feature
code
DescriptionMaximum
supported
x3950 X6
40 Gb Ethernet
00D9550A3PNMellanox ConnectX-3 40GbE / FDR IB VPI Adapter for System x18
10 Gb Ethernet
44T1370A5GZBroadcom NetXtreme 2x10GbE BaseT Adapter for System x18
49Y7910A18YBroadcom NetXtreme II Dual Port 10GBaseT Adapter for System x18
00JY820A5UTEmulex VFA5 2x10 GbE SFP+ PCIe Adapter for System x18
00JY830A5UUEmulex VFA5 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW for System x18
00JY824A5UVEmulex VFA5 FCoE/iSCSI SW for PCIe Adapter for System x (FoD)18
00D8540A4M9Emulex Dual Port 10GbE SFP+ VFA III-R for System x18
49Y7960A2ECIntel X520 Dual Port 10GbE SFP+ Adapter for System x18
49Y7970A2EDIntel X540-T2 Dual Port 10GBaseT Adapter for System x18
81Y3520AS73Intel X710 2x10GbE SFP+ Adapter for System x18
00D9690A3PMMellanox ConnectX-3 10 GbE Adapter for System x18
90Y4600A3MRQLogic 8200 Dual Port 10GbE SFP+ VFA for System x18
00Y5624A3MTQLogic 8200 VFA FCoE/iSCSI License for System x (FoD)18
47C9952A47HSolarflare SFN5162F 2x10GbE SFP+ Performant Adapter for System x18
47C9960A47JSolarflare SFN6122F 2x10GbE SFP+ Onload Adapter for System x18
Gigabit Ethernet
00AG500A56KIntel I350-F1 1xGbE Fiber Adapter for System x18
00AG510A56LIntel I350-T2 2xGbE BaseT Adapter for System x18
00AG520A56MIntel I350-T4 4xGbE BaseT Adapter for System x18
90Y9370A2V4Broadcom NetXtreme I Dual Port GbE Adapter for System x18
90Y9352A2V3Broadcom NetXtreme I Quad Port GbE Adapter for System x18
49Y42305767Intel Ethernet Dual Port Server Adapter I340-T2 for System x18
49Y42405768Intel Ethernet Quad Port Server Adapter I340-T4 for System x18
InfiniBand
00D9550A3PNMellanox ConnectX-3 40GbE / FDR IB VPI Adapter for System x18

For more information, see the list of Lenovo Press Product Guides in the Networking adapters category found at the following address:
http://lenovopress.com/systemx/networkadapters

Storage host bus adapters

The following table lists storage HBAs supported by the server. The maximum quantity listed is for configurations with all processors and I/O books installed.

Table 16. Storage adapters

Part numberFeature
code
DescriptionMaximum
supported
x3950 X6
Fibre Channel - 16 Gb
81Y1655A2W5Emulex 16Gb FC Single-port HBA for System x18
81Y1662A2W6Emulex 16Gb FC Dual-port HBA for System x18
81Y1668A2XUBrocade 16Gb FC Single-port HBA for System x18
81Y1675A2XVBrocade 16Gb FC Dual-port HBA for System x18
00Y3337A3KWQLogic 16Gb FC Single-port HBA for System x18
00Y3341A3KXQLogic 16Gb FC Dual-port HBA for System x18
Fibre Channel - 8 Gb
42D04853580Emulex 8 Gb FC Single-port HBA for System x18
42D04943581Emulex 8 Gb FC Dual-port HBA for System x18
42D05013578QLogic 8 Gb FC Single-port HBA for System x18
42D05103579QLogic 8 Gb FC Dual-port HBA for System x18
46M60493589Brocade 8 Gb FC Single-port HBA for System x18
46M60503591Brocade 8 Gb FC Dual-port HBA for System x18
SAS
46C9010A3MVN2125 SAS/SATA HBA for System x18
00AE912A5M0N2225 SAS/SATA HBA for System x18

For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category found at the following address:
http://lenovopress.com/systemx/hba

PCIe SSD adapters

The server supports the High IOPS SSD adapters that are listed in the following table. The maximum quantity listed is for configurations with all processors and I/O books installed.

Table 17. SSD adapters

Part numberFeature
code
DescriptionMaximum
supported
x3950 X6
46C9078A3J3365GB High IOPS MLC Mono Adapter18
46C9081A3J4785GB High IOPS MLC Mono Adapter18
90Y4377A3DY1.2TB High IOPS MLC Mono Adapter18
90Y4397A3DZ2.4TB High IOPS MLC Duo Adapter18
00AE995ARYP1000GB Enterprise io3 Flash Adapter12
00AE998ARYQ1300GB Enterprise io3 Flash Adapter12
00JY004ARYS5200GB Enterprise io3 Flash Adapter12
00JY001ARYR*2600GB Enterprise io3 Flash Adapter12
00AE983ARYK1250GB Enterprise Value io3 Flash Adapter12
00AE986ARYL1600GB Enterprise Value io3 Flash Adapter12
00AE989ARYM3200GB Enterprise Value io3 Flash Adapter12
00AE992ARYN*6400GB Enterprise Value io3 Flash Adapter12
* These adapters cannot be ordered via CTO. It can only be ordered as an option. The server cannot be shipped with this adapter installed. See http://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-IO3

For more information, about these adapters, see the Lenovo Press Product Guide High IOPS MLC Adapters, TIPS0907, found at the following address:
http://lenovopress.com/tips0907

GPU adapters

The server supports the co-processors and graphics processing units (GPUs) that are listed in the following table. Each is installed in a Full-length I/O Book. No other adapter can be installed in the Full-length I/O Book. The Full-length I/O Book includes the necessary auxiliary power cables.

Notes:

  • These adapters are not available through CTO and cannot be shipped installed in the server because they are installed in the Full-length I/O Book, which extends beyond the rear of the chassis (see Figure 12). These adapters must be shipped separately from the server. Order the adapter and Full-length I/O Book as separate options.
  • If a NVIDIA Grid K1, Grid K2, Tesla K20c, Tesla K40, Quadro K4000 or Quadro K6000 is installed, the maximum system memory that can be installed is 1 TB.

Table 18. GPU adapters
Part numberFeature codeDescriptionMinimum
system
RAM
Maximum
supported
x3950 X6
00FP670A4G4*Intel Xeon Phi 3120A12 GB4
00J6160A3GM*NVIDIA GRID K132 GB4
00FP674A470*NVIDIA Grid K2 (Actively Cooled)16 GB4
00FP675A3YU*NVIDIA Quadro K40006 GB4
00FP672A3YV*NVIDIA Quadro K600024 GB4
00FP673A471*NVIDIA Tesla K20 (Actively Cooled)10 GB4
00FP676A5FG*NVIDIA Tesla K40c24 GB4
* Not available through CTO.

Power supplies

The x3950 X6 supports up to eight redundant power supplies. Standard models come with four power supplies (model dependent). The following table lists the power supplies.

Table 19. Power supplies

Part numberFeature
code
DescriptionMaximum
supported
x3950 X6
Standard models
where used
44X4150A54D1400W HE Redundant Power Supply
for altitudes >5000 meters
8All HANA models
44X4152A54E1400W HE Redundant Power Supply8-
44X4132A4R0900W Power Supply8BAx, CAx, CCx
88Y7433A2EA750W High Efficiency -48 V DC Power Supply8-

An AC power supply ships standard with one 2.8 m C13 - C14 power cord.

Integrated virtualization

The server supports VMware ESXi that is installed on a USB memory key. The key is installed in a USB socket that is on the primary I/O book inside the server. The following table lists the virtualization options.

Table 20. Virtualization options

Part numberFeature
code
DescriptionMaximum
supported*
41Y8298A2G0Blank USB Memory Key for VMware ESXi Downloads1 / 2
41Y8382A4WZUSB Memory Key for VMware ESXi 5.1 U11 / 2
* 2 hypervisor keys are supported only if the x3950 X6 is configured to be partitioned, where the two halves of the server operate as two independent four-socket servers. However, CTO orders can include only one hypervisor key.

Systems management

The server contains Integrated Management Module II (IMM2), which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. The IMM2 also provides a virtual presence capability for remote server management capabilities.

The IMM2 provides remote server management through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3
  • Common Information Model (CIM)
  • Web browser

The remote presence provides the following functions:
  • Remotely viewing video with graphics resolutions up to 1600 x 1200 at 75 Hz with up to 23 bits per pixel colors, regardless of the system state
  • Remotely accessing the server by using the keyboard and mouse from a remote client
  • Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
  • Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive

The blue-screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating-system hang condition. A system administrator can use the blue-screen capture feature to assist in determining the cause of the hang condition.

Supported operating systems

The server supports the following operating systems:

  • Microsoft Windows Server 2008 R2
  • Microsoft Windows Server 2012
  • Microsoft Windows Server 2012 R2
  • Red Hat Enterprise Linux 6 Server x64 Edition
  • Red Hat Enterprise Linux 7
  • SUSE Enterprise Linux Server (SLES) 12
  • SUSE LINUX Enterprise Server 11 for AMD64/EM64T
  • SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
  • SUSE Linux Enterprise Server 12 with XEN
  • VMware vSphere 5.1 (ESXi) (Limited to 160 threads)
  • VMware vSphere 5.5 (ESXi)

For the latest information about the specific versions and service levels that are supported and any other prerequisites, see the ServerProven® website at the following address:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

Physical and electrical specifications

Dimensions and weight:

  • Height: 351 mm (13.7 in.)
  • Width: 482 mm (19.0 in.)
  • Depth: 804 mm (31.6 in)
  • Depth with cable management brackets installed: 836 mm (32.9”)
  • Depth with Full-length I/O Book installed: 921 mm (36.2 in)
  • Weight:
    • Minimum configuration: 84.5 kg (186.3 lb)
    • Typical configuration: 88.2 kg (194.5 lb)
    • Maximum configuration: 110.0 kg (242.6 lb)

Supported environment:
  • Air temperature:
    • Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 - 3,050 m (10,000 ft).
    • Server off: 5 °C to 45 °C (41 °F to 113 °F); altitude: 0 - 3,050 m (10,000 ft).
    • Shipment: -40 °C to 60 °C (-40 °F to 140 °F)
  • Humidity:
    • Server on: 8% - 85%, maximum dew point 24 °C
    • Server off: 8% - 85%, maximum dew point 27 °C
  • Electrical:
    • Models with 1400 W AC power supplies:
      • 100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 10 A (900 W DC output)
      • 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 8 A (1400 W DC output)
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.16 kVA
        • Maximum configuration: 3.2 kVA
    • Models with 900 W AC power supplies:
      • 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 10.7 A
      • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 5.3 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.16 kVA
        • Maximum configuration: 2.0 kVA
    • Models with 750 W DC power supplies:
      • -40 to -75 (nominal) V DC
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.16 kVA
        • Maximum configuration: 1.7 kVA
  • BTU output:
    • Minimum configuration: 546 Btu/hr (160 watts)
    • Maximum configuration: 10,912 Btu/hr (3,200 watts)
  • Noise level:
    • 6.6 bels (operating)
    • 6.4 bels (idle)

Warranty options

The System x3950 X6 has a three-year onsite warranty with 9x5/next business day terms. Lenovo offers the warranty service upgrades through ServicePac offerings. ServicePac is a series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

ServicePac offerings are country-specific, that is, each country might have its own service types, service levels, response times, and terms and conditions. Not all covered types of ServicePac offerings might be available in a particular country. For more information about the ServicePac offerings that are available in your country, visit the ServicePac Product Selector at the following address:

https://www-304.ibm.com/sales/gss/download/spst/servicepac

The following table explains the warranty service definitions in more detail.

Table 21. Warranty service definitions

TermDescription
Onsite repairA service technician comes to the server's location for equipment repair.
24x7x2 hourA service technician is scheduled to arrive at your customer’s location within two hours after remote problem determination is complete. We provide service around the clock, every day, including holidays.
24x7x4 hourA service technician is scheduled to arrive at your customer’s location within four hours after remote problem determination is complete. We provide service around the clock, every day, including holidays.
9x5x4 hourA service technician is scheduled to arrive at your customer’s location within four business hours after remote problem determination is completed. We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding holidays. If after 1:00 p.m. it is determined that onsite service is required, the customer can expect the service technician to arrive the morning of the following business day. For noncritical service requests, a service technician arrives by the end of the following business day.
9x5 next business dayA service technician is scheduled to arrive at your customer’s location on the business day after we receive your call, following remote problem determination. We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding holidays.

In general, the types of ServicePacs are as follows:
  • Warranty and maintenance service upgrades:
    • One, 2, 3, 4, or 5 years of 9x5 or 24x7 service coverage
    • Onsite repair from next business day to 4 or 2 hours
    • One or two years of warranty extension
  • Remote technical support services:
    • One or three years with 24x7 coverage (severity 1) or 9x5/next business day for all severities
    • Installation and start-up support for System x servers
    • Remote technical support for System x servers
    • Software support - Support Line:
      • Microsoft or Linux software
      • VMware
      • IBM Systems Director

Regulatory compliance

The server conforms to the following regulations:

  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 4, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • Australia/New Zealand AS/NZS CISPR 22, Class A
  • IEC 60950-1(CB Certificate and CB Test Report)
  • China CCC (GB4943), GB9254 Class A, GB17625.1
  • Taiwan BSMI CNS13438, Class A; CNS14336-1
  • Korea KN22, Class A; KN24
  • Russia/GOST ME01, IEC-60950-1, GOST R 51318.22, GOST R 51318.24, GOST R 51317.3.2, and GOST R 51317.3.3
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
  • CISPR 22, Class A
  • TUV-GS (EN60950-1 /IEC60950-1, EK1-ITB2000)

External disk storage expansion

The server supports attachment to external storage expansion enclosures, such as the EXP2500 series, by using the ServeRAID M5120 SAS/SATA Controller. The server can also be attached to supported external storage systems, such as the IBM DS3500 series, by using a supported HBA (see the earlier "Storage HBA" section). The following table shows the RAID controllers and options for external disk storage expansion.

Table 22. RAID controllers and options for external disk storage expansion

Part numberFeature
code
DescriptionMaximum
supported
x3950 X6
Standard models
where used
00AE938A5NDServeRAID M5225-2GB SAS/SATA Controller6-
81Y4478A1WXServeRAID M5120 SAS/SATA Controller5-
Features on Demand upgrades for the M5225
47C8706A3Z5ServeRAID M5200 Series RAID 6 Upgrade for Systems-FoD1
47C8710A3Z7ServeRAID M5200 Series Performance Accelerator for Systems-FoD1
47C8712A3Z8ServeRAID M5200 Series SSD Caching Enabler for Systems-FoD1
Hardware upgrades for the M5120
81Y4487A1J4ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade1-
81Y4559A1WYServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade1-
47C8670A4G6ServeRAID M5100 Series 2GB Flash/RAID 5 Upgrade for System x1
Feature on Demand upgrades for the M5120
90Y4318A2MDServeRAID M5100 Series SSD Caching Enabler1*-
90Y4273A2MCServeRAID M5100 Series SSD Performance Key1*-
81Y4546A1X3ServeRAID M5100 Series RAID 6 Upgrade1*-
* These M5120 features upgrades require a cache memory upgrade (81Y4487, 81Y4559, or 47C8670).

The ServeRAID M5225 SAS/SATA Controller has the following specifications:
  • Eight external 12 Gbps SAS/SATA ports
  • Supports 12, 6, and 3 Gbps SAS and 6 and 3 Gbps SATA data transfer rates
  • Two external x4 mini-SAS HD connectors (SFF-8644)
  • Supports 2 GB flash-backed cache (standard)
  • Supports RAID levels 0, 1, 5, 10, and 50 (standard)
  • Supports RAID 6 and 60 with the optional M5200 Series RAID 6 Upgrade
  • Supports optional M5200 Series Performance Accelerator and SSD Caching upgrades
  • PCIe x8 Gen 3 host interface
  • Based on the LSI SAS3108 12 Gbps ROC controller
  • Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures

For more information about the ServeRAID M5225, see the Lenovo Press Product Guide at http://lenovopress.com/tips1258

The ServeRAID M5120 SAS/SATA Controller has the following specifications:
  • Eight external 6 Gbps SAS/SATA ports
  • Up to 6 Gbps throughput per port
  • Two external x4 mini-SAS connectors (SFF-8088)
  • Supports RAID 0, 1, and 10
  • Supports RAID 5 and 50 with optional M5100 Series RAID 5 upgrades
  • Supports RAID 6 and 60 with the optional M5100 Series RAID 6 upgrade
  • Supports 512 MB or 1 GB flash-backed cache
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS2208 6 Gbps ROC controller
  • Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures

Cache upgrade required: The ServeRAID M5120 SAS/SATA Controller ships standard without a cache. One of the available cache upgrades (81Y4487, 81Y4559, or 47C8670) is required for the M5120 adapter operations, and it must be purchased together with the controller.

For more information about the ServeRAID M5120, see the Lenovo Press Product Guide at http://lenovopress.com/tips0858

The controllers support connectivity to the IBM storage system external expansion enclosures that are listed in the following table. Up to nine expansion enclosures can be daisy-chained per one controller external port. For better performance, distribute expansion enclosures evenly across both controller ports.

Table 23. External expansion enclosures
Part numberDescriptionMaximum quantity
supported per one controller
70F0 / 70F1Lenovo ThinkServer SA1208
610012XEXP2512 Express18
610024XEXP2524 Express9

Lenovo ThinkServer SA120 support

For details about supported drives and cables for the Lenovo ThinkServer SA120, see the Lenovo Press Product Guide:
http://lenovopress.com/tips1234

EXP2512 and EXP2524 support

The external SAS cables that are listed in the following table support connectivity between external expansion enclosures and the controller.

Table 24. External SAS cables for external storage expansion enclosures
Part numberDescriptionMaximum quantity supported
per one enclosure
ServeRAID M5120 - Server to Expansion enclosure connectivity (Mini-SAS x4 to Mini-SAS x4)
39R65291 m SAS Cable1
39R65313 m SAS Cable1
ServeRAID M5225 - Server to Expansion enclosure connectivity (Mini-SAS HD x4 to Mini-SAS x4)
00MJ1620.6m SAS Cable (mSAS HD to mSAS)1
00MJ1631.5m SAS Cable (mSAS HD to mSAS)1
00MJ1663m SAS Cable (mSAS HD to mSAS)1
90Y7682External Expansion Cable - 6M SAS Cable - HD SAS to Mini SAS1
Expansion enclosure to Expansion enclosure connectivity (Mini-SAS x4 to Mini-SAS x4)
39R65291 m SAS Cable1
39R65313 m SAS Cable1

The following table lists the drives that are supported by EXP2512 external expansion enclosures.

Table 25. Drive options for EXP2512 external expansion enclosures
Part numberDescriptionMaximum quantity supported
per one enclosure
3.5" NL SAS HS HDDs
00NC5552TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
00NC5573TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
00NC5594TB 7,200 rpm 6Gb SAS NL 3.5" HDD12

The following table lists the hard disk drives that are supported by EXP2524 external expansion enclosures.

Table 26. Drive options for EXP2524 external expansion enclosures
Part numberDescriptionMaximum quantity supported
per one enclosure
2.5" NL SAS HS HDDs
00NC5711TB 7,200 rpm 6Gb SAS NL 2.5" HDD24
2.5" SAS HS HDDs
00NC561146GB 15,000 rpm 6Gb SAS 2.5" HDD24
00NC563300GB 15,000 rpm 6Gb SAS 2.5" HDD24
00NC565600GB 10,000 rpm 6Gb SAS 2.5" HDD24
00NC567900GB 10,000 rpm 6Gb SAS 2.5" HDD24
00NC5691.2TB 10,000 rpm 6Gb SAS 2.5" HDD24
2.5" SAS HS SSDs
00NC573200GB 6Gb SAS 2.5" SSD24
00NC575400GB 6Gb SAS 2.5" SSD24

External disk storage systems

The following table lists the external storage systems that are supported by the server and can be ordered through the System x sales channel. The server might support other disk systems that are not listed in this table. For more information, see the IBM System Storage Interoperation Center found at http://www.ibm.com/systems/support/storage/ssic.

Table 27. External disk storage systems

Part numberDescription
2071CU2Storwize V3500 LFF Dual Control Enclosure
2071CU3Storwize V3500 SFF Dual Control Enclosure
6099L2CStorwize V3700 3.5-inch Storage Controller Unit
6099S2CStorwize V3700 2.5-inch Storage Controller Unit
6099T2CStorwize V3700 2.5-inch DC Storage Controller Unit

For more information, see the list of Lenovo Press Product Guides in the System Storage category found at http://lenovopress.com/systemx/externalstorage


External backup units

The server supports the external backup attachment options that are listed in the following table.

Table 28. External backup options

Part numberDescription
External tape expansion enclosures for internal tape drives
87651UX1U Tape Drive Enclosure
8767HHXHalf High Tape Drive Enclosure
87651NX1U Tape Drive Enclosure (with Nema 5-15P LineCord)
8767HNXHalf High Tape Drive Enclosure (with Nema 5-15P LineCord)
Tape enclosure adapters (with cables)
40K2599SAS Enclosure Adapter Kit
Internal backup drives supported by external tape enclosures
49Y9898Half High LTO Gen 5 Internal SAS Tape Drive
00D8924Half High LTO Ultrium Gen 6 Internal SAS Tape Drive
External backup units*
36251TYRDX External USB 3.0 Dock with 1TB Cartridge
362532YRDX External USB 3.0 Dock with 320GB Cartridge
362550YRDX External USB 3.0 Dock with 500GB Cartridge
3628L5X Half High LTO Gen 5 External SAS Tape Drive (with US power cord)
3628N4XHalf High LTO Gen 4 External SAS Tape Drive (without power cord)
3628N5XHalf High LTO Gen 5 External SAS Tape Drive (without power cord)
3580S3VSystem Storage TS2230 Tape Drive Express Model H3V
3580S4VSystem Storage TS2240 Tape Drive Express Model H4V
3580S5ESystem Storage TS2250 Tape Drive Express Model H5S
3580S5XSystem Storage TS2350 Tape Drive Express Model S53
3572S4RTS2900 Tape Library with LTO4 HH SAS drive & rack mount kit
3572S5RTS2900 Tape Library with LTO5 HH SAS drive & rack mount kit
35732ULTS3100 Tape Library Model L2U Driveless
35734ULTS3200 Tape Library Model L4U Driveless
46X2682†LTO Ultrium 5 Fibre Channel Drive
46X2683†LTO Ultrium 5 SAS Drive Sled
46X2684†LTO Ultrium 5 Half High Fibre Drive Sled
46X2685†LTO Ultrium 5 Half High SAS Drive Sled
46X6912†LTO Ultrium 4 Half High Fibre Channel Drive Sled
46X7117†LTO Ultrium 4 Half High SAS DriveV2 Sled
46X7122†LTO Ultrium 3 Half High SAS DriveV2 Sled
* Note: The external tape drives that are listed can be ordered through the System x sales channel. The server might support other tape drives that are not listed in this table. For more information, see the IBM System Storage Interoperability Center.
† Note: These part numbers are the tape drives options for 35732UL and 35734UL.

For more information, see the list of Lenovo Press Product Guides in the Backup units category found at the following address:
http://lenovopress.com/systemx/tape


Top-of-rack Ethernet switches

The server supports the top-of-rack Ethernet switches from Lenovo in the following table.

Table 29. Top-of-rack switches

Part numberDescription
1 Gb top-of-rack switches
7309BAXRackSwitch G7028 (24 ports)
7309CAXRackSwitch G7028 (48 ports)
0446013RackSwitch G8000R
7309CFCRackSwitch G8000F
7309G52RackSwitch G8052R
730952FRackSwitch G8052F
10 Gb top-of-rack switches
7309DRXRackSwitch G8264CS (Rear to Front)
7309DFXRackSwitch G8264CS (Front to Rear)
7309BR6RackSwitch G8124ER
7309BF7RackSwitch G8124EF
7309G64RackSwitch G8264R
730964FRackSwitch G8264F
7309CR9RackSwitch G8264TR
7309CF9RackSwitch G8264TF
40 Gb top-of-rack switches
8036BRXRackSwitch G8332 (Rear to Front)
8036BFXRackSwitch G8332 (Front to Rear)
8036ARXRackSwitch G8316R
8036AFXRackSwitch G8316F

For more information, see the list of Lenovo Press Product Guides in the Top-of-rack switches category:
http://lenovopress.com/systemx/tor

Uninterruptible power supply units

The server supports attachments to the uninterruptible power supply (UPS) units that are listed in the following table.

Table 30. Uninterruptible power supply units

Part numberDescription
Rack-mounted or tower UPS units
55941AXRT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KXRT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AXRT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KXRT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AXRT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KXRT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KXRT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KXRT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KXRT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KXRT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PXRT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PXRT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
Rack-mounted UPS units
53951AX1500VA LCD 2U Rack UPS (100V/120V)
53951KX1500VA LCD 2U Rack UPS (230V)
53952AX2200VA LCD 2U Rack UPS (100V/120V)
53952KX2200VA LCD 2U Rack UPS (230V)
53953AX 3000VA LCD 3U Rack UPS (100 V/120 V)
53953JX 3000VA LCD 3U Rack UPS (200 V/208 V)
53956AX 6000VA LCD 4U Rack UPS (200 V/208 V)
53956KX 6000VA LCD 4U Rack UPS (230 V)
53959KX11000VA LCD 5U Rack UPS (200V/208V/230V)

For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category found at the following address:
http://lenovopress.com/systemx/power


Power distribution units

The server supports attachments to the power distribution units (PDUs) that are listed in the following table.

Table 31. Power distribution units

Part numberDescription
Switched and Monitored PDUs
46M4002 1U 9 C19/3 C13 Active Energy Manager DPI PDU
46M4003 1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU
46M4004 1U 12 C13 Active Energy Manager DPI PDU
46M4005 1U 12 C13 Active Energy Manager 60A 3 Phase PDU
46M41671U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU
46M41160U 24 C13 Switched and Monitored 30A PDU
46M41190U 24 C13 Switched and Monitored 32A PDU
46M41340U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU
46M41370U 12 C19/12 C13 Switched and Monitored 32A 3 Phase PDU
Enterprise PDUs
71762MX Ultra Density Enterprise PDU C19 PDU+ (WW)
71762NX Ultra Density Enterprise PDU C19 PDU (WW)
71763MU Ultra Density Enterprise PDU C19 3 Phase 60A PDU+ (NA)
71763NU Ultra Density Enterprise PDU C19 3 Phase 60A PDU (NA)
39M2816DPI C13 Enterprise PDU without power cord
39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed power cord
39Y8941 DPI Single Phase C13 Enterprise PDU without power cord
39Y8948 DPI Single Phase C19 Enterprise PDU without power cord
Front-end PDUs
39Y8934DPI 32 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector
39Y8935DPI 63 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector
39Y893830 amp/125 V Front-end PDU with NEMA L5-30P connector
39Y893930 amp/250 V Front-end PDU with NEMA L6-30P connector
39Y894060 amp/250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector
Universal PDUs
39Y8951DPI Universal Rack PDU with US LV and HV power cords
39Y8952DPI Universal Rack PDU with CEE7-VII Europe LC
39Y8953DPI Universal Rack PDU with Denmark LC
39Y8954DPI Universal Rack PDU with Israel LC
39Y8955 DPI Universal Rack PDU with Italy LC
39Y8956DPI Universal Rack PDU with South Africa LC
39Y8957DPI Universal Rack PDU with UK LC
39Y8958DPI Universal Rack PDU with AS/NZ LC
39Y8959DPI Universal Rack PDU with China LC
39Y8962DPI Universal Rack PDU (Argentina)
39Y8960DPI Universal Rack PDU (Brazil)
39Y8961DPI Universal Rack PDU (India)
0U Basic PDUs
46M41220U 24 C13 16A 3 Phase PDU
46M4125 0U 24 C13 30A 3 Phase PDU
46M4128 0U 24 C13 30A PDU
46M41310U 24 C13 32A PDU
46M4140 0U 12 C19/12 C13 60A 3 Phase PDU
46M41430U 12 C19/12 C13 32A 3 Phase PDU

For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category found at the following address:
http://lenovopress.com/systemx/power

Rack cabinets

The server supports the rack cabinets that are listed in the following table.

Table 32. Rack cabinets

Part numberDescriptionSupported
by x3950 X6
Maximum
supported
x3950 X6
2018-86X11U Office Enablement KitNoNot applicable
9307-2PX25U Static S2 Standard RackNoNot applicable
9307-2RX25U Standard Rack NoNot applicable
9307-4RX42U Standard Rack NoNot applicable
9307-4XX42U Standard Rack ExtensionNoNot applicable
9308-4EX42U Enterprise Expansion RackYes*5
9308-4PX42U Enterprise RackYes*5
9360-4PX42U 1200mm Deep Dynamic RackYes5
9360-4EX42U 1200mm Deep Dynamic Expansion RackYes5
9361-4PX42U 1200mm Deep Static RackYes5
9361-4EX42U 1200mm Deep Static Expansion RackYes5
9362-4PX47U 1200mm Deep Static RackYes5
9362-4EX47U 1200mm Deep Static Expansion RackYes5
9363-4CXPureFlex System 42U RackYes5
9363-4DXPureFlex System 42U Expansion RackYes5
9363-4PX42U 1100mm Dynamic RackYes5
9363-4EX42U 1100mm Dynamic Expansion RackYes5
1410-2RXIntelligent Cluster 25U Rack FamilyNoNot applicable
1410-4RXIntelligent Cluster 42U Rack FamilyYes*5
1410-PRAIntelligent Cluster 42U 1200mm Deep Rack FamilyYes5
1410-PRBIntelligent Cluster 42U 1100mm Enterprise V2 Rack FamilyYes5
7200-4PXSmart Analytics 42U Rack FamilyYes*5
* No support for Full-length I/O Books

For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category found at the following address:
http://lenovopress.com/systemx/rack

Rack options

The server supports the rack console switches and monitor kits that are listed in the following table.

Table 33. Rack options

Part numberFeature codeDescription
Monitor kits and keyboard trays
17238BXA3EK1U 18.5" Standard Console
17238EXA3EL1U 18.5" Enhanced Media Console
172317X00511U 17in Flat Panel Console Kit
172319X00521U 19in Flat Panel Console Kit
Console switches
3858D3X3858HC1 fc A4X1Avocent Universal Management Gateway 6000
1754D2X6695Global 4x2x32 Console Manager (GCM32)
1754D1X6694Global 2x2x16 Console Manager (GCM16)
1754A2X0726Local 2x16 Console Manager (LCM16)
1754A1X0725Local 1x8 Console Manager (LCM8)
Console cables
43V61473757Single Cable USB Conversion Option (UCO)
39M28953756USB Conversion Option (4 Pack UCO)
46M53835341Virtual Media Conversion Option Gen2 (VCO2)
46M53825340Serial Conversion Option (SCO)

For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category: http://lenovopress.com/systemx/rack

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovo.com/services_warranty/us/en/financial_services.html

Related publications and links

For more information, see these resources:


Special Notices

This material has not been submitted to any formal IBM test and is published AS IS. It has not been the subject of rigorous review. IBM assumes no responsibility for its accuracy or completeness. The use of this information or the implementation of any of these techniques is a client responsibility and depends upon the client's ability to evaluate and integrate them into the client's operational environment.

Profile

Publish Date
18 February 2014

Last Update
18 March 2015


Rating: Not yet rated


Author(s)

IBM Form Number
TIPS1132