-->
Skip to main content

ServeRAID Adapter Quick Reference

Redbooks logo

Abstract

Have you ever picked up an adapter that you know is a ServeRAID adapter, but do not know which model? This tip is a quick reference guide to the different ServeRAID adapters that are available, complete with photos and tables of features and supported servers.

Contents

New in this update:

  • Corrected the list of countries where the ServeRAID MR10il is available

This document is a quick guide to the different ServeRAID adapters that IBM has produced since their introduction in mid-1996. For customers who have the older adapters, this document will help identify which adapters you have with photos and a key features table.

Table of contents:




Photos of ServeRAID adapters


Jump to:





ServeRAID (part number 70G8489, 1996)


US Announcement Letter: 196-134

Visual identifiers:

  • Single external 68-pin industry-standard SCSI connector (all other ServeRAID cards use VHDCI connectors)
  • Three internal 68-pin industry-standard SCSI connectors
  • Connector located vertically in the center of the board (unused)
ServeRAID


ServeRAID II (part 76H3584, 1997)


US Announcement Letter: 197-256

Visual identifiers:

  • Two external VHDCI (very high density connector interface) connectors
  • Three internal 68-pin industry-standard SCSI connectors
  • Optional cable to route channel 3 externally
ServeRAID II
Optional cable (part 76H5400) routes channel 3 to an external connector:
ServeRAID II adapter with 3rd channel cable


ServeRAID-3L (part 01K7364, 1998) and ServeRAID-3L II (part 19K0564, 2000)


US Announcement Letters:


Visual identifiers:
  • One external VHDCI connector, labeled "LVD/SE"
  • One internal 68-pin industry-standard SCSI connector
  • 32-bit PCI connector (short)

The photo below is that of the ServeRAID-3L. Note that the internal connector is not on an indentation in the circuit board.
ServeRAID-3L
The ServeRAID-3L was replaced by the ServeRAID-3L II (part 19K0564) in April 2000. The internal connector of the ServeRAID-3L II adapter has been redesigned so that the adapter will fit in 3U servers, such as the Netfinity 4500R. This board design is the only difference. In fact, the two adapters are the same FRU, 01K7352.



ServeRAID-3H (part 01K7207, 1998)


US Announcement Letter: 198-232

Visual identifiers:

  • Two external VHDCI connectors, labeled "LVD/SE"
  • Single internal 68-pin industry-standard SCSI connector
  • Connector on the top edge of the card with EDO memory DIMM installed
  • Might have an optional daughter card with a battery pack (part 28L1003) installed into the connector near the handle. This adapter looks similar to the ServeRAID-3HB.
  • 64-bit PCI connector (long)

Note: The adapter also includes a cable similar to ServeRAID II option to route the internal channel 3 connector to an external VHDCI connector (not shown).
ServeRAID-3H


ServeRAID-3HB (part 37L6086, 1999)


US Announcement Letter: 199-152

Visual identifiers:

  • Same as ServeRAID-3H adapter except battery backup module is standard
ServeRAID-3HB



ServeRAID-4L (part 37L6091, 2000)


US Announcement Letter: 100-099

Visual identifiers:

  • One external VHDCI connector
  • One internal 68-pin industry-standard SCSI connector
  • Space for two internal connectors, but only one present (same circuit board as the 4M)
ServeRAID-4L


ServeRAID-4Lx (part 06P5740, 2001)


US Announcement Letter: 101-146

Visual identifiers:

  • Half-length card
  • Square heat sink in the middle of the card
  • One external VHDCI connector
  • One internal 68-pin industry-standard SCSI connector
  • 64-bit PCI connector (long)
ServeRAID-4Lx



ServeRAID-4M (part 37L6080, 2000)


US Announcement Letter: 100-099

Visual identifiers:

  • Two external VHDCI connectors
  • Two internal 68-pin industry-standard SCSI connectors
  • Battery integrated into a daughter card lengthwise along card, near handle
  • No heat sinks (4Mx has heat sinks)

ServeRAID-4M


ServeRAID-4Mx (part 06P5736, 2001)


US Announcement Letter: 101-146

Visual identifiers:

  • Similar to ServeRAID-4M (check for heat sinks)
  • Two external VHDCI connectors
  • Two internal 68-pin industry-standard SCSI connectors
  • Battery integrated into a daughter card lengthwise along card, near handle
  • Heat sink on central chip and smaller chip near PCI connector
ServeRAID-4Mx


ServeRAID-4H (part 37L6889, 2000)


US Announcement Letter: 100-099

Visual identifiers:

  • Four external VHDCI connectors
  • Two internal 68-pin industry-standard SCSI connectors
  • Large daughter card with battery attached to the main board
ServeRAID-4H


ServeRAID-5i (part 25P3492, 2002)


US Announcement Letter: 102-170

Visual identifiers:

  • No internal or external SCSI connectors (uses the server's onboard SCSI)

ServeRAID-5i


ServeRAID-6M

128 MB cache: part 32P0033, 2003 and 39R8815, 2006
256 MB cache: part 02R0988, 2003 and 39R8816, 2006

US Announcement Letter: 103-206

Visual identifiers:

  • Two external connectors and two internal connectors
  • Adaptec name and logo printed on the board (not IBM)
  • Two notches in the PCI connector, not three - indicating that it is a 3.3V adapter, not a combo 3.3V+5V adapter
  • One DIMM attached to the bottom edge of the card (see photo) for the cache
  • The 128 MB DIMM has five chips (as shown in the photo); the 256 DIMM has nine chips

Note: The battery shown in the photo is not a production-level battery.


ServeRAID-6M



ServeRAID-6i (part 71P8595, 2003) and ServeRAID-6i+ (part 13N2190, 2004 and 39R8793, 2006)


US Announcement Letters:


Visual identifiers:
  • No internal or external SCSI connectors (uses the server's onboard SCSI)
  • Two notches in the PCI connector (versus four notches in the ServeRAID-5i)

Notes:
  • The 6i and 6i+ are physically identical adapters. The only difference is that the 6i+ is flashed at the factory to V7.0 firmware to support the x206 and x306. A ServeRAID-6i+ is supported in servers that support the ServeRAID-6i.
  • The battery shown in the photo is not a production-level battery.


ServeRAID-6i



ServeRAID 7t (part 71P8648, 2004 and 39R8805, 2006)


US Announcement Letter: 104-075

Visual identifiers:

  • Four internal Serial ATA (SATA) connectors
  • No external connectors

ServeRAID 7t



ServeRAID 7e (2004)


Visual identifier:

  • No extra hardware
  • Function is integrated into the SCSI controller, SATA controller, or both of specific xSeries servers and enabled with software
  • See the Supported servers table for the servers with this controller built in.





ServeRAID 7k (part 71P8642, 2004 and 39R8800, 2006)


US Announcement Letter: 104-284 (announced with the x346)

Visual identifiers:

  • The option is shipped as a special memory DIMM with a battery attached (for battery-backup purposes)
  • Memory is 256 MB, 133 MHz (PC2100) DDR1 memory

ServeRAID 7k



ServeRAID 8e (2005)


Visual identifiers:

  • No extra hardware
  • Function is integrated into the SAS or SATA controller of specific xSeries servers and enabled with software
  • See the Supported servers table for the servers with this controller built in.





ServeRAID 8i (part 13N2227, 2005) and ServeRAID 8i (part 39R8729, 2005)


US Announcement Letters:
Part 13N2227: 105-125 (announced with the x366)
Part 39R8729: 105-414 (announced with x206m)

Visual identifiers:

  • Blue circuit board
  • The card will either have a blue handle attached (for use with x260, x366, x460) or a PCI bracket attached (for use with x206m and x306m)
  • No connectors for disks
  • Battery attached
  • The two part numbers are identical electronics - the difference is the level of firmware installed at the factory. Packaging is also different as follows:
  • Part 13N2227: Has the blue handle attached by default, with the PCI bracket in the box
  • Part 39R8729: Has the PCI bracket attached by default, with the blue handle in the box

A note about the two part numbers and firmware: 13N2227 was introduced with the x366 and may have V8.00 or later firmware. 39R8729 was introduced with the x206m and ships with V8.15 or later firmware. 39R8729 will replace 13N2227. The cards are interchangable, but a ServeRAID-8i installed in the x206m and x306m must have V8.15 firmware or later. A card with firmware ealier than V8.15 will not function in an x206m or x306m. In addition, you cannot upgrade the firmware of the card to V8.15 while it is installed in an x206m or x306m if it has older firmware - you must upgrade the firmware in another system.

ServeRAID-8i





ServeRAID 8k-l (2006)


US Announcement Letter: 106-379 (announced with the System x3650)

Visual identifiers:

  • A special memory DIMM, but no battery attached (unlike ServeRAID 8k)
  • One DRAM chip on the DIMM
  • No cache for data (see RETAIN tip H187701 for clarification)
  • See the Supported servers table for the servers with this controller standard

Photo not currently available. The DIMM is similar to the ServeRAID 8k but with only one DRAM chip and no battery.



ServeRAID 8k (25R8064, 2006)


US Announcement Letter: 106-379 (announced with the System x3650)

Visual identifiers:

  • The option is shipped as a special memory DIMM with a battery attached via wires (for battery-backup purposes)
  • The DIMM is installed in a special DIMM socket in supported servers
  • Five DRAM chips on the DIMM
  • FRU on label is 25R8076; Stamped "Adaptec ATB-200" on battery side
  • Write-back cache memory is 256 MB, 533 MHz DDR2 unbuffered memory
  • Battery is connected to the DIMM by wires and is typically mounted on the server chassis

ServeRAID 8k (battery not shown)

ServeRAID 8k installed in an x3650



ServeRAID-8s (39R8765, 2007)


US Announcement Letter: 107-028

Visual identifiers:

  • One x4 external SFF-8470 SAS connector
  • Two x4 internal SFF-8484 SAS connectors
  • 3/4 length, full height board
  • Large fan on the board
  • Optional battery (option part number 39R8812)
  • Optional internal cable for hot-swap System x3250 models and hot-swap x3200 models (43W4908)
  • Optional internal cable for simple-swap x3200 models (43W4910)

ServeRAID-8s



IBM SAS HBA Controller (25R8060, 2006)


US Announcement Letter: 106-646

Visual identifiers:

  • 1 external Mini-SAS x4 connector (SFF-8088)
  • 4 internal SATA x1 connectors


IBM SAS HBA Controller



MegaRAID (39R8850, 2006)


US Announcement Letter: 106-640

Visual identifiers:

  • Two SAS SFF8470 x4 external connectors
  • Intelligent Transportable Battery Backup (iTBBU)
  • 256 MB DDR2 SDRAM data cache





ServeRAID-MR10M (43W4339, 2007)


US Announcement Letter: 107-594

Visual identifiers:

  • MD2 form factor card (2U low profile height)
  • Two SFF-8088 external connectors
  • Large battery attached to the card



ServeRAID-MR10M



ServeRAID-MR10k (43W4280, 2007)


US Announcement Letter: 107-594

Visual identifiers:

  • Looks like a memory DIMM
  • Intelligent Transportable Battery Backup (iTBBU) connected via wires
  • Battery mounted in side of PCI slot spacer

MR10k installed in the x3850 M2

MR10k with battery




ServeRAID-MR10i (43W4296, 2008)


US Announcement Letter: 108-055 (part of System x3350 announcement)

Visual identifiers:

  • No external connectors
  • Full height (3U), half length card
  • Two x4 SFF-8087 connectors on right side of card
  • Optional battery attaches to the card

ServeRAID-MR10i



ServeRAID-MR10il (44E8767, 2008)


Asia Pacific Announcement Letter: AG08-0353 (announced in China only)

Visual identifiers:

  • No external connectors
  • Low-profile MD2 half-length 2U form factor adapter card.
  • Two x4 SFF-8087 connectors on left side of card

ServeRAID-MR10il



ServeRAID-BR10i (44E8767, 2008)


US Announcement Letter: N/A

Visual identifiers:

  • No external connectors
  • Low-profile MD2 half-length 2U form factor adapter card.
  • Two x4 mini-SAS SFF-8087 connectors on right side of card

ServeRAID-BR10i




ServeRAID-BR10il (44X0411, 2008)


US Announcement Letter: 108-352

Visual identifiers:

  • Rectangular card with custom connector
  • 1 x4 mini-SAS SFF-8087 connector
  • LSI 1064E controller chip

ServeRAID-BR10il




Feature comparison


The following three tables provide a comparison of features between the members of the ServeRAID family and other RAID controllers sold by IBM.

RAID controller device driver downloads: http://www-304.ibm.com/jct01004c/systems/support/supportsite.wss/docdisplay?lndocid=MIGR-65723&brandind=5000008

Jump to:
ServeRAID 1-4 adapters
ServeRAID 5-7 adapters
ServeRAID 8-10 adapters


Feature         SRSR-IISR-3LSR-3L II*SR-3HSR-3HBSR-4LSR-4LxSR-4MSR-4MxSR-4H
SCSI or SATASCSISCSISCSISCSISCSISCSISCSISCSISCSISCSISCSI
First available19961997199820001998199920002001200020012000
US Announcement Letter196-134197-256198-232100-101198-232199-152100-099101-146100-099101-146100-099
Marketing part number70G848976H358401K736419K056401K720737L608637L609106P574037L608006P573637L6889
FRU part number (adapter only)06H933476H358737L6083
01K7352
01K735201K739601K7396 09N954006P574137L725806P573737L6892
Useful linksDrivers Drivers Drivers Drivers Drivers Drivers Guide
Drivers
Guide
Drivers
Guide
Drivers
Guide
Drivers
Guide
Drivers
Internal connectors33111111222
External connectors (std/max)1/12/31/11/12/32/31/11/12/22/24/4
Cable for extra external connectorNoneOptional
76H5400
NoneNoneIncludedIncludedNoneNoneNoneNoneNone
External connector type68 pinVHDCIVHDCIVHDCIVHDCIVHDCIVHDCIVHDCIVHDCIVHDCIVHDCI
Cache4 MB4 MB4 MB4 MB32 MB32 MB16 MB32 MB64 MB64 MB128 MB
Battery backup for cacheNoOptional
76H5401
28L1003
NoNoOptional
28L1003
(Poseidon)
Yes
(Poseidon)
NoNoYesYesYes
SCSI channels / SATA ports33113311224
Disks per channel (SCSI) or port (SATA)1515151515151514151415
SCSI levelSCSI F/WUltraUltra2Ultra2Ultra2Ultra2Ultra160Ultra160Ultra160Ultra160Ultra160
PCI or PCI-X or PCI ExpressPCIPCIPCIPCIPCIPCIPCIPCIPCIPCIPCI
PCI bus speed33 MHz33 MHz33 MHz33 MHz33 MHz33 MHz33 MHz66 MHz33 MHz66 MHz33 MHz
PCI bus width32 bit32 bit32 bit32 bit64 bit64 bit64 bit64 bit64 bit64 bit64 bit
PCI bus voltage5V5V5V5V5V5V3.3 or 5V3.3 or 5V3.3 or 5V3.3 or 5V3.3 or 5V
AutosyncNoYesYesYesYesYesYesYesYesYesYes
"Optimal" SCSI speed settingNoNoYesYesYesYesYesYesYesYesYes
LVDS supportNoNoYesYesYesYesYesYesYesYesYes
I2O enabledNoNoYesYesYesYesYesYesYesYesYes
Active PCI support (hot-swap)NoYesYesYesYesYesYesYesYesYesYes
Clustering supportNoNoNoNoYesYesYesYesYesYesYes
Usable in a fault-tolerant pair NoYesYesYesYesYesYesYesYesYesYes
Data scrubbingNoYesYesYesYesYesYesYesYesYesYes
FlashcopyNoNoYesYesYesYesYesYesYesYesYes
CopybackNoNoNoNoNoNoNoNoNoNoNo
Maximum stripe size64 KB64 KB64 KB64 KB64 KB64 KB64 KB64 KB64 KB64 KB64 KB
RAID-0 and RAID-1 supportYesYesYesYesYesYesYesYesYesYesYes
RAID-5 supportYesYesYesYesYesYesYesYesYesYesYes
RAID-1E supportYesYesYesYesYesYesYesYesYesYesYes
RAID-5E supportNoNoYesYesYesYesYesYesYesYesYes
RAID-5EE support (replaces 5E)NoNoNoNoNoNoNoYesNoYesNo
RAID-6NoNoNoNoNoNoNoNoNoNoNo
RAID-00 supportNoNoNoNoNoNoYesYesYesYesYes
RAID-10 supportNoNoNoNoNoNoYesYesYesYesYes
RAID-1E0 supportNoNoNoNoNoNoYesYesYesYesYes
RAID-50 supportNoNoNoNoNoNoYesYesYesYesYes
RAID-60 supportNoNoNoNoNoNoNoNoNoNoNo
Feature         SRSR-IISR-3LSR-3L II*SR-3HSR-3HBSR-4LSR-4LxSR-4MSR-4MxSR-4H

* The ServeRAID-3L II, part 19K0564, replaced the ServeRAID-3L. The ServeRAID-3L and ServeRAID-3L II have identical features and support the same servers. The ServeRAID-3L II has a different card design so that it will fit vertically in 3U servers.


Feature         SR-5iSR-6MSR-6MSR-6iSR-6i+SR 7tSR 7eSR 7k
SCSI or SATA or SASSCSISCSISCSISCSISCSISATASCSI, SATASCSI
First available20022003200320032004200420042004
US Announcement Letter102-170103-206103-206103-210 104-078104-075104-284
Marketing part number25P349232P0033
39R8815
02R0988
39R8816
71P859513N2190
39R8793
71P8648
39R8805
None71P8642
39R8800
FRU part number (adapter only)32P001602R0985
39R8817
02R0998
39R8818
71P8627Adaptec 2108800
39R8795
Adaptec 2410SA
39R8807
Not applicable (software)90P5245
ATB-100
39R8801
ProcessorIntel IOP321 600MHzIntel IOP321 600MHzIntel IOP321 400MHz80302Not applicableIntel IOP332
Useful linksGuide
Drivers
Drivers Drivers Drivers Drivers Drivers Drivers Drivers
Internal connectors02200400
External connectors (std/max)02/22/200000
Cable for extra external connectorNoneNoneNoneNoneNoneNoneNoneNone
External connector typeNoneVHDCIVHDCINoneNoneNoneNoneNone
Cache128 MB128 MB256 MB128 MB128 MB64 MBNone256 MB
Battery backup for cacheYesYesYesYesYesNoNoYes
SCSI channels / SATA ports / SAS ports1 on server221 or 2 on server1 or 2 on server41 or 22 on server
Disks per channel (SCSI) or port (SATA/SAS)14141414141Varies14
SCSI levelUltra320Ultra320Ultra320Ultra320Ultra320SATAUltra320Ultra320
PCI or PCI-X or PCI ExpressPCIPCI-XPCI-XPCI-XPCI-XPCIPCI-XPCI-X 1.0
PCI bus speed66 MHz133 MHz133 MHz133 MHz133 MHz66 MHzVaries100 MHz
PCI bus width64-bit64-bit64-bit64-bit64-bit64-bit64-bit64-bit
PCI bus voltage3.3 or 5V3.3V3.3V3.3V3.3V3.3V or 5VNot applicableNot applicable
AutosyncYesYesYesYesYesYesYesYes
"Optimal" SCSI speed setting YesYesYesYesYesNot applicableYesYes
LVDS supportYesYesYesYesYesNot applicableYesYes
I2O enabledYesYesYesYesYesNoNot applicableYes
Active PCI support (hot-swap)NoNoNoNoNoNoNoNo
Clustering supportNoYesYesNoNoNoNoNo
Usable in a fault-tolerant pair NoYesYesNoNoNoNoNo
Data scrubbingYesYesYesYesYesNoNoYes
FlashcopyNoYesYesYesYesYesNoYes
CopybackNoNoYesYesYesNoNoYes
Maximum stripe size64 KB64 KB64 KB64 KB64 KB64 KB64 KB64 KB
RAID-0 and RAID-1 supportYesYesYesYesYesYesYesYes
RAID-5 supportYesYesYesYesYesYesNoYes
RAID-1E supportYesYesYesYesYesNoNoYes
RAID-5E supportNoNoNoNoNoNoNoNo
RAID-5EE support (replaces 5E)NoYesYesYesYesNoNoYes
RAID-6NoNoNoNoNoNoNoNo
RAID-00 supportNoYesYesYesYesNoNoYes
RAID-10 supportYesYesYesYesYesYesNoYes
RAID-1E0 supportNoYesYesYesYesNoNoYes
RAID-50 supportYesYesYesYesYesNoNoYes
RAID-60 supportNoNoNoNoNoNoNoNo
Feature      SR-5iSR-6MSR-6MSR-6iSR-6i+SR 7tSR 7eSR 7k

Feature    SR 8iSR 8eSR 8k-lSR 8kSR-8sSAS HBAMegaRAIDSR-MR10MSR-MR10kSR-MR10iSR-MR10ilSR-BR10iSR-BR10il
SCSI or SATA or SASSAS, SATASAS, SATASAS, SATASAS, SATASAS, SATASAS, SATASAS, SATASAS, SATASASSAS, SATASAS, SATASAS, SATASAS, SATA
First available2005200520062006200720062006200720072008200820082008
US Announcement Letter105-125106-379107-028 106-646 106-640 107-594 107-594 108-055AG08-0353108-352
Marketing part number13N2227
39R8729
NoneNone25R806439R876525R806039R885043W433943W428043W429644E8767fc 357744X0411
FRU part number (adapter only)13N2233Not applicable (software only)25R807925R8076
ATB-200
25R807139R885243W428243W4295
ProcessorIntel IOP321Not applicableVitesse VSC7250Vitesse VSC7250LSI 1064EIntel Brockton IOP XScale processorLSI 1078eLSI 1078eLSI 1078eLSI 1078eLSI 1068eLSI 1064e
Useful linksDrivers Drivers Drivers Drivers Drivers Support Support Support
Drivers
Support
Drivers
Support
Drivers
Support
Drivers
User Guide
Drivers
Support
Drivers
Internal connectors101124 SATA x100022 mini-SAS SFF-80872 mini-SAS SFF-80871 mini-SAS SFF-8087
External connectors (std/max)001111 SAS x42 SAS x42 SAS x40*0000
Cable for extra external connectorNoneNoneNoneNoneNoneNoneNoneNoneNoneNoneNoneNoneNone
External connector typeNoneNoneNoneNoneSFF-8470 SFF-8088SFF-8470SFF-8088None*NoneNoneNoneNone
Cache256 MBNoneNone256 MB256 MBNone256 MB256 MB256 MB256 MB128MBNoneNone
Battery backup for cacheYesNoNoYesOptional
39R8812
NoneYesYes (Li-Ion)Yes (Li-Ion)
FRU 44W4283
Optional (NiMH)
43W4299
NoneNoneNone
SATA / SAS ports6 or 8Varies88242222221
SAS levelSAS
SATA 2
SAS
SATA 2
SAS
SATA 2
SAS
SATA 2
SAS
SATA 2
SAS
SATA 2
SAS
SATA 2
SAS 3Gbps
SATA 2
SAS 3Gbps
SATA 2
SAS 3Gbps
SATA 2
SAS 3Gbps
SATA 2
SAS 3Gbps
SATA 2
SAS 3Gbps
SATA 2
PCI or PCI-X or PCI ExpressPCI-X 1.0PCI-XPCIePCIePCIePCIePCIePCIePCIePCIePCIePCIePCIe
PCI bus speed133 MHzVariesx4x4x8x8x8x8x8x8x8x8x4
PCI bus width64-bitVariesNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicable
PCI bus voltage3.3VNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicableNot applicable
AutosyncYesYesYesYesYesYesYesYesYesYesYesYes
Active PCI support (hot-swap)NoNoNoNoNoNoNoNoNoNoNoYes
Clustering supportNoNoNoNoNoNoNoNoNoNoNo
Usable in a fault-tolerant pair NoNoNoNoNoNoNoNoNoNoNo
Data scrubbing ("Patrol read")YesNoYesYesYesNoYesYesYesYesYes
FlashcopyYesNoNoYesYesNoNoNoNoNoNo
CopybackYesNoNoYesYesNoNoNoNoNoNo
Maximum stripe size1024 KB64 KB1024 KB1024 KB1024 KB64 KB128 KB1024 KB1024 KB1024 KB
RAID-0 and RAID-1 supportYesYesYesYesYesYesYesYesYesYesYesYesYes
RAID-5 supportYesNoNoYesYesNoYesYesYesYesYesNoNo
RAID-1E supportYesNoNoYesYesYesNoNoNoNoYesNoYes
RAID-5E supportNoNoNoNoNoNoNoNoNoNoNoNoNo
RAID-5EE support (replaces 5E)YesNoNoNoNoNoNoNoNoNoNoNoNo
RAID-6YesNoNoYesYesNoNoYesYesYesYesNoNo
RAID-00 supportYesNoNoNoNoNoNoNoNoNoNoNoNo
RAID-10 supportYesYesYesYesYesNoYesYesYesYesYesNoNo
RAID-1E0 supportYesNoNoNoNoNoNoNoNoNoNoNoNo
RAID-50 supportYesNoNoNoYesNoYesYesYesYesYesNoNo
RAID-60 supportYesNoNoNoYesNoNoYesYesYesYesNoNo
Feature    SR 8iSR 8eSR 8k-lSR 8kSR-8sSAS HBAMegaRAIDSR-MR10MSR-MR10kSR-MR10iSR-MR10ilSR-BR10iSR-BR10il

* The ServeRAID-MR10k does not have an external connector, however the System x3850 M2 and x3950 M2 servers have a SFF-8088 external SAS port which the MR10k connects to.




Supported servers


The following tables lists which servers support each of the ServeRAID adapters. For the latest information about supported adapters, see ServerProven at http://www.ibm.com/servers/eserver/serverproven/compat/us/

Jump to



IBM Netfinity servers


Note: RAID controllers newer than the ones shown are not supported

ServerSRSR-IISR-3LSR-3HSR-3HBSR-4LSR-4LxSR-4MSR-4MxSR-4HSR-5iSR-6M
Netfinity 1000NoYesYesYesYesYesNoNoNoYesNoNo
Netfinity 3000NoYesYesYesYesYesNoNoNoNoNoNo
Netfinity 3500NoYesYesYesYesNoNoNoNoNoNoNo
Netfinity 3500 M20NoNoYesYesYesYesNoYesNoNoNoNo
Netfinity 4000RNoNoNoNoNoNoNoNoNoNoNoNo
Netfinity 4500RNoNoYesYesYesYesYesYesYesYesNoNo
Netfinity 5000NoYesYesYesYesYesNoYesNoYesNoNo
Netfinity 5100NoNoYesYesYesYesYesYesYesYesNoNo
Netfinity 5500 family*NoYesYesYesYesNoNoNoNoNoNoNo
Netfinity 5600NoNoYesYesYesYesYesYesYesYesNoNo
Netfinity 6000RNoNoYesYesYesYesYesYesYesYesNoNo
Netfinity 7000NoYesYesYesYesNoNoNoNoNoNoNo
Netfinity 7000 M10NoYesYesYesYesNoNoNoNoYesNoNo
Netfinity 7100NoNoYesYesYesYesYesYesYesYesNoNo
Netfinity 7600NoNoYesYesYesYesYesYesYesYesNoNo
Netfinity 8500RNoNoYesYesYesYesYesYesYesYesNoNo

* The Netfinity 5500, 5500 M10, and 5500 M20 have a ServeRAID-II controller built in on the server's planar. Two internal connectors: one to the internal hot-swap backplane and one that can be routed externally using an optional cable 03K9313.


IBM eServer xSeries servers


Note: RAID controllers newer than the ones shown in the table are not supported

ServerSRSR-IISR-3LSR-3HSR-3HBSR-4LSR-4LxSR-4MSR-4MxSR-4HSR-5iSR-6MSR-6iSR-6i+SR-7tSR-7eSR-7kSR-8iSR-8eSR-8k-lSR-8kSR-8s
xSeries 130 ValueNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 130 PerfNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 135 ValueNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 135 PerfNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 150NoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 200 (8478)NoNoNoNoNoYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 200 (8479)NoNoNoNoNoYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 205NoNoNoNoNoNoYesNoYesNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 206NoNoNoNoNoNoYesNoNoNoNoYesNoYesYesYesNoNoNoNoNoNo
xSeries 206mNoNoNoNoNoNoNoNoNoNoNoYesNoNoYesNoNoYesYesNoNoNo
xSeries 220 (8645)NoNoNoNoNoYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 220 (8646)NoNoNoNoNoYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 225 (8647)NoNoNoNoNoNoYesNoYesYesYesYesNoYesNoNoNoNoNoNoNoNo
xSeries 225 (8649)NoNoNoNoNoNoYesNoYesYesYesYesYesYesNoNoNoNoNoNoNoNo
xSeries 226NoNoNoNoNoNoNoNoNoNoNoYesNoYesYesYesNoNoNoNoNoNo
xSeries 230NoNoYesYesYesYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 232NoNoNoNoNoYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 235NoNoNoNoNoNoYesNoYesYesYesYesYesYesNoNoNoNoNoNoNoNo
xSeries 236NoNoNoNoNoNoNoNoNoNoNoYesNoNoNoYesYesNoNoNoNoNo
xSeries 240NoNoYesYesYesYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 250NoNoYesYesYesYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 255NoNoNoNoNoYesYesYesYesYesNoYesNoNoNoNoNoNoNoNoNoNo
xSeries 260NoNoNoNoNoNoNoNoNoNoNoYesNoNoNoNoNoYesNoNoNoNo
xSeries 300NoNoNoNoNoYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 305NoNoNoNoNoNoYesNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 306NoNoNoNoNoNoYesNoNoNoNoNoNoYesYesYesYesNoNoNoNoNo
xSeries 306mNoNoNoNoNoNoNoNoNoNoNoNoNoNoYesNoNoYesYesNoNoNo
ServerSRSR-IISR-3LSR-3HSR-3HBSR-4LSR-4LxSR-4MSR-4MxSR-4HSR-5iSR-6MSR-6iSR-6i+SR-7tSR-7eSR-7kSR-8iSR-8eSR 8k-lSR 8kSR-8s
xSeries 330 (8654)NoNoYesNoYesYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 330 (8674)NoNoYesNoNoYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 330 (8675)NoNoNoNoNoYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 335NoNoNoNoNoNoYesNoYesYesNoYesNoNoNoNoNoNoNoNoNoNo
xSeries 336NoNoNoNoNoNoNoNoNoNoNoYesNoYesYesNoNoNoNoNoNoNo
xSeries 340NoNoYesYesYesYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 342NoNoNoNoNoYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 343NoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 345NoNoNoNoNoNoYesNoYesNoYesYesYesYesNoNoNoNoNoNoNoNo
xSeries 346NoNoNoNoNoNoNoNoNoNoNoYesNoNoNoYesYesNoNoNoNoNo
xSeries 350NoNoYesYesYesYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 360NoNoNoNoNoYesYesYesYesYesNoYesNoNoNoNoNoNoNoNoNoNo
xSeries 365NoNoNoNoNoNoYesNoYesYesNoYesYesYesNoNoNoNoNoNoNoNo
xSeries 366NoNoNoNoNoNoNoNoNoNoNoYesNoNoNoNoNoYesNoNoNoNo
xSeries 370NoNoYesYesYesYesYesYesYesYesNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 380NoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo
xSeries 382NoNoNoNoNoNoYesNoYesNoNoYesNoNoNoNoNoNoNoNoNoNo
xSeries 440NoNoNoNoNoNoYesNoYesYesNoYesNoNoNoNoNoNoNoNoNoNo
xSeries 445NoNoNoNoNoNoYesNoYesYesNoYesNoNoNoNoNoNoNoNoNoNo
xSeries 450NoNoNoNoNoNoNoNoYesNoNoYesNoNoNoNoNoNoNoNoNoNo
xSeries 455NoNoNoNoNoNoNoNoYesNoNoYesNoNoNoNoNoNoNoNoNoNo
xSeries 460 & MXE-460NoNoNoNoNoNoNoNoNoNoNoYesNoNoNoNoNoYesNoNoNoNo
ServerSRSR-IISR-3LSR-3HSR-3HBSR-4LSR-4LxSR-4MSR-4MxSR-4HSR-5iSR-6MSR-6iSR-6i+SR-7tSR-7eSR-7kSR-8iSR-8eSR 8k-lSR 8kSR-8s


IBM eServer systems


Note: RAID controllers newer than the ones shown in the table are not supported

ServerSRSR-IISR-3LSR-3HSR-3HBSR-4LSR-4LxSR-4MSR-4MxSR-4HSR-5iSR-6MSR-6iSR-6i+SR-7tSR-7eSR-7kSR-8iSR-8eSR-8k-lSR-8kSR-8s
eServer 325NoNoNoNoNoNoYesNoNoNoNoYesNoNoNoNoNoNoNoNoNoNo
eServer 326NoNoNoNoNoNoYesNoNoNoNoYesNoNoYesNoNoNoNoNoNoNo
eServer 326mNoNoNoNoNoNoNoNoNoNoNoYesNoNoYesNoNoNoNoNoNoNo


IBM System x servers


Note: RAID controllers older than the ones shown in the table are not supported

ServerSR-6MSR-6iSR-6i+SR-7tSR-7eSR-7kSR-8iSR-8eSR-8k-lSR-8kSR-8sSAS HBAMegaRAID 8480SR-MR10MSR-MR10kSR-MR10iSR-MR10il§SR-BR10iSR-BR10il
System x3105NoNoNoYesNoNoNoNoNoNoNoYesNoNoNoNoNoNoNo
System x3200NoNoNoNoNoNoNoNoNoNoYesYesNoNoNoNoNoNoNo
System x3200 M2NoNoNoNoNoNoNoNoNoNoNoYesNoYesNoYesNoNoYes
System x3250 SATANoNoNoNoNoNoNoNoNoNoNoYesNoNoNoNoNoNoNo
System x3250 SAS/SATANoNoNoNoNoNoNoNoNoNoYesYesNoNoNoNoNoNoNo
System x3250 M2NoNoNoNoNoNoNoNoNoNoNoYesNoYesNoYes**NoNoYes
System x3350 NoNoNoNoNoNoNoNoNoNoNoYesNoYesNoYesNoNoYes
System x3400 SATANoNoNoNoNoNoNoYesNoYesYesYes*NoYesNoNoNoNoNo
System x3400 SAS/SATANoNoNoNoNoNoNoNoYesYesYesYes*NoYesNoNoNoNoNo
System x3455NoNoNoNoNoNoNoNoNoNoYesYesYesNoNoNoNoNoNo
System x3500NoNoNoNoNoNoNoNoNoYesYesYes*YesYesNoNoNoNoNo
System x3550 SATANoNoNoNoNoNoNoYesNoYesNoYes*YesYesNoNoNoNoNo
System x3550 SAS/SATANoNoNoNoNoNoNoNoYesYesNoYes*YesYesNoNoNoNoNo
System x3610NoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoYesNoNo
System x3650YesNoNoNoNoNoNoNoYesYesYesYes*YesYesNoNoNoNoNo
System x3650 TNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo
System x3655NoNoNoNoNoNoNoYesYesYesYesYes*YesYesNoNoNoNoNo
System x3755NoNoNoNoNoNoNoNoNoYesYesYes*YesYesNoNoNoNoNo
System x3800YesNoNoNoNoNoYesNoNoNoYesNoYesNoNoNoNoNoNo
System x3850YesNoNoNoNoNoYesNoNoNoYesNoYesNoNoNoNoNoNo
System x3850 M2NoNoNoNoNoNoNoNoNoNoNoYesNoYesYesNoNoNoNo
System x3950 / EYesNoNoNoNoNoYesNoNoNoNoNoNoNoNoNoNoNoNo
System x3950 M2NoNoNoNoNoNoNoNoNoNoNoYesNoYesYesNoNoNoNo
iDataPlex dx340NoNoNoNoNoNoNoNoNoNoNoNoNoNoNoYesNoYesNo
ServerSR-6MSR-6iSR-6i+SR-7tSR-7eSR-7kSR-8iSR-8eSR-8k-lSR-8kSR-8sSAS HBAMegaRAID 8480SR-MR10MSR-MR10kSR-MR10iSR-MR10ilSR-BR10iSR-BR10il

* The IBM SAS HBA Controller only supports tape attach for these systems. Connectivity to disks is not supported.
** The ServeRAID MR10i is only supported on models of the x3250 M2 with 2.5" drive bays. The MR10i is not supported on models with 3.5" drive bays.
§ The ServeRAID MR10il is available in specific countries only: China, Korea, Hong Kong, Taiwan, India and ASEAN nations.


IBM BladeCenter servers and expansion blades


Note: RAID controllers older than the ones shown in the table are not supported

ServerSR-6MSR-6iSR-6i+SR-7tSR-7eSR-7kSR-8iSR-8eSR-8k-lSR-8kSR-8sSAS HBAMegaRAID 8480SR-MR10MSR-MR10kSR-MR10iSR-MR10ilSR-BR10iSR-BR10il
BladeCenter HS20 8843Yes‡NoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo
BladeCenter HS21 8853Yes‡NoNoNoNoNoNoNoYes†Yes†NoNoNoNoNoNoNoNoNo
BladeCenter HS21 XM 7995Yes‡NoNoNoNoNoNoNoYes†Yes†NoNoNoNoNoNoNoNoNo
BladeCenter LS21 7971NoNoNoNoNoNoNoNoYes†Yes†NoNoNoNoNoNoNoNoNo
BladeCenter LS41 7972NoNoNoNoNoNoNoNoYes†Yes†NoNoNoNoNoNoNoNoNo
BladeCenter SIO 39R7563NoNoNoNoNoNoNoNoYesYesNoNoNoNoNoNoNoNoNo
BladeCenter PEU2 25K8373YesNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo


‡ With the addition of the BladeCenter PCI Expansion Unit 2 (PEU2), 25K8373
† With the addition of the BladeCenter Storage and I/O (SIO) Expansion Unit, 39R7563

Special Notices

This material has not been submitted to any formal IBM test and is published AS IS. It has not been the subject of rigorous review. IBM assumes no responsibility for its accuracy or completeness. The use of this information or the implementation of any of these techniques is a client responsibility and depends upon the client's ability to evaluate and integrate them into the client's operational environment.

Profile

Publish Date
27 September 2002

Last Update
20 October 2008


Rating:
(based on 49 reviews)


Author(s)

IBM Form Number
TIPS0054