The System x3650 M4 BD server offers a cost-effective, high-capacity storage solution with exceptional energy-smart design, leadership virtualization, and powerful systems management. It supports up to two Intel Xeon processor E5-2600 v2 family processors and high-density memory designs with 16 DDR3 DIMM slots. This 2U server is built on X-Architecture®, and it consolidates storage and server into one system, offers easy management, and saves floor space and power consumption, costing less money than traditional enterprise offerings.

Suggested use: Big data, email and collaboration applications, databases, virtualization and cloud, virtual desktops, and virtual storage.

Changes in the June 3 update:
* Updated the top-of-rack switch table
* Updated the warranty section with the latest Warranty Services information


IBM System x3650 M4 BD video walk-through

Contents


Table of contents


Introduction

The System x3650 M4 BD server offers a cost-effective, high-capacity storage solution with exceptional energy-smart design, leadership virtualization, and powerful systems management. It supports up to two Intel Xeon processor E5-2600 v2 family processors and high-density memory designs with 16 DDR3 DIMM slots. This 2U server is built on X-Architecture®, and it consolidates storage and server into one system, offers easy management, and saves floor space and power consumption, costing less money than traditional enterprise offerings.

Suggested use: Big data, email and collaboration applications, databases, virtualization and cloud, virtual desktops, and virtual storage.

The following figure shows the System x3650 M4 BD.

The IBM System x3650 M4 BD
Figure 1. The System x3650 M4 BD

Did you know?

The System x3650 M4 BD server is designed to provide exceptional value and flexibility to meet "big data" requirements and general business and storage-demanding applications, with up to 84 TB of storage space in a dense 2U form factor, Intel Xeon E5-2600 v2 product family processors, two DIMMs per channel running at up to 1866 MHz, and 80 PLUS certified power supplies.

The flexible onboard Ethernet solution provides three integrated Gigabit Ethernet ports, one dedicated systems management port, and an optional embedded 10 GbE ports.

Comprehensive systems management tools with the next-generation Integrated Management Module II (IMM2) make it easy to deploy, integrate, service, and manage.

Key features

Backed by worldwide service and support, the x3650 M4 BD is developed, quality-tested, and certified by IBM, the leading vendor in technology patents for 20 years running. System x® advancements in scalability, reliability, and performance can help your business innovate and thrive. With more flexible configuration options, energy-efficient components, and robust systems management tools, the x3650 M4 BD is an innovative design by Lenovo that can deliver business value over the long term.

Scalability and performance

The x3650 M4 BD offers numerous features to boost performance, improve scalability, and reduce costs:

  • The Intel Xeon processor E5-2600 v2 product family improves productivity by offering superior system performance with up to 12-core processors (up to 2.4 GHz core speeds) or up to 2.8 GHz core speeds (10-core processors), up to 30 MB of L3 cache, and QPI interconnect links of up to 8 GTps.
  • Up to two processors, 24 cores, and 48 threads maximize the concurrent running of multithreaded applications.
  • Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
  • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Intel Advanced Vector Extensions (AVT) improve floating point performance for compute-intensive technical and scientific applications.
  • Support for up to 512 GB of memory through 16 DIMM slots with 32 GB LRDIMMs.
  • Support for two DIMMs per channel running at 1866 MHz to help maximize system performance.
  • The use of solid-state drives (SSDs) instead of, or along with, traditional spinning drives (HDDs) can improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
  • The server offers three integrated Gigabit Ethernet ports, one dedicated 1 GbE management port, and optional embedded 10 GbE ports for flexible network connectivity.
  • The server offers PCI Express (PCIe) 3.0 I/O expansion capabilities that improve the theoretical maximum bandwidth by almost 100% (8 GTps per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GTps per link using 8b/10b encoding).
  • With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E5 family. This controller helps to reduce I/O latency and increase overall system performance.
  • Up to fourteen 3.5-inch hot-swap drive bays provide maximum internal storage density of up to 84 TB in a 2U form factor.

Availability and serviceability

The x3650 M4 BD provides many features to simplify serviceability and increase system uptime:
  • The server offers Chipkill, memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure to prevent an unplanned outage.
  • Tool-less cover removal provides easy access to upgrades and serviceable parts, such as processor, memory, and adapters.
  • The server offers hot-swap drives supporting basic and advanced hardware RAID redundancy for data protection and greater system uptime.
  • The server offers up to two redundant hot-swap power supplies and three dual-motor non-hot-swap redundant fans to provide cost-efficient availability for applications.
  • The light path diagnostics with individual light path LEDs quickly lead the technician to failed (or failing) components, simplifying servicing, speeding up problem resolution, and helping improve system availability.
  • Predictive Failure Analysis (PFA) detects when system components (processors, memory, hard disk drives, fans, and power supplies) operate outside of standard thresholds and generates proactive alerts in advance of a possible failure, therefore increasing uptime.
  • Solid-state drives (SSDs) offer better reliability than traditional mechanical HDDs for greater uptime.
  • The built-in Integrated Management Module II (IMM2) continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failure, to minimize downtime.
  • Built-in diagnostic tests using Dynamic Systems Analysis (DSA) Preboot speeds up troubleshooting tasks to reduce service time.
  • Three-year customer replaceable unit and onsite limited warranty, next business day 9x5. Optional service upgrades are available.

Manageability and security

Powerful systems management features simplify local and remote management of the x3650 M4 BD:
  • The server includes an Integrated Management Module II (IMM2) to monitor server availability and perform remote management.
  • An integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
  • Integrated Trusted Platform Module (TPM) V1.2 support enables advanced cryptographic functions, such as digital signatures and remote attestation.
  • IBM Systems Director is supported for proactive systems management. It offers comprehensive systems management tools that help increase uptime, reduce costs, and improve productivity through advanced server management capabilities.
  • Industry-standard AES NI support provides faster and stronger encryption.
  • The Intel Execute Disable Bit function can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space that is protected from all other software running on a system.

Energy efficiency

The x3650 M4 BD offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to a green environment:
  • Energy-efficient system board components help lower operational costs.
  • The x3650 M4 BD is Energy Star 2.0 compliant. Energy Star is the trusted, US government-backed symbol for energy efficiency, with the goal of helping customers save money and protect the environment through energy efficient products and practices. For the Power and Performance Data Sheet, see http://ibm.com/systems/x/hardware/energy-star
  • 80 PLUS certified power supplies enable greater energy savings while providing flexibility to meet your business needs.
  • The Intel Xeon processor E5-2600 v2 product family offers better performance over the previous generation, while fitting into the same TDP limits.
  • Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw.
  • Low-voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally constrained data centers and telecommunication environments.
  • Low-voltage 1.35 V DDR3 memory RDIMMs consume 19% less energy compared to 1.5 V DDR3 RDIMMs.
  • Solid-state drives (SSDs) consume as much as 80% less power than traditional spinning HDDs.
  • The server uses hexagonal ventilation holes, a part of Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, providing more efficient airflow through the system.
  • IBM Systems Director Active Energy Manager™ provides advanced data center power notification and management to help achieve lower heat output and reduced cooling needs.

Locations of key components and connectors

The following figure shows the front of the server.

Front view of the IBM System x3650 M4 BD
Figure 2. Front view of the System x3650 M4 BD

The following figure shows the rear of the server.

Rear view of the IBM System x3650 M4 BD
Figure 3. Rear view of the System x3650 M4 BD

The following figure shows the locations of key components inside the server.

Inside view of the IBM System x3650 M4 BD
Figure 4. Inside view of the System x3650 M4 BD (with the rear drive cage removed)

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications

ComponentsSpecification
Machine type5466
Form factor2U rack.
ProcessorUp to two Intel Xeon processor E5-2600 v2 product family processors with 12 cores (up to 2.4 GHz), 10 cores (up to 2.8 GHz), eight or six cores (up to 2.6 GHz) or four cores (up to 2.5 GHz), one QPI link up to 8.0 GTps, up to 1866 MHz memory speed, up to 30 MB L3 cache.
ChipsetIntel C602J.
MemoryUp to 16 DIMM sockets (eight DIMMs per processor). UDIMMs, RDIMMs, and LRDIMMs are supported, but memory types cannot be intermixed. DIMM speeds are up to 1866 MHz.
Memory maximumsWith UDIMMs: Up to 128 GB with 16x 8 GB UDIMMs and two processors
With RDIMMs: Up to 256 GB with 16x 16 GB RDIMMs and two processors
With LRDIMMs: Up to 512 GB with 16x 32 GB LRDIMMs and two processors
Memory protectionECC, Chipkill, memory mirroring, and memory rank sparing.
Drive baysUp to fourteen 3.5-inch SAS/SATA hot-swap drive bays (12 standard, two with the optional rear backplane).
Maximum internal storage Up to 84 TB with 6 TB 3.5-inch NL SATA or NL SAS HDDs, or up to 22.4 TB with 1.6 GB 3.5-inch SATA SSDs. An intermix of SAS/SATA is supported.
RAID supportRAID 0, 1, and 10 with H1110 (rear drives only), M1115, M1215, M5110, or M5210. Upgrades to RAID 5 and 50 are available for M1115 and M1215. Upgrades to RAID 5 and 50 are available for M5110 (zero-cache; 512 MB battery-backed cache; 512 MB or 1 GB flash-backed cache) and M5210 (zero-cache; 1 GB cache with no backup; 1 GB or 2 GB or 4 GB flash-backed cache). Upgrade to RAID 6 or 60 is available for M5110 and M5210 with caches.
Optical drive baysNo internal bays; use an external USB drive. See http://support.lenovo.com/en/documents/pd011281 for options.
Tape drive baysNone.
Network interfacesThree integrated Gigabit Ethernet 1000BASE-T RJ-45 ports (Intel I350-AM4); two optional 10 GbE ports on the mezzanine LOM cards.
PortsTwo USB 2.0 ports on the front. Four USB 2.0, one DB-15 video, one DB-9 serial, and four RJ-45 GbE network ports on the rear. One internal USB port for hypervisor.
CoolingCalibrated Vectored Cooling with three redundant non-hot-swap fans; each fan has two motors. Two additional non-hot-swap fans in the rear drive assembly.
Power supplyUp to two redundant hot-swap 750 W HE AC or 900 W HE AC power supplies (all AC power supplies are 80 PLUS certified).
Hot-swap partsHard disk drives, power supplies.
I/O expansion slotsUp to three slots, depending on the riser cards installed. The slots are as follows:
  • Slot 1: PCIe 3.0 x8 (x8-wired), optional PCIe 3.0 x16 (x16-wired); full-height (also supports low profile adapters with the 3U bracket), half-length
  • Slot 2: PCIe 3.0 x8 (x8-wired); low-profile, half-length (not present if an optional x16-wired slot 1 riser is used)
  • Slot 3: PCIe 3.0 x8 (x8-wired); dedicated slot for ServeRAID adapter
Systems management UEFI, Integrated Management Module II (IMM2), Predictive Failure Analysis, basic light path diagnostics, Automatic Server Restart, Systems Director and Systems Director Active Energy Manager, and ServerGuide. Optional IMM Advanced FoD Upgrade for remote presence (graphics, keyboard and mouse, and virtual media).
Security featuresPower-on password, administrator's password, and Trusted Platform Module (TPM).
VideoMatrox G200eR2 with 16 MB memory integrated into the IMM2. Maximum resolution is 1600x1200 at 75 Hz with 16 M colors.
Operating systems supported Microsoft Windows 2012 R2, 2012, and 2008 R2, Red Hat Enterprise Linux 5 and 6 (both x86 and x64), SUSE Linux Enterprise Server 11 (x86 and x64), VMware vSphere (ESXi) 5.1 and 5.5.
Limited warranty Three-year customer-replaceable unit and onsite limited warranty with 9x5/NBD.
Service and supportOptional service upgrades (country-specific) are available through ServicePac® offerings: 4-hour or 2-hour response time, 8 hours fix time, one-year or two-year warranty extension, remote technical support for Lenovo hardware and selected Lenovo and third-party (Linux) software.
DimensionsHeight: 86 mm (3.4 in.), width: 447 mm (17.6 in.), depth: 749 mm (29.5 in.)
WeightMinimum configuration: 16.4 kg (36.2 lb), maximum: 29.8 kg (65.7 lb)

The x3650 M4 BD servers are shipped with the following items:
  • Statement of Limited Warranty
  • Important Notices
  • Rack Installation Instructions
  • Documentation CD containing Installation and User's Guide
  • Rail kit (static rails, non-sliding; no cable management arm included)
  • One 2.8 m, 10A/100-250 V, C13 to IEC 320-C14 rack power cable

Standard models

The following table lists the standard models.

Table 2. Standard models

MTM*Intel Xeon processor†
(2 maximum)
Memory (RDIMMs)RAIDDrive baysDrivesOnboard NICI/O slots
(std / max)
Optical drivePower supply
(std / max)
Models announced January 2014
5466-A2x1x E5-2603 v2 4C 1.8GHz
10MB 1333MHz 80W
1x 8GB
1600MHz§
M511012x 3.5"
HS / 14
Open bay3x GbE,
2x 10 GbE
3 / 3None1x 750W HS / 2
5466-A4x1x E5-2603 v2 4C 1.8GHz
10MB 1333MHz 80W
1x 8GB
1600MHz§
M511012x 3.5"
HS / 14
Open bay3x GbE3 / 3None1x 750W HS / 2
5466-B2x1x E5-2609 v2 4C 2.5GHz
10MB 1333MHz 80W
1x 8GB
1600MHz§
M5110 512MB Flash12x 3.5"
HS / 14
Open bay3x GbE3 / 3None1x 750W HS / 2
5466-C2x1x E5-2620 v2 6C 2.1GHz
15MB 1600MHz 80W
1x 8GB
1600MHz
M5110 512MB Flash12x 3.5"
HS / 14
Open bay3x GbE,
2x 10 GbE
3 / 3None1x 750W HS / 2
5466-C4x1x E5-2620 v2 6C 2.1GHz
15MB 1600MHz 80W
1x 8GB
1600MHz
M5110 512MB Flash12x 3.5"
HS / 14
Open bay3x GbE3 / 3None1x 750W HS / 2
5466-D2x1x E5-2630L v2 6C 2.4GHz
15MB 1600MHz 60W
1x 8GB
1600MHz
M5110 512MB Flash12x 3.5"
HS / 14
Open bay3x GbE,
2x 10 GbE
3 / 3None1x 750W HS / 2
5466-F2x1x E5-2660 v2 10C 2.2GHz
25MB 1866MHz 95W
1x 8GB
1600MHz§
H1110, N211512x 3.5"
HS / 14
Open bay3x GbE,
2x 10 GbE
3 / 3None1x 900W HS / 2
5466-F4x1x E5-2660 v2 10C 2.2GHz
25MB 1866MHz 95W
1x 8GB
1600MHz§
H1110, N211512x 3.5"
HS / 14
Open bay3x GbE3 / 3None1x 900W HS / 2
5466-G2x1x E5-2695 v2 12C 2.4GHz
30MB 1866MHz 115W
1x 8GB
1600MHz§
M5110 1GB Flash12x 3.5"
HS / 14
Open bay3x GbE3 / 3None1x 900W HS / 2
* x in the Machine Type Model (MTM) represents a country-specific letter (for example, the EMEA MTM is 5466-A2G, and the US MTM is 5466-A2G). Ask a Lenovo representative for specifics.
† Processor detail: Processor quantity and model, number of cores, core speed, L3 cache, memory speed, and TDP.
§ For models A2x, A4x, and B2x, the standard DIMM is rated at 1600 MHz, but operates at up to 1333 MHz to match the processor memory speed. Conversely, for models F2x, F4x, and G2x, the processor memory speed is rated at 1866 MHz, but operates at up to 1600 MHz to match the rated speed of the installed DIMM. Actual memory speed maximums depend on several factors, as described in "Memory options".

For more information about the standard features of the server, see the "Specifications" section.

Express models

The following table lists the express models.

Table 3. Express models

MTM*Intel Xeon processor†
(2 maximum)
Memory (RDIMMs)RAIDDrive baysDrivesOnboard NICI/O slots
(std / max)
Optical drivePower supply
(std / max)
Europe, Middle East, and Africa
5466-E1x1x E5-2620 v2 6C 2.1GHz
15MB 1600MHz 80W
1x 8GB
1600MHz
M511012x 3.5"
HS / 14
Open bay3x GbE3 / 3None1x 750W HS / 2
* x in the Machine Type Model (MTM) represents a country-specific letter (for example, the EMEA MTM is 5466-A2G, and the US MTM is 5466-A2G). Ask a Lenovo representative for specifics.
† Processor detail: Processor quantity and model, number of cores, core speed, L3 cache, memory speed, and TDP.

Processor options

The x3650 M4 BD supports the processor options that are listed in the following table. The server supports up to two Intel Xeon processor E5-2600 v2 product family processors. This table shows which server models have each processor standard. If there is no corresponding where-used model for a particular processor, this processor is only available through CTO.

Table 4. Processor options

Part numberFeature codes*DescriptionStandard models
where used
00AL138A4RX / A4S6Intel Xeon Processor E5-2603 v2 4C 1.8GHz 10MB Cache 1333MHz 80WA2x, A4x
00AL139A4RY / A4S7Intel Xeon Processor E5-2609 v2 4C 2.5GHz 10MB Cache 1333MHz 80WB2x
00AL140A4RZ / A4S8Intel Xeon Processor E5-2620 v2 6C 2.1GHz 15MB Cache 1600MHz 80WC2x, C4x
00KA570A5GS / A5H2Intel Xeon Processor E5-2628L v2 8C 1.9GHz 20MB Cache 1600MHz 70W-
00AL141A4S0 / A4S9Intel Xeon Processor E5-2630 v2 6C 2.6GHz 15MB Cache 1600MHz 80W-
00AL142A4S1 / A4SEIntel Xeon Processor E5-2630L v2 6C 2.4GHz 15MB Cache 1600MHz 60WD2x
00AL143A4S2 / A4SCIntel Xeon Processor E5-2640 v2 8C 2.0GHz 20MB Cache 1600MHz 95W-
00KA569A5GR / A5H1Intel Xeon Processor E5-2648L v2 10C 1.9GHz 25MB Cache 1866MHz 70W-
00AL145A4S4 / A4SAIntel Xeon Processor E5-2650 v2 8C 2.6GHz 20MB Cache 1866MHz 95W-
00AL146A4S5 / A4SDIntel Xeon Processor E5-2650L v2 10C 1.7GHz 25MB Cache 1600MHz 70W-
00AL144A4S3 / A4SBIntel Xeon Processor E5-2660 v2 10C 2.2GHz 25MB Cache 1866MHz 95WF2x, F4x
00AL148A4TA / A4TGIntel Xeon Processor E5-2670 v2 10C 2.5GHz 25MB Cache 1866MHz 115W-
00AL149A4TB / A4THIntel Xeon Processor E5-2680 v2 10C 2.8GHz 25MB Cache 1866MHz 115W-
00AL147A4T9 / A4TFIntel Xeon Processor E5-2695 v2 12C 2.4GHz 30MB Cache 1866MHz 115WG2x
* The first feature code is for the first processor; the second feature code is for the second processor.

Memory options

Lenovo DDR3 memory is compatibility tested and tuned for optimal System x performance and throughput. Lenovo memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime. From a service and support standpoint, Lenovo memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.

The System x3650 M4 BD supports DDR3 memory. The server supports up to eight DIMMs when one processor is installed and up to 16 DIMMs when two processors are installed. Each processor has four memory channels, and there are two DIMMs per channel.

The following rules apply when selecting the memory configuration:

  • The server supports UDIMMs, RDIMMs, and LRDIMMs.
  • Mixing different types of memory (UDIMMs, RDIMMs, and LRDIMMs) is not supported.
  • Mixing 1.5 V and 1.35 V DIMMs is not supported.
  • The maximum number of ranks per one channel is eight (with the exception of Load Reduced DIMMs where more than eight ranks are supported because one quad-rank LRDIMM provides the reduced electrical load on a memory bus).
  • The maximum quantity of DIMMs that can be installed in the server depends on the number of processors, DIMM type, rank, and operating voltage, as shown in the "Max. qty supported" row in Table 5.
  • All DIMMs in the server operate at the same speed, which is determined as the lowest value of:
    • Memory speed that is supported by the specific processor.
    • Lowest of maximum operating speeds for selected memory configuration that depends on rated speed, operating voltage, and quantity of DIMMs per channel, as shown under "Maximum operating speed" section in the table.

The following memory protection technologies are supported:
  • ECC
  • Chipkill (for x4-based memory DIMMs)
  • Memory mirroring
  • Memory rank sparing

Chipkill works only in independent channel mode (the default is operational mode) and supports only x4-based memory DIMMs.

If memory mirroring is used, then DIMMs must be installed in pairs (a minimum of one pair per each processor, and a maximum of two pairs per processor), and both DIMMs in a pair must be identical in type and size.

If memory rank sparing is used, then two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need to be identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs installed.

Chipkill, memory mirroring, and memory rank sparing modes are mutually exclusive. Only one operational memory mode can be enabled on a server, and it is a system-wide setting.

The following table (Parts 1 and 2) shows the characteristics of the supported DIMMs. Tables cells that are highlighted with a gray background indicate when the combination of DIMM voltage and the number of DIMMs per channel still allows the DIMMs to operate at a rated speed.

Table 5. Maximum memory speeds (Part 1: RDIMMs)
DIMM specification
RDIMM
Rank
Single rank
Dual rank
Part numbers
00D5024 (4 GB)
00D5036 (8 GB)
00D5020 (4 GB)
00D5032 (8 GB)
00D5044 (8 GB)
46W0672 (16 GB)
00D5048 (16 GB)
Rated speed
1600 MHz
1866 MHz
1600 MHz
1866 MHz
Rated voltage
1.35 V
1.5 V
1.35 V
1.5 V
Operating voltage
1.35 V
1.5 V
1.5 V
1.35 V
1.5 V
1.5 V
Max qty supported*
16
16
16
16
16
16
Max DIMM capacity
8 GB
8 GB
8 GB
16 GB
16 GB
16 GB
Max memory capacity
128 GB
128 GB
128 GB
256 GB
256 GB
256 GB
Max. memory at rated speed
None**
128 GB
64 GB
None**
256 GB
256 GB
Maximum operating speed
1 DIMM per channel
1333 MHz
1600 MHz
1866 MHz
1333 MHz
1600 MHz
1866 MHz
2 DIMMs per channel
1333 MHz
1600 MHz
1600 MHz
1333 MHz
1600 MHz
1866 MHz
* The maximum quantity that is supported is shown for two processors installed.
** Rated speed is not supported. Memory DIMMs always operate at speeds lower than rated.

Table 5. Maximum memory speeds (Part 2: UDIMMs and LRDIMMs)
DIMM specification
UDIMM
LRDIMM
Rank
Dual rank
Quad rank
Part number
00D5016 (8 GB)
46W0761 (32 GB)
Rated speed
1600 MHz
1866 MHz
Rated voltage
1.35 V
1.5 V
Operating voltage
1.35 V
1.5 V
1.5 V
Max. qty supported*
16
16
16
Max. DIMM capacity
8 GB
8 GB
32 GB
Max. memory capacity
128 GB
128 GB
512 GB
Max. memory at rated speed
None**
128 GB
256 GB
Maximum operating speed
1 DIMM per channel
1333 MHz
1600 MHz
1866 MHz
2 DIMMs per channel
1333 MHz
1600 MHz
1600 MHz
* Maximum quantity that is supported is shown for two processors installed.
** Rated speed is not supported. Memory DIMMs always operate at speeds lower than rated.

The following table lists the memory options that are available for the x3650 M4 BD server.

Table 6. Memory options
Part numberFeature codeDescriptionMaximum
supported
Standard models
where used
UDIMMs
00D5016A3QC8GB (1x8GB, 2Rx8, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP UDIMM16 (8 per CPU)-
RDIMMs - 1600 MHz
00D5024A3QE4GB (1x4GB, 1Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM16 (8 per CPU)-
00D5036A3QH8GB (1x8GB, 1Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM16 (8 per CPU)A2x, A4x, B2x, C2x, C4x, D2x, F2x, F4x, G2x
00D5044A3QK8GB (1x8GB, 2Rx8, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM16 (8 per CPU)-
46W0672A3QM16GB (1x16GB, 2Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM16 (8 per CPU)-
RDIMMs - 1866 MHz
00D5020A3QD4GB (1x4GB, 1Rx4, 1.5V) PC3-14900 CL13 ECC DDR3 1866MHz LP RDIMM16 (8 per CPU)-
00D5032A3QG8GB (1x8GB, 1Rx4, 1.5V) PC3-14900 CL13 ECC DDR3 1866MHz LP RDIMM16 (8 per CPU)-
00D5048A3QL16GB (1x16GB, 2Rx4, 1.5V) PC3-14900 CL13 ECC DDR3 1866MHz LP RDIMM16 (8 per CPU)-
LRDIMMs
46W0761A47K32GB (1x32GB, 4Rx4, 1.5V) PC3-14900 CL13 ECC DDR3 1866MHz LP LRDIMM16 (8 per CPU)-

Internal storage

The x3650 M4 BD server supports the following internal storage configurations:

  • Twelve 3.5-inch SAS/SATA hot-swap drive bays
  • Fourteen 3.5-inch SAS/SATA hot-swap drive bays

Standard models ship with twelve 3.5-inch SAS/SATA hot-swap drive bays, and they can also be upgraded to fourteen 3.5-inch hot-swap drive bay models with the optional rear drive backplane (rear cage assembly comes standard with the server). The following table shows the internal storage expansion options that are available.

Table 7. Internal storage expansion options
Part numberFeature codeDescriptionMaximum supportedStandard models where used
00FK886A4RTRear Backplane, 2x3.5" HDD Extension To Front Array (14-HDD Array)1-
00AL184A4RURear Backplane, 2x3.5" HDD Separate Array1-

Option 00FK886 is used to upgrade standard (see Table 2) or custom (CTO or special bid) models with twelve 3.5-inch hot-swap drive bays to fourteen 3.5-inch hot-swap drive bays; all 14 drives are connected to the same storage controller (M1115, M5110, M5210, or N2115).

Option 00AL184 is used to upgrade standard (see Table 2) or custom (CTO or special bid) models with twelve 3.5-inch hot-swap drive bays to fourteen 3.5-inch hot-swap drive bays; two rear drives are connected to the first RAID controller (H1110), and 12 drives on the front of the server are connected to a separate RAID controller (M1115, M5110, M5210, or N2115). In addition, x3650 M4 BD supports booting from the rear drives in the configurations with the H1110 controller.

Controllers for internal storage

The following table (Parts 1 and 2) lists the storage controllers and the additional options that are used for the internal storage of the x3650 M4 BD server.

Table 8. RAID controllers and HBAs for internal storage (Part 1: 6 Gbps SAS)

Part
number
Feature
code
DescriptionMaximum supportedStandard
models
where used
6 Gb SAS/SATA controllers
81Y4492A1XLServeRAID H1110 SAS/SATA Controller1F2x, F4x
81Y4448A1MZServeRAID M1115 SAS/SATA Controller1-
81Y4481A347ServeRAID M5110 SAS/SATA Controller1A2x, A4x, B2x, C2x, C4x, D2x, G2x
46C8988A3MWN2115 SAS/SATA HBA for System x1 F2x, F4x
Hardware upgrades for the M5110 and M5110e
81Y4508A22EServeRAID M5100 Series Battery Kit1*-
81Y4484A1J3ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade1-
81Y4487A1J4ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade1B2x, C2x, C4x, D2x
81Y4559A1WYServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade1G2x
47C8670A4G6ServeRAID M5100 Series 2GB Flash/RAID 5 Upgrade1-
Feature on Demand upgrades for the M1115, M5110, and M5110e
81Y4542A1X1ServeRAID M1100 Series Zero Cache/RAID 5 Upgrade 1-
81Y4544A1X2ServeRAID M5100 Series Zero Cache/RAID 5 Upgrade1-
90Y4318A2MDServeRAID M5100 Series SSD Caching Enabler1-
90Y4273A2MCServeRAID M5100 Series SSD Performance Key1-
81Y4546A1X3ServeRAID M5100 Series RAID 6 Upgrade1†-
* The ServeRAID M5100 Series Battery Kit (81Y4508) is supported only with ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade (81Y4484).
† The ServeRAID M5100 Series RAID 6 Upgrade (81Y4546) requires 512 MB or 1 GB cache upgrades.

Table 8. RAID controllers and HBAs for internal storage (Part 2: 12 Gbps SAS)
Part
number
Feature
code
DescriptionMaximum
supported
Standard
models
where used
12 Gb SAS/SATA controllers
46C9110A3YZServeRAID M5210 SAS/SATA Controller1†-
46C9114A45WServeRAID M1215 SAS/SATA Controller1-
47C8675A3YYN2215 SAS/SATA HBA 1†-
Hardware upgrades for the M5210
47C8656A3Z0ServeRAID M5200 Series 1GB Cache/RAID 5 Upgrade1-
47C8660A3Z1ServeRAID M5200 Series 1GB Flash/RAID 5 Upgrade1-
47C8664A3Z2ServeRAID M5200 Series 2GB Flash/RAID 5 Upgrade1-
47C8668A3Z3ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade1-
Feature on Demand upgrades for the M5210
47C8708A3Z6ServeRAID M5200 Series Zero Cache/RAID 5 Upgrade1-
47C8706A3Z5ServeRAID M5200 Series RAID 6 Upgrade1*-
47C8710A3Z7ServeRAID M5200 Series Performance Accelerator1*-
47C8712A3Z8ServeRAID M5200 Series SSD Caching Enabler1*-
Feature on Demand upgrades for the M1215
00AE930A5H5ServeRAID M1200 Zero Cache/RAID 5 Upgrade FOD1-
* Requires cache memory upgrade (47C8656, 47C8660, or 47C8664).
† The use of either the ServeRAID M5210 or N2215 SAS HBA requires an additional cable be ordered: Cable, IPASS, semi-HD, 820mm for 12Gb cards, part number 00KF334, feature A4TK

The internal storage controller other than H1110 is installed into a dedicated PCIe slot (slot 3). In the configurations with the H1110, the H1110 is installed in PCIe slot 2, and the second storage controller is installed in slot 3.

The following table lists the drive types and internal drive bay configurations that are supported by the storage controllers (SAS HDDs include both SAS and NL SAS HDDs, and SATA HDDs include both SATA and NL SATA HDDs).

Table 9. Drive types and internal drive bay configurations that are supported by the RAID controllers
RAID controller or HBADrive type12x 3.5-inch
hot-swap (front)
2x 3.5-inch
hot-swap (rear)
ServeRAID H1110SAS HDDNo supportYes
SATA HDDNo supportYes
SATA SSDNo supportYes
ServeRAID M1115
ServeRAID M1215
SAS HDDYesYes*
SATA HDDYesYes*
SATA SSDYesYes*
ServeRAID M5110
ServeRAID M5210
SAS HDDYesYes*
SATA HDDYesYes*
SATA SSDYesYes*
N2115SAS HDDYesYes*
SATA HDDYesYes*
SATA SSDYesYes*
* The rear drives are connected to the same RAID controller or HBA as the front drives. A single RAID controller or HBA is used for both front and rear drives.

The ServeRAID H1110 adapter has the following specifications:
  • Four internal 6 Gbps SAS/SATA ports
  • Up to 6 Gbps throughput per port
  • One x4 mini-SAS internal connector (SFF-8087)
  • Based on the LSI SAS2004 6 Gbps RAID on Chip (ROC) controller
  • PCIe 2.0 x4 host interface
  • Supports RAID 0, 1, 1E, and 10
  • Connects to up to four SAS or SATA drives (SAS expanders are not supported.)

The ServeRAID M1115 SAS/SATA Controller has the following specifications:
  • Eight internal 6 Gbps SAS/SATA ports
  • Up to 6 Gbps throughput per port
  • Two x4 mini-SAS internal connectors (SFF-8087)
  • Supports connections to SAS/SATA drives and SAS Expanders
  • Supports RAID 0, 1, and 10
  • Supports RAID 5 and 50 with optional M1100 Series RAID 5 upgrades
  • PCIe 2.0 x8 host interface
  • Based on the LSI SAS2008 6 Gbps ROC controller

The ServeRAID M5110 SAS/SATA Controller has the following specifications:
  • Eight internal 6 Gbps SAS/SATA ports
  • Up to 6 Gbps throughput per port
  • Two x4 mini-SAS internal connectors (SFF-8087)
  • Supports connections to SAS/SATA drives and SAS Expanders
  • Supports RAID 0, 1, and 10
  • Supports RAID 5 and 50 with optional M5100 Series RAID 5 upgrades
  • Supports RAID 6 and 60 with the optional M5100 Series RAID 6 upgrade
  • Supports 512 MB battery-backed cache or 512 MB or 1 GB flash-backed cache
  • Support for SSD performance optimization with the optional M5100 Series Performance Accelerator and SSD Caching Enabler
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS2208 6 Gbps ROC controller

The N2115 SAS/SATA HBA has the following specifications:
  • Eight internal 6 Gbps SAS/SATA ports
  • Up to 6 Gbps throughput per port
  • Two x4 mini-SAS internal connectors (SFF-8087)
  • Supports connections to SAS/SATA HDDs and SATA SSDs
  • Optimized for SSD performance
  • No RAID support
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS2308 6 Gbps controller

The ServeRAID M5210 SAS/SATA Controller has the following specifications:
  • Eight internal 12 Gbps SAS/SATA ports
  • Up to 12 Gbps throughput per port
  • Two x4 HD mini-SAS internal connectors (SFF-8643)
  • Supports connections to SAS/SATA drives and SAS Expanders
  • Supports RAID 0, 1, and 10
  • Supports RAID 5 and 50 with optional M5200 Series RAID 5 upgrades
  • Supports RAID 6 and 60 with the optional M5200 Series RAID 6 upgrade
  • Supports 1 GB non-backed cache or 1 GB or 2 GB flash-backed cache
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS3108 12 Gbps ROC controller

The N2215 SAS/SATA HBA has the following specifications:
  • Eight internal 12 Gbps SAS/SATA ports
  • Up to 12 Gbps throughput per port
  • Two x4 HD mini-SAS internal connectors (SFF-8643)
  • Supports connections to SAS/SATA HDDs and SATA SSDs
  • Optimized for SSD performance
  • No RAID support
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS3008 12 Gbps controller

The ServeRAID M1215 SAS/SATA Controller has the following specifications:
  • Eight internal 12 Gbps SAS/SATA ports
  • Up to 12 Gbps throughput per port
  • Two internal mini-SAS HD connectors (SFF-8643)
  • LSI SAS3008 12 Gbps RAID on Chip (ROC) controller
  • Support for RAID levels 0, 1, and 10 standard; support for RAID 5, 50 with optional FoD upgrade
  • Zero Controller Cache, no battery/flash backup
  • Optional support for self-encrypting drives (SEDs) with MegaRAID SafeStore (with RAID 5 upgrade)
  • Fixed stripe size of 64 KB

For more information, see the list of Lenovo Press Product Guides in the RAID adapters category:
http://lenovopress.com/systemx/raid

Internal drive options

The following table lists the hard disk drive options for the internal disk storage of the x3650 M4 BD server.

Table 10. Disk drive options for internal disk storage

Part numberFeature codeDescriptionMaximum supported
3.5" SAS Hot-Swap HDDs
49Y6092A3DV300GB 15K 6Gbps SAS 3.5" G2HS HDD14
49Y6097A3DW450GB 15K 6Gbps SAS 3.5" G2HS HDD14
49Y6102A3DX600GB 15K 6Gbps SAS 3.5" G2HS HDD14
3.5" NL SAS Hot-Swap HDDs
90Y8567A26M1TB 7.2K 6Gbps NL SAS 3.5" G2HS HDD14
90Y8572A2U02TB 7.2K 6Gbps NL SAS 3.5" G2HS HDD14
90Y8577A2R23TB 7.2K 6Gbps NL SAS 3.5" G2HS HDD14
49Y6210A4AF4TB 7.2K 6Gbps NL SAS 3.5" G2HS HDD14
00ML203AS762TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e HDD14
00ML208AS774TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e HDD14
00ML213AS786TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e HDD14
3.5" NL SAS Hot-Swap self-encrypting drives (SEDs)
00ML218AS792TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e SED14
00ML223AS7A4TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e SED14
00ML228AS7B6TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e SED14
3.5" NL SATA Hot-Swap HDDs
81Y9786A22Y500GB 7.2K 6Gbps NL SATA 3.5" G2HS HDD14
81Y9790A22P1TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD14
81Y9794A22T2TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD14
81Y9798A22S3TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD14
49Y6002A3W94TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD14
3.5" NL SATA Hot-Swap 512e HDDs
00FN113A5VD2TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD14
00FN128A5VF3TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD14
00FN143A5VH4TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD14
00FN158A5VK5TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD14
00FN173A5VM6TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD14
3.5" SATA Hot-Swap SSDs - Enterprise Value
00AJ435A57F120GB SATA 3.5" MLC HS Enterprise Value SSD14
00AJ440A57G240GB SATA 3.5" MLC HS Enterprise Value SSD14
00AJ445A57H480GB SATA 3.5" MLC HS Enterprise Value SSD14
00AJ450A57J800GB SATA 3.5" MLC HS Enterprise Value SSD14
00FN288A5U7S3500 1.6TB SATA 3.5" MLC HS Enterprise Value SSD
3.5" SATA Hot-Swap SSDs - Entry
00FN352AS0K240GB SATA 3.5" MLC HS Entry SSD14
00FN357AS0L480GB SATA 3.5" MLC HS Entry SSD14
00FN362AS0M960GB SATA 3.5" MLC HS Entry SSD14

Internal backup units

The x3650 M4 BD server does not support internal tape drive options or other internal backup units. However, it can be attached to the external tape drives by using USB or SAS connectivity.

Optical drives

No internal bays; use an external USB drive. See http://support.lenovo.com/en/documents/pd011281 for options.

I/O expansion options

The x3650 M4 BD server supports up to three PCIe slots with different riser cards installed into two riser sockets on the system board (one riser socket supports the installation of one riser card).

The slot form factors with 1U risers (models with the rear HDD cage assembly) are as follows:

  • Slot 1: PCIe 3.0 x8 (x8-wired), optional PCIe 3.0 x16 (x16-wired); full-height (also supports low profile adapters with the 3U bracket), half-length
  • Slot 2: PCIe 3.0 x8 (x8-wired); low-profile, half-length (not present if an optional x16-wired slot 1 riser is used)
  • Slot 3: PCIe 3.0 x8 (x8-wired); dedicated slot for ServeRAID adapter

The following table lists the I/O riser card options.

Table 11. I/O riser card options
Part numberFeature codeDescriptionMaximum
supported
Standard models
where used
1U Riser 1 option (supplies slots 1 and 2)
00AL182A4T81U Riser Card, One PCIe x16 slot1-
00AL181A4T61U Riser Card, Two PCIe x8 slots1A2x, A4x, B2x, C2x, C4x, D2x, F2x, F4x, G2x
1U Riser 2 option (supplies slot 3)
00AL183A4T71U Riser Card, One PCIe x8 slot (For Slotless RAID only)1A2x, A4x, B2x, C2x, C4x, D2x, F2x, F4x, G2x

Network adapters

The x3650 M4 BD supports three integrated Gigabit Ethernet ports. Integrated NIC has the following features:

  • An Intel I350-AM4 chip
  • Three Gigabit Ethernet ports
  • NIC Teaming (load balancing and failover)
  • Ethernet features:
    • 1 Gb Ethernet IEEE 802.3, 802.3u, and 802.3ab PHY specifications compliant
    • Integrated PHY for 10/100/1000 Mbps for multispeed, full, and half-duplex auto-negotiation
    • IEEE 802.3x and 802.3z compliant flow control support with software-controllable Rx thresholds and Tx pause frames
    • Automatic cross-over detection function (MDI/MDI-X)
    • IEEE 1588 protocol and 802.1AS implementation
    • IEEE802.3az - Energy Efficient Ethernet (EEE)
    • Full wake-up support
      • Advanced Power Management (APM) support
      • Advanced Configuration and Power Interface (ACPI) specification v2.0c
      • Magic packet wake-up enable
  • I/O Virtualization Features:
    • Eight transmit (Tx) and receive (Rx) queue pairs per port
    • Flexible port partitioning: 32 virtual functions (VF) with four ports or 16 VFs with two ports
    • Rx/Tx round-robin scheduling
    • Traffic isolation and traffic steering
    • Virtual machine (VM) to VM packet forwarding (packet loopback)
    • MAC and VLAN anti-spoofing
    • Malicious driver detection
    • Storm control
    • Per-pool statistics, off loads, and jumbo support
    • Independent Function Level Reset (FLR) for physical and virtual functions
    • IEEE 802.1q Virtual Local Area Network (VLAN) support with VLAN tag insertion, stripping, and packet filtering for up to 4096 VLAN tags
    • IEEE 802.1q advanced packet filtering
    • Mirroring rules
    • Support for simple VEPA
    • VF promiscuous modes
  • Stateless offload and performance features:
    • TCP/UDP, IPv4 checksum offloads (Rx/ Tx/Large-send); extended Tx descriptors
    • IPv6 support for IP/TCP and IP/UDP receive checksum offload
    • Tx TCP segmentation offload (IPv4 and IPv6)
    • Transmit Segmentation Offloading (TSO)
    • Interrupt throttling control
    • Legacy and Message Signal Interrupt (MSI)
    • Message Signal Interrupt Extension (MSI-X)
    • Receive Side Scaling (RSS) for Windows
    • Scalable I/O for Linux environments (IPv4, IPv6, and TCP/UDP)
    • Support for packets up to 9.5 KB (jumbo frames)

The following table lists additional supported network adapters.

Table 12. Network adapters
Part numberFeature codeDescriptionMaximum supported
40 Gb Ethernet
00D9550A3PNMellanox ConnectX-3 40GbE / FDR IB VPI Adapter for System x2
10 Gb Ethernet
44T1360A4YQBroadcom NetXtreme 2x10 GbE SFP+ Mezz Adapter for System x2**
44T1370A5GZBroadcom NetXtreme 2x10GbE BaseT Adapter for System x2
94Y5180A4Z6Broadcom NetXtreme Dual Port 10GbE SFP+ Adapter for System x2**
49Y7910A18YBroadcom NetXtreme II Dual Port 10GBaseT Adapter for System x2
00D8540A4XHEmulex Dual Port 10GbE SFP+ VFA IIIr for System x2**
95Y3760A2U2Emulex VFA III/IIIr FCoE/iSCSI License for System x (FoD)
(Features on Demand upgrade for 00D8540)
2
00JY830A5UUEmulex VFA5 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW for System x2
NoneAS3MEmulex VFA5 2x10 GbE SFP+ Integrated Adapter for System x2
00JY820A5UTEmulex VFA5 2x10 GbE SFP+ PCIe Adapter for System x2
00JY824A5UVEmulex VFA5 FCoE/iSCSI SW for PCIe Adapter for System x (FoD)
(Features on Demand upgrade for 00JY820 and feature AS3M)
2
49Y7960A2ECIntel X520 Dual Port 10GbE SFP+ Adapter for System x2**
00AL653A4X7Intel X520 Dual Port 10GbE SFP+ Embedded Adapter with Interposer*1**
49Y7970A2EDIntel X540-T2 Dual Port 10GBaseT Adapter for System x2
81Y3520AS73Intel X710 2x10GbE SFP+ Adapter for System x2
00D9690A3PMMellanox ConnectX-3 10 GbE Adapter for System x2
42C18005751QLogic 10Gb CNA for System x2**
90Y4600A3MRQLogic 8200 Dual Port 10GbE SFP+ VFA for System x2**
00Y5624A3MTQLogic 8200 VFA FCoE/iSCSI License for System x (FoD)
(Features on Demand upgrade for 00Y5624, one per adapter)
2
47C9952A47HSolarflare SFN5162F 2x10GbE SFP+ Performant Adapter for System x2**
47C9960A47JSolarflare SFN6122F 2x10GbE SFP+ Onload Adapter for System x2**
Gigabit Ethernet
42C17802995Broadcom NetXtreme 2xGbE BaseT Adapter for System x2
90Y9370A2V4Broadcom NetXtreme I Dual Port GbE Adapter for System x2
90Y9352A2V3Broadcom NetXtreme I Quad Port GbE Adapter for System x2
49Y42305767Intel Ethernet Dual Port Server Adapter I340-T2 for System x2
49Y42405768Intel Ethernet Quad Port Server Adapter I340-T4 for System x2
00AG500A56KIntel I350-F1 1xGbE Fiber Adapter for System x2
00AG510A56LIntel I350-T2 2xGbE BaseT Adapter for System x2
00AG520A56MIntel I350-T4 4xGbE BaseT Adapter for System x2
* The embedded adapter is installed in a regular PCIe slot (slot 1) through an interposer that is included with the adapter.
** Require SFP+ optical transceivers or DAC cables that must be purchased separately.

For more information, see the list of Lenovo Press Product Guides in the Ethernet and IB adapters category:
http://lenovopress.com/systemx/networkadapters


Storage host bus adapters

The following table lists the storage HBAs that are supported by the x3650 M4 BD server.

Table 13. Storage adapters
Part numberFeature codeDescriptionMaximum supported
Fibre Channel - 16 Gb
81Y1668A2XUBrocade 16Gb FC Single-port HBA for System x2
81Y1675A2XVBrocade 16Gb FC Dual-port HBA for System x2
81Y1662A2W6Emulex 16Gb FC Dual-port HBA for System x2
81Y1655A2W5Emulex 16Gb FC Single-port HBA for System x2
00Y3337A3KWQLogic 16Gb FC Single-port HBA for System x2
00Y3341A3KXQLogic 16Gb FC Dual-port HBA for System x2
Fibre Channel - 8 Gb
46M60503591Brocade 8Gb FC Dual-port HBA for System x2
46M60493589Brocade 8Gb FC Single-port HBA for System x2
42D04943581Emulex 8Gb FC Dual-port HBA for System x2
SAS
46C9010A3MVN2125 SAS/SATA HBA for System x2
00AE912A5M0N2225 SAS/SATA HBA for System x2
00AE916A5M1N2226 SAS/SATA HBA for System x2

For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category:
http://lenovopress.com/systemx/hba

PCIe SSD adapters

The x3650 M4 BD server supports the High IOPS SSD adapters that are listed in the following table.

Table 14. SSD adapters

Part numberFeature codeDescriptionMaximum supported
46C9078A3J3365GB High IOPS MLC Mono Adapter1
46C9081A3J4785GB High IOPS MLC Mono Adapter1
90Y4377A3DY1.2TB High IOPS MLC Mono Adapter1
00AE861A4WTFlash Adapter F825 Enterprise Value for System x2
00AE864A4WSFlash Adapter F1650 Enterprise Value for System x2
00AE867A4WRFlash Adapter F3200 Enterprise Value for System x1
00AE995ARYP1000GB Enterprise io3 Flash Adapter for System x2
00AE998ARYQ1300GB Enterprise io3 Flash Adapter for System x2
00JY001ARYR2600GB Enterprise io3 Flash Adapter for System x2
00AE983ARYK1250GB Enterprise Value io3 Flash Adapter for System x2
00AE986ARYL1600GB Enterprise Value io3 Flash Adapter for System x2
00AE989ARYM3200GB Enterprise Value io3 Flash Adapter for System x2

GPU adapters

The x3650 M4 BD server supports graphics processing units (GPUs) if the riser card 00AL182 (FC A4T8) is installed. The following table lists the supported GPUs.

Table 15. GPU adapters

Part numberFeature codeDescriptionMaximum supported
None*A3WHNVIDIA Quadro K6001
* This adapter can be ordered only through CTO or special bid.

Power supplies

The server supports up to two redundant hot-swap 750 W AC or 900 W AC high efficient power supplies that are 80 PLUS certified. Standard models come with one 750 W AC or 900 W AC hot-swap power supply.

The following table lists the power supply options. An AC hot-swap power supply option ships standard with one 2.8m, 10A/100-250V, C13 to IEC 320-C14 rack power cable.

Table 16. Power supplies

Part numberFeature codeDescriptionMaximum supportedStandard models where used
00AL742A4RVSystem x 750W High Efficiency Platinum AC Power Supply2A2x, A4x, B2x, C2x, C4x, D2x
00AL743A4RWSystem x 900W High Efficiency Platinum AC Power Supply2F2x, F4x, G2x

Important: 95 W and 115 W processors require 900 W power supplies.

Integrated virtualization

The x3650 M4 BD server supports VMware ESXi installed on a USB memory key. The key is installed in a USB socket inside the server. The following table lists the virtualization options.

Table 17. Virtualization options

Part numberFeature codeDescriptionMaximum supported
41Y8298A2G0Blank USB Memory Key for VMware ESXi Downloads1
41Y8385A584USB Memory Key for VMware ESXi 5.51

Remote management

The server contains Integrated Management Module II (IMM2), which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. Optionally, the IMM2 also provides a virtual presence capability for remote server management capabilities.

The IMM2 provides remote server management through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3
  • Common Information Model (CIM)
  • Web browser

The optional Integrated Management Module Advanced Upgrade is required to enable the remote presence and blue-screen capture features. The remote presence feature provides the following functions:
  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
  • Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive

The blue-screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating system hang condition. A system administrator can use the blue-screen capture to assist in determining the cause of the hang condition. The following table lists the remote management option.

Table 18. Remote management option
Part numberFeature codeDescriptionMaximum supported
90Y3901A1MLIntegrated Management Module Advanced Upgrade1

Light path diagnostics panel

The light path diagnostics panel allows systems engineers and administrators to easily and quickly diagnose hardware problems on the System x servers. If a failure occurs, a light is illuminated on the front panel of the server (level 1 light path) to alert the systems administrator that there is a problem. This light directs the engineer or administrator directly to the failed component, which also has an illuminated LED near it (light path level 3), for example, the DIMM error LED on the system board.

x3650 M4 BD offers basic light path diagnostics, as shown in the following figure.

Basic (level 1) light path
Figure 5. Basic (level 1) light path

Supported operating systems

The server supports the following operating systems:

  • Microsoft Windows Server 2008 R2
  • Microsoft Windows Server 2012
  • Microsoft Windows Server 2012 R2
  • Red Hat Enterprise Linux 5 Server Edition
  • Red Hat Enterprise Linux 5 Server with Xen x64 Edition
  • Red Hat Enterprise Linux 5 Server x64 Edition
  • Red Hat Enterprise Linux 6 Server Edition
  • Red Hat Enterprise Linux 6 Server x64 Edition
  • Red Hat Enterprise Linux 7
  • SUSE LINUX Enterprise Server 11 for AMD64/EM64T
  • SUSE LINUX Enterprise Server 11 for x86
  • SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
  • SUSE Linux Enterprise Server 12
  • SUSE Linux Enterprise Server 12 with XEN
  • VMware vSphere 5.1 (ESXi)
  • VMware vSphere 5.5 (ESXi)

For the latest information about the specific versions and service levels that are supported and any other prerequisites, see the ServerProven® website:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

Physical and electrical specifications

Dimensions and weight:

  • Height: 86 mm (3.4 in.)
  • Width: 447 mm (17.6 in.)
  • Depth: 749 mm (29.5 in.)
  • Weight:
    • Minimum configuration: 16.4 kg (36.2 lb).
    • Maximum configuration: 29.8 kg (65.6 lb).

Supported environment:
  • Air temperature
    • Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 to 950 m (3,117 ft).
    • Server on: 5 °C to 28 °C (41 °F to 82.4 °F); altitude: 950 m (3,117 ft) to 3,050 m (10,000 ft); de-rated maximum air temperature 1 °C per 175 m.
    • Server off: 5 °C to 45 °C (41 °F to 113 °F).
    • Shipment (non-operating): -40 °C to 60 °C (-40 °F to 140 °F).
  • Humidity:
    • Server on: 8% - 85%, maximum dew point 24 °C (75 °F), maximum rate of change 5 °C/hr.
    • Server off: 8% - 85%, maximum dew point 27 °C (80.6 °F).
    • Shipment: 5% - 100%, maximum dew point 29 °C (84.2 °F).
  • Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
    • Supports cloud like workload with no performance degradation acceptable (Turbo-Off).
    • Under no circumstance can any combination of worst case workload and configuration result in system shutdown or design exposure at 40 °C.
    • The worst-case workload (like Linpack, Turbo-On) might have performance degradation.
  • Electrical
    • Models with 900 W power supplies:
      • 100 to 127 (nominal) V AC; 50 Hz or 60 Hz; 10 A
      • 200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 5 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.1 kVA
        • Maximum configuration: 0.9 kVA
    • Models with 750 W hot-swap power supplies:
      • 100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 8.9 A
      • 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 4.5 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.1 kVA
        • Maximum configuration: 0.75 kVA
  • BTU output
    • Minimum configuration: 333 Btu/hr (98 watts)
    • Maximum configuration: 3074 Btu/hr (900 watts)
  • Noise level
    • 6.6 bels (operating)
    • 6.6 bels (idle)

Warranty options

The x3650 M4 BD has a three-year warranty with 24x7 standard call center support and 9x5 Next Business Day onsite coverage. Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For more information about Lenovo warranty service upgrade offerings that are available in your country, visit the Lenovo Services website:

https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do

The following table explains warranty service definitions in more detail.

Table 19. Warranty service definitions

TermDescription
On-site serviceA service technician will arrive at the client’s location for equipment service.
24x7x2 hourA service technician is scheduled to arrive at the client’s location within two hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays.
24x7x4 hourA service technician is scheduled to arrive at the client’s location within four hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays.
9x5x4 hourA service technician is scheduled to arrive at the client’s location within four business hours after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday-Friday, excluding Lenovo holidays. For example, if a customer reports an incident at 3:00 pm on Friday, the technician will arrive by 10:00 am the following Monday.
9x5 next business dayA service technician is scheduled to arrive at the client’s location on the business day after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday - Friday, excluding Lenovo holidays. Calls received after 4:00 pm local time require an extra business day for service dispatch. Next business day service is not guaranteed.
Committed RepairProblems receive priority handling so that repairs are completed within the committed time of 6, 8, or 24 hours. Lenovo provides service 24 hours/day, every day, including Lenovo holidays.

The following Lenovo warranty service upgrades are available:
  • Warranty and maintenance service upgrades:
    • Three, four, or five years of 9x5 or 24x7 service coverage
    • Onsite response from next business day to 2 or 4 hours
    • Committed repair service
    • Warranty extension of up to 5 years
    • Post warranty extensions
  • Committed Repair Service

    Committed Repair Services enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.

    • Priority handling to meet defined time frames to restore the failing machine to good working condition
    • Committed repair service levels are measured within the following coverage hours:
      • 24x7x6: Service performed 24 hours per day, 7 days per week, within 6 hours
      • 24x7x8: Service performed 24 hours per day, 7 days per week, within 8 hours
      • 24x7x24: Service performed 24 hours per day, 7 days per week, within 24 hours
  • Hard Drive Retention

    Lenovo’s Hard Drive Retention service is a multi-drive hard drive retention offering that ensures your data is always under your control, regardless of the number of hard drives that are installed in your Lenovo server. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions.

  • Microcode Support

    Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by country and can be bundled with other warranty upgrades and extensions.

  • Remote Technical Support Services (RTS)

    RTS provides comprehensive technical call center support for covered servers, storage, operating systems, and applications. Providing a single source for support of hardware and software issues, RTS can reduce problem resolution time, decreasing the cost to address technical problems and increasing uptime. Offerings are available for Windows, Linux, IBM Systems Director, VMware, Microsoft business applications, and Lenovo System x storage devices, and IBM OEM storage devices.


Regulatory compliance

The server conforms to the following regulations:

  • Energy Star 2.0
  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 4, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • Australia/New Zealand AS/NZS CISPR 22, Class A
  • IEC 60950-1(CB Certificate and CB Test Report)
  • China CCC (GB4943), GB9254 Class A, GB17625.1
  • Taiwan BSMI CNS13438, Class A; CNS14336-1
  • Korea KN22, Class A; KN24
  • Russia, Byelorussia, and Kazakhstan, TR CU 020/2011 and TR CU 004/2011
  • CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
  • CISPR 22, Class A
  • TUV-GS (EN60950-1/IEC60950-1, EK1-ITB2000)

External disk storage expansion

The x3650 M4 BD supports attachments to the external storage expansion enclosures, by using the ServeRAID M5120 or M5225 SAS/SATA Controllers. The x3650 M4 BD server can also be attached to supported external storage systems by using the supported HBAs listed in Table 13.

The following table provides the ordering part numbers for the ServeRAID M5120 or M5225 SAS/SATA Controllers.

Table 20. Ordering part numbers and feature codes

Part numberFeature codeDescriptionMaximum supported
Adapters
81Y4478A1WXServeRAID M5120 SAS/SATA Controller for System x2
00AE938A5NDServeRAID M5225-2GB SAS/SATA Controller for System x2
Upgrades for the M5120
81Y4484A1J3ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade for System x2
81Y4487A1J4ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade for System x2
81Y4559A1WYServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade for System x2
81Y4508A22EServeRAID M5100 Series Battery Kit for System x2
81Y4546A1X3ServeRAID M5100 Series RAID 6 Upgrade for System x1*
90Y4273A2MCServeRAID M5100 Series SSD Performance Accelerator for System x1*
90Y4318A2MDServeRAID M5100 Series SSD Caching Enabler for System x1*
* One M5100 Series FoD software license is required per server.

The ServeRAID M5120 SAS/SATA Controller has the following specifications:
  • Eight external 6 Gbps SAS/SATA ports
  • Up to 6 Gbps throughput per port
  • Two external x4 mini-SAS connectors (SFF-8088)
  • Supports RAID 0, 1, and 10
  • Supports RAID 5 and 50 with optional M5100 Series RAID 5 upgrades
  • Supports RAID 6 and 60 with the optional M5100 Series RAID 6 upgrade
  • Supports 512 MB battery-backed cache or 512 MB or 1 GB flash-backed cache (cache)
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS2208 6 Gbps ROC controller
  • Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures

Cache upgrade required: The ServeRAID M5120 SAS/SATA Controller ships standard without a cache. One of the available cache upgrades (81Y4484, 81Y4487, or 81Y4559) is required for the M5120 adapter operations, and it must be purchased together with the controller.

For more information, see the Lenovo Press Product Guide ServeRAID M5120 SAS/SATA Controller for System x, TIPS0858:
http://lenovopress.com/tips0858

The ServeRAID M5225 SAS/SATA Controller has the following specifications:
  • Eight external 12 Gbps SAS/SATA ports
  • Supports 12, 6, and 3 Gbps SAS and 6 and 3 Gbps SATA data transfer rates
  • Two external x4 mini-SAS HD connectors (SFF-8644)
  • Supports 2 GB flash-backed cache (standard)
  • Supports RAID levels 0, 1, 5, 10, and 50 (standard)
  • Supports RAID 6 and 60 with the optional M5200 Series RAID 6 Upgrade
  • Supports optional M5200 Series Performance Accelerator and SSD Caching upgrades
  • PCIe x8 Gen 3 host interface
  • Based on the LSI SAS3108 12 Gbps ROC controller
  • Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures

For more information, see the Lenovo Press Product Guide ServeRAID M5225-2GB SAS/SATA Controller at:
http://lenovopress.com/tips1258

The controllers supports connectivity to the external expansion enclosures that are listed in the following table. Up to nine expansion enclosures can be daisy-chained per one adapter port. For better performance, distribute expansion enclosures evenly across both adapter ports.

Table 21. External expansion enclosures
Part numberDescriptionMaximum quantity supported per one M5225
70F0 / 70F1Lenovo ThinkServer SA1208
610012XEXP2512 Storage Enclosure17
610024XEXP2524 Storage Enclosure9

Lenovo ThinkServer SA120 support

For details about supported drives and cables for the Lenovo ThinkServer SA120, see the Lenovo Press Product Guide:
http://lenovopress.com/tips1234

EXP2512 and EXP2524 support

The external SAS cables listed in the following table support connectivity between external expansion enclosures and the controller.

Table 22. External SAS cables for external storage expansion enclosures
Part numberDescriptionMaximum quantity supported per one enclosure
ServeRAID M5120 - Server to Expansion enclosure connectivity (Mini-SAS x4 to Mini-SAS x4)
39R65313 m SAS Cable1
39R65291 m SAS Cable1
ServeRAID M5225 - Server to Expansion enclosure connectivity (Mini-SAS HD x4 to Mini-SAS x4)
00MJ1620.6m SAS Cable (mSAS HD to mSAS)1
00MJ1631.5m SAS Cable (mSAS HD to mSAS)1
00MJ1663m SAS Cable (mSAS HD to mSAS)1
Expansion enclosure to Expansion enclosure connectivity (Mini-SAS x4 to Mini-SAS x4)
39R65291 m SAS Cable1
39R65313 m SAS Cable1
The following table lists the drives that are supported by EXP2512 external expansion enclosures.

Table 23. Drive options for EXP2512 external expansion enclosures
Part numberDescriptionMaximum quantity supported per one enclosure
3.5" NL SAS HS HDDs
00NC5552TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
00NC5573TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
00NC5594TB 7,200 rpm 6Gb SAS NL 3.5" HDD12

The following table lists the hard disk drives that are supported by EXP2524 external expansion enclosures.

Table 24. Drive options for EXP2524 external expansion enclosures
Part numberDescriptionMaximum quantity supported per one enclosure
2.5" NL SAS HS HDDs
00NC5711TB 7,200 rpm 6Gb SAS NL 2.5" HDD24
2.5" SAS HS HDDs
00NC561146GB 15,000 rpm 6Gb SAS 2.5" HDD24
00NC563300GB 15,000 rpm 6Gb SAS 2.5" HDD24
00NC565600GB 10,000 rpm 6Gb SAS 2.5" HDD24
00NC567900GB 10,000 rpm 6Gb SAS 2.5" HDD24
00NC5691.2TB 10,000 rpm 6Gb SAS 2.5" HDD24
2.5" SAS HS SSDs
00NC573200GB 6Gb SAS 2.5" SSD24
00NC575400GB 6Gb SAS 2.5" SSD24

External disk storage systems

The following table lists the external storage systems that are supported by the server and can be ordered through the System x sales channel. The server may support other disk systems that are not listed in this table. For further information, refer to the IBM System Storage Interoperation Center at: http://www.ibm.com/systems/support/storage/ssic

Table 25. External disk storage systems

Part numberDescription
2071CU2IBM Storwize V3500 LFF Dual Control Enclosure
2071CU3IBM Storwize V3500 SFF Dual Control Enclosure
6099L2CIBM Storwize V3700 3.5-inch Storage Controller Unit
6099S2CIBM Storwize V3700 2.5-inch Storage Controller Unit
6099T2CIBM Storwize V3700 2.5-inch DC Storage Controller Unit
6194L2CIBM Storwize V5000 LFF Control Enclosure
6194LEUIBM Storwize V5000 LFF Expansion Enclosure
6194S2CIBM Storwize V5000 SFF Control Enclosure
6194SEUIBM Storwize V5000 SFF Expansion Enclosure
6195SC5IBM Storwize V7000 2.5-inch Storage Controller Unit
 6195LEFIBM Storwize V7000 3.5-inch Storage Expansion Unit
 6195SEFIBM Storwize V7000 2.5-inch Storage Expansion Unit

For more information, see the list of Lenovo Press Product Guides in the System Storage category:
http://lenovopress.com/systemx/externalstorage

External backup units

The server supports the external backup attachment options listed in the following table.

Table 26. External backup options

Part numberDescription
External tape expansion enclosures for internal tape drives
87651UX1U Tape Drive Enclosure
87651NX1U Tape Drive Enclosure (with Nema 5-15P LineCord)
Tape enclosure adapters (with cables)
44E8869USB Enclosure Adapter Kit
40K2599SAS Enclosure Adapter Kit
Internal backup drives supported by external tape enclosures
00D2786RDX Internal USB 3.0 Dock with 320GB Cartridge
00D2787RDX Internal USB 3.0 Dock with 500GB Cartridge
00D2788RDX Internal USB 3.0 Dock with 1TB Cartridge
49Y9898Half High LTO Gen 5 Internal SAS Tape Drive
00D8924Half High LTO Ultrium Gen 6 Internal SAS Tape Drive
External backup units*
362532YRDX External USB 3.0 Dock with 320GB Cartridge
362550YRDX External USB 3.0 Dock with 500GB Cartridge
36251TYRDX External USB 3.0 Dock with 1TB Cartridge
3628L5X Half High LTO Gen 5 External SAS Tape Drive (with US line cord)
3628N5XHalf High LTO Gen 5 External SAS Tape Drive (without line cord)
* These external tape drives can be ordered through the System x sales channel. The server might support other tape drives that are not listed in this table. See the IBM System Storage Interoperation Center (SSIC) for further information.

For more information, see the list of Lenovo Press Product Guides in the Backup units category:
http://lenovopress.com/systemx/tape

Top-of-rack Ethernet switches

The server supports the top-of-rack Ethernet switches from Lenovo listed in the following table.

Table 27. Top-of-rack switches

Part numberDescription
1 Gb top-of-rack switches
7159BAXLenovo RackSwitch G7028 (Rear to Front)
7159CAXLenovo RackSwitch G7052 (Rear to Front)
715952FLenovo RackSwitch G8052 (Front to Rear)
7159G52Lenovo RackSwitch G8052 (Rear to Front)
10 Gb top-of-rack switches
7159BF7Lenovo RackSwitch G8124E (Front to Rear)
7159BR6Lenovo RackSwitch G8124E (Rear to Front)
715964FLenovo RackSwitch G8264 (Front to Rear)
7159G64Lenovo RackSwitch G8264 (Rear to Front)
7159DFXLenovo RackSwitch G8264CS (Front to Rear)
7159DRXLenovo RackSwitch G8264CS (Rear to Front)
7159CFVLenovo RackSwitch G8272 (Front to Rear)
7159CRWLenovo RackSwitch G8272 (Rear to Front)
7159GR5Lenovo RackSwitch G8296 (Front to Rear)
7159GR6Lenovo RackSwitch G8296 (Rear to Front)
40 Gb top-of-rack switches
7159BFXLenovo RackSwitch G8332 (Front to Rear)
7159BRXLenovo RackSwitch G8332 (Rear to Front)

For more information, see the list of Lenovo Press Product Guides in the Top-of-rack switches category:
http://lenovopress.com/systemx/tor

Uninterruptible power supply units

The server supports attachment to the uninterruptible power supply (UPS) units listed in the following table.

Table 28. Uninterruptible power supply units

Part numberDescription
Rack-mounted or tower UPS units
55941AXRT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KXRT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AXRT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KXRT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AXRT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KXRT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KXRT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KXRT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KXRT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KXRT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PXRT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PXRT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
Rack-mounted UPS units
53951AX1500VA LCD 2U Rack UPS (100V/120V)
53951KX1500VA LCD 2U Rack UPS (230V)
53952AX2200VA LCD 2U Rack UPS (100V/120V)
53952KX2200VA LCD 2U Rack UPS (230V)
53953AX 3000VA LCD 3U Rack UPS (100 V/120 V)
53953JX 3000VA LCD 3U Rack UPS (200 V/208 V)
53956AX 6000VA LCD 4U Rack UPS (200 V/208 V)
53956KX 6000VA LCD 4U Rack UPS (230 V)
53959KX11000VA LCD 5U Rack UPS (200V/208V/230V)

For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category:
http://lenovopress.com/systemx/power


Power distribution units

The server supports attachments to the power distribution units (PDUs) that are listed in the following table.

Table 29. Power distribution units
Part numberDescription
Switched and Monitored PDUs
46M4002 1U 9 C19/3 C13 Active Energy Manager DPI® PDU
46M4003 1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU
46M4004 1U 12 C13 Active Energy Manager DPI PDU
46M4005 1U 12 C13 Active Energy Manager 60A 3 Phase PDU
46M41671U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU
46M41160U 24 C13 Switched and Monitored 30A PDU
46M41190U 24 C13 Switched and Monitored 32A PDU
46M41340U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU
46M41370U 12 C19/12 C13 Switched and Monitored 32A 3 Phase PDU
Enterprise PDUs
71762MX Ultra Density Enterprise PDU C19 PDU+ (WW)
71762NX Ultra Density Enterprise PDU C19 PDU (WW)
71763MU Ultra Density Enterprise PDU C19 3 Phase 60A PDU+ (NA)
71763NU Ultra Density Enterprise PDU C19 3 Phase 60A PDU (NA)
39M2816DPI C13 Enterprise PDU without linecord
39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed power cord
39Y8941 DPI Single Phase C13 Enterprise PDU without power cord
39Y8948 DPI Single Phase C19 Enterprise PDU without power cord
Front-end PDUs
39Y8934DPI 32 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector
39Y8935DPI 63amp/250 V Front-end PDU with IEC 309 2P+Gnd connector
39Y893830 amp/125 V Front-end PDU with NEMA L5-30P connector
39Y893930 amp/250 V Front-end PDU with NEMA L6-30P connector
39Y894060 amp/250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector
Universal PDUs
39Y8951DPI Universal Rack PDU with US LV and HV power cords
39Y8952DPI Universal Rack PDU with CEE7-VII Europe LC
39Y8953DPI Universal Rack PDU with Denmark LC
39Y8954DPI Universal Rack PDU with Israel LC
39Y8955 DPI Universal Rack PDU with Italy LC
39Y8956DPI Universal Rack PDU with South Africa LC
39Y8957DPI Universal Rack PDU with UK LC
39Y8958DPI Universal Rack PDU with AS/NZ LC
39Y8959DPI Universal Rack PDU with China LC
39Y8962DPI Universal Rack PDU (Argentina)
39Y8960DPI Universal Rack PDU (Brazil)
39Y8961DPI Universal Rack PDU (India)
0U Basic PDUs
46M41220U 24 C13 16A 3 Phase PDU
46M4125 0U 24 C13 30A 3 Phase PDU
46M4128 0U 24 C13 30A PDU
46M41310U 24 C13 32A PDU
46M4140 0U 12 C19/12 C13 60A 3 Phase PDU
46M41430U 12 C19/12 C13 32A 3 Phase PDU

For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category:
http://lenovopress.com/systemx/power

Rack cabinets

The server supports the rack cabinets that are listed in the following table.

Table 30. Rack cabinets

Part numberDescription
201886X11U Office Enablement Kit
93072RX25U Standard Rack
93072PX25U Static S2 Standard Rack
93634EX42U 1100mm Dynamic Expansion Rack
93634PX42U 1100mm Dynamic Rack
93604EX42U 1200mm Deep Dynamic Expansion Rack
93604PX42U 1200mm Deep Dynamic Rack
93614EX42U 1200mm Deep Static Expansion Rack
93614PX42U 1200mm Deep Static Rack
93084EX42U Enterprise Expansion Rack
93084PX42U Enterprise Rack
93074RX42U Standard Rack
93074XX42U Standard Rack Extension
93624EX47U 1200mm Deep Static Expansion Rack
93624PX47U 1200mm Deep Static Rack
93634DXPureFlex™ System 42U Expansion Rack
93634CXPureFlex System 42U Rack

For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category:
http://lenovopress.com/systemx/rack

Rack options

The server supports the rack console switches and monitor kits that are listed in the following table.

Table 31. Rack options

Part numberFeature codeDescription
Monitor kits and keyboard trays
17238BX1723HC1 fc A3EK1U 18.5" Standard Console
17238EX1723HC1 fc A3EL1U 18.5" Enhanced Media Console
172317X1723HC1 fc 00511U 17in Flat Panel Console Kit
172319X1723HC1 fc 00521U 19in Flat Panel Console Kit
Console switches
3858D3X3858HC1 fc A4X1Avocent Universal Management Gateway 6000
1754D2X1754HC2 fc 6695Global 4x2x32 Console Manager (GCM32)
1754D1X1754HC1 fc 6694Global 2x2x16 Console Manager (GCM16)
1754A2X1754HC4 fc 0726Local 2x16 Console Manager (LCM16)
1754A1X1754HC3 fc 0725Local 1x8 Console Manager (LCM8)
Console cables
00AK142A4X4UM KVM Module VGA+SD Dual RJ45
43V61473757Single Cable USB Conversion Option (UCO)
39M28953756USB Conversion Option (4 Pack UCO)
39M28973754Long KVM Conversion Option (4 Pack Long KCO)
46M53835341Virtual Media Conversion Option Gen2 (VCO2)
46M53825340Serial Conversion Option (SCO)

For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category:
http://lenovopress.com/systemx/rack

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovo.com/services_warranty/us/en/financial_services.html

Related publications and links

For more information, see these resources:


Special Notices

This material has not been submitted to any formal IBM test and is published AS IS. It has not been the subject of rigorous review. IBM assumes no responsibility for its accuracy or completeness. The use of this information or the implementation of any of these techniques is a client responsibility and depends upon the client's ability to evaluate and integrate them into the client's operational environment.

Profile

Publish Date
16 January 2014

Last Update
03 June 2015


Rating: Not yet rated


Author(s)

IBM Form Number
TIPS1102