Abstract
There are four expansion blades currently available for IBM BladeCenter servers:
IBM BladeCenter Memory and I/O Expansion Unit, part number 42C1600
IBM BladeCenter Storage and I/O (SIO) Expansion Unit, part number 39R7563
IBM BladeCenter PCI Expansion Unit II (PEU2), part number 25K8373
IBM BladeCenter PCI Express I/O Expansion Unit (PEU3e), 43W4391
The expansion blades add function to the blade server by adding additional memory DIMMs, Ethernet controllers, and I/O expansion slots. In this technote, we list the blade server models that support these expansion blades.
Contents
There are four expansion blades currently available for IBM BladeCenter servers:
- Memory and I/O Expansion Unit, which has four memory DIMM sockets, two Ethernet controllers, and PCI-X and PCI Express I/O expansion sockets
- Storage and I/O (SIO) Expansion Unit, which has three SAS drive bays, RAID controller, and two PCI-X and one PCI Express I/O expansion sockets
- PCI Expansion Unit II (PEU2), which has two full-length PCI-X 100 MHz slots
- PCI Express I/O Expansion Unit (PEU3e), which has two full length PCI Express x8 (x16 mechanical) slots
Attaching one expansion blade
These expansion blades attach to the server blade and double the width of the overall server. In some configurations, two expansion blades can be attached to a single blade server. Table 1 lists the available expansion blades and the servers that support them.
Note: The QS22 and PN41 blade servers do not support any expansion blades or expansion cards as they do not have the necessary onboard connectors.
Table 1. Available expansion blades and the servers that support them
Expansion card | ||||||||||||||
IBM BladeCenter Memory and I/O (MIO) Expansion Unit, 42C1600 | N | N | Y | N | N | N | N | N | N | N | N | N | N | N |
IBM BladeCenter Storage and I/O (SIO) Expansion Unit, 39R7563 | N | Y | Y | Y | N | Y | Y | Y | Y | N | N | N | N | N |
IBM BladeCenter PCI Expansion Unit II (PEU2), 39R7563 | N | N | Y | Y | N | N | Y | N | Y | N | N | N | N | N |
IBM BladeCenter PCI Express I/O Expansion Unit (PEU3e), 43W4391 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | N | N | N |
Attaching two expansion blades
As you can see Table 1, the HS21, HS21 XM, LS21/41, and LS22/42 support more than one expansion blade. There are configuration requirements that are related to connecting multiple expansion blades, as described in this section. You can only attach one blade of each type (for example, only one SIO expansion blade).
BladeCenter HS21
For the HS21, you can only attach two expansion blades to the server blade. Attaching three expansion blades is not supported. The following configurations are supported (the sequence is important; the MIO must be directly attached to the HS21, for example):
- HS21 <- MIO <- PEU2
- HS21 <- MIO <- SIO
- HS21 <- SIO <- PEU2
The following configurations are unsupported combinations:
- HS21 <- PEU2 <- MIO (not supported)
- HS21 <- SIO <- MIO (not supported)
- HS21 <- PEU2 <- SIO (not supported)
Although the HS21 supports all three expansion blades, only two expansion blades can be attached to a server at one time. If used, the MIO must be the “closest” expansion blade to the blade server.
BladeCenter HS21 XM
For the HS21 XM, the SIO and PEU2/PEU3e can be attached at the same time, in the following connection sequence:
- HS21 XM <- SIO <- PEU2
- HS21 XM <- SIO <- PEU3e (only the first slot in the PEU3e will work in this configuration)
The following connection sequences are unsupported combinations:
- HS21 XM <- PEU2 <- SIO (not supported)
- HS21 XM <- PEU3e <- SIO (not supported)
BladeCenter LS21
For LS21, the SIO and PEU3e can be attached at the same time, in the following connection sequence:
- LS21 <- SIO <- PEU3e (only the first slot in the PEU3e will work in this configuration)
The following connection sequence is an unsupported combination:
- LS21 <- PEU3e <- SIO (not supported)
BladeCenter LS41
For LS41, the SIO and PEU3e can be attached at the same time, in the following connection sequence:
- LS41 <- MPE <- SIO <- PEU3e (only the first slot in the PEU3e will work in this configuration)
The following connection sequence is an unsupported combination:
- LS41 <- MPE <- PEU3e <- SIO (not supported)
BladeCenter LS22
For LS22, the SIO and PEU2 or SIO and PEU3e, can be attached at the same time, in the following connection sequence:
- LS22 <- SIO <- PEU2
- LS22 <- SIO <- PEU3e (only the first slot in the PEU3e will work in this configuration)
The following connection sequence is an unsupported combination:
- LS22 <- PEU2 <- SIO (not supported)
- LS22 <- PEU3e <- SIO (not supported)
For LS42 with the Multi Processor Expansion (MPE) Unit, the SIO and PEU2 or SIO and PEU3e, can be attached at the same time, in the following connection sequence:
- LS42 <- MPE <- SIO - PEU2
- LS42 <- MPE <- SIO - PEU3e (only the first slot in the PEU3e will work in this configuration)
The following connection sequence is an unsupported combination:
- LS42 <- MPE <- PEU2 <- SIO (not supported)
- LS42 <- MPE <- PEU3e <- SIO (not supported)
Related publications
For more information, see the following documents:
- IBM Redbooks publication IBM BladeCenter Products and Technology, SG24-7523
http://www.redbooks.ibm.com/abstracts/sg247523.html - IBM BladeCenter Interoperability Guide
http://www.ibm.com/support/docview.wss?uid=psg1MIGR-5073016 - IBM BladeCenter Storage and I/O (SIO) Expansion Unit Installation and User's Guide
http://www.ibm.com/support/docview.wss?uid=psg1MIGR-5070759 - IBM BladeCenter Memory and I/O Expansion Blade Installation Guide
http://www.ibm.com/support/docview.wss?uid=psg1MIGR-5070758 - IBM BladeCenter PCI Expansion Unit II (PEU2) Installation Instructions
http://www.ibm.com/support/docview.wss?uid=psg1MIGR-61501 - IBM BladeCenter PCI Express I/O Expansion Unit (PEU3e)
http://www.ibm.com/support/docview.wss?uid=psg1MIGR-5076806
Special Notices
This material has not been submitted to any formal IBM test and is published AS IS. It has not been the subject of rigorous review. IBM assumes no responsibility for its accuracy or completeness. The use of this information or the implementation of any of these techniques is a client responsibility and depends upon the client's ability to evaluate and integrate them into the client's operational environment.