The IBM Flex System x220 Compute Node is the next generation cost-optimized compute node designed for less demanding workloads and low-density virtualization. The x220 is efficient and equipped with flexible configuration options and advanced management to run a broad range of workloads.

Changes in the June 13 update:
* Add NVIDIA Tesla K40 for IBM Flex System PCIe Expansion Node
* Add IBM USB Memory Key for VMware ESXi 5.5
* Add 2.5" Enterprise Value SSDs

Contents


Table of contents


Introduction

The IBM® Flex System™ x220 Compute Node is the next generation cost-optimized compute node designed for less demanding workloads and low-density virtualization. The x220 is efficient and equipped with flexible configuration options and advanced management to run a broad range of workloads.

Suggested use: For clients looking to deploy an entry virtualization solution as part of a larger data center infrastructure.

The following figure shows the IBM Flex System x220 Compute Node.

The IBM Flex System x220 Compute Node
Figure 1. The IBM Flex System x220 Compute Node

Did you know

IBM Flex System is a new category of computing that integrates multiple server architectures, networking, storage, and system management capability into a single system that is easy to deploy and manage. IBM Flex System has full and built-in virtualization support of servers, storage, and networking to speed provisioning and increased resiliency. In addition, it supports open industry standards, such as operating systems, networking and storage fabrics, virtualization, and system management protocols, to easily fit within existing and future data center environments. IBM Flex System is scalable and extendable with multigenerational upgrades to protect and maximize IT investments.

Key features

The IBM Flex System x220 Compute Node is a high-availability, scalable compute node optimized to support the next-generation microprocessor technology. With a balance between cost and system features, the x220 is an ideal platform for general business workloads. This section describes the key features of the server.

Scalability and performance

The x220 offers numerous features to boost performance, improve scalability, and reduce costs:

  • The Intel Xeon processor E5-2400 product family improves productivity by offering affordable dual-socket system performance with eight-core processors with up to 2.3 GHz core speeds, up to 20 MB of L3 cache, and one QPI interconnect link of up to 8 GTps.
  • Up to two processors, 16 cores total, and 32 threads maximize the concurrent execution of multithreaded applications.
  • Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor Thermal Design Power (TDP).
  • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Intel Advanced Vector Extensions (AVT) improve floating point performance for compute-intensive technical and scientific applications compared to Intel Xeon 5600 series processors.
  • There are 12 DIMM sockets supporting low profile (LP) RDIMMs, UDIMMs and LRDIMMs, with a total capacity of up 384 GB using 32 GB LRDIMMs
  • Supports memory speeds of up to 1600 MHz to maximize memory performance.
  • Support for 1.8-inch solid-state drives to maximize I/O operations per second (IOPS) and significantly improve application performance.
  • Supports the Storage Expansion Node providing an additional 12 hot-swap 2.5-inch drive bays for local storage.
  • The theoretical maximum memory bandwidth of the Intel Xeon processor E5-2400 product family is 38.4 GBps, which is 20% more than in the previous generation of Intel Xeon 5600 processors.
  • The server offers PCI Express 3.0 I/O expansion capabilities that improve the theoretical maximum bandwidth by 60% (8 GTps per link) compared to the previous generation of PCI Express 2.0.
  • With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E5 family. This integration reduces I/O latency and increases overall system performance.
  • Support for high-bandwidth I/O adapters, up to two in each x220 Compute Node. Support for 10 Gb Ethernet, 16 Gb Fibre Channel, and FDR InfiniBand expansion cards.
  • Supports the PCIe Expansion Node for support for up to six additional I/O adapters.

Availability and serviceability

The x220 provides many features to simplify serviceability and increase system uptime:
  • Chipkill, memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
  • Tool-less cover removal provides easy access to upgrades and serviceable parts, such as processor, memory, and adapter cards.
  • Hot-swap drives supporting integrated RAID 1 redundancy for data protection and greater system uptime.
  • A light path diagnostics panel and individual light path LEDs lead the technician to failed (or failing) components. These features simplify servicing, speeds up problem resolution, and helps improve system availability.
  • Predictive Failure Analysis (PFA) detects when system components (such as processors, memory, and hard disk drives) operate outside of standard thresholds and generates proactive alerts in advance of possible failure, therefore increasing uptime.
  • Solid-state drives (SSDs), which offer significantly better reliability than traditional mechanical HDDs for greater uptime.
  • A built-in Integrated Management Module II (IMM2) continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
  • Built-in diagnostics using Dynamic Systems Analysis (DSA) Preboot speeds up troubleshooting tasks to reduce service time.
  • Three-year customer replaceable unit and on-site limited warranty, next business day 9x5. Optional service upgrades are available.

Manageability and security

Powerful systems management features simplify local and remote management of the x220:
  • The server includes an Integrated Management Module II (IMM2) to monitor server availability and perform remote management.
  • An integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
  • Integrated Trusted Platform Module (TPM) V 1.2 support enables advanced cryptographic functionality, such as digital signatures and remote attestation.
  • Industry-standard AES NI support for faster, stronger encryption.
  • Integrates with the IBM® Flex System™ Manager for proactive systems management. It offers comprehensive systems management for the entire IBM Flex System platform, increasing uptime, reducing costs, and improving productivity through advanced server management capabilities.
  • IBM Fabric Manager simplifies the deployment of infrastructure connections by managing network and storage address assignments.
  • Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space protected from all other software running on a system.

Energy efficiency

The x220 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to a green environment:
  • Component-sharing design of the IBM Flex System chassis provides ultimate power and cooling savings.
  • The Intel Xeon processor E5-2400 product family offers better performance over the previous generation while fitting into the same TDP limits.
  • Intel Intelligent Power Capability powers individual processor elements on and off as needed, to reduce power draw.
  • Low-voltage Intel Xeon processors draw less energy to satisfy demands of power and thermally constrained data centers and telecommunication environments.
  • Low-voltage 1.35 V DDR3 memory RDIMMs consume 15% less energy than 1.5 V DDR3 RDIMMs.
  • Solid-state drives (SSDs) consume as much as 80% less power than traditional spinning 2.5-inch HDDs.
  • The server uses hexagonal ventilation holes, a part of IBM Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, providing more efficient airflow through the system.

Locations of key components and connectors

The following figure shows the front of the server.

Front view of the IBM Flex System x220 Compute Node
Figure 2. Front view of the IBM Flex System x220 Compute Node

The following figure shows the locations of key components inside the server.

Inside view of the IBM Flex System x220 Compute Node
Figure 3. Inside view of the IBM Flex System x220 Compute Node

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications

ComponentsSpecification
Form factorStandard-width compute node.
Chassis supportIBM Flex System Enterprise Chassis.
ProcessorUp to two Intel Xeon Processor E5-2400 product family processors with eight-core (up to 2.3 GHz), six-core (up to 2.4 GHz), or quad-core (up to 2.2 GHz), one QPI link running at 8.0 GTps, L3 cache up to 20 MB, and memory speeds up to 1600 MHz. The server also supports one Intel Pentium Processor 1400 product family processor with two cores, up to 2.8 GHz, 5 MB L3 cache, and 1066 MHz memory speeds.
ChipsetIntel C600 series.
MemoryUp to 12 DIMM sockets (six DIMMs per processor) using Low Profile (LP) DDR3 DIMMs. RDIMMs, UDIMMs and LRDIMMs are supported. 1.5 V and low-voltage 1.35 V DIMMs are supported. Support for up to 1600 MHz memory speed, depending on the processor. Three memory channels per processor (two DIMMs per channel). Supports two DIMMs per channel operating at 1600 MHz (2 DPC @ 1600 MHz) with single and dual rank RDIMMs.
Memory maximumsWith LRDIMMs: Up to 384 GB with 12x 32 GB LRDIMMs and two E5-2400 processors.
With RDIMMs: Up to 192 GB with 12x 16 GB RDIMMs and two E5-2400 processors.
With UDIMMs: Up to 48 GB with 12x 4 GB UDIMMs and two E5-2400 processors.
Half of these maximums and DIMMs counts with one processor installed.
Memory protectionECC, Chipkill (for x4-based memory DIMMs), and optional memory mirroring and memory rank sparing.
Disk drive baysTwo 2.5-inch hot-swap SAS/SATA drive bays supporting SAS, SATA, and SSD drives. Optional support for up to eight 1.8-inch SSDs. Onboard ServeRAID C105 supports SATA drives only. Up to 12 additional 2.5-inch drive bays with the optional Storage Expansion Node.
Maximum internal storage With two 2.5-inch hot-swap drives: Up to 2 TB with 1 TB 2.5-inch NL SAS HDDs, up to 2.4 TB with 1.2 TB 2.5-inch SAS HDDs, up to 2 TB with 1 TB 2.5-inch NL SATA HDDs, or up to 1 TB with 512 GB 2.5-inch SATA SSDs. An intermix of SAS and SATA HDDs and SSDs is supported. With 1.8-inch SSDs and ServeRAID M5115 RAID adapter, you can have up to 4 TB with eight 512 GB 1.8-inch SSDs.
RAID supportSoftware RAID 0 and 1 with integrated LSI-based 3 Gbps ServeRAID C105 controller; supports SATA drives only. Non-RAID not supported.
Optional ServeRAID H1135 RAID adapter with LSI SAS2004 controller, supports SAS/SATA drives with hardware-based RAID 0 and 1. An H1135 adapter is installed in a dedicated PCIe 2.0 x4 connector and does not use either I/O adapter slot.
Optional ServeRAID M5115 RAID adapter with RAID 0, 1, 10, 5, 50 support and 1 GB cache. M5115 uses the I/O adapter slot 1. Can be installed in all models, including models with embedded a 1 GbE with Fabric connector. Supports up to eight 1.8-inch SSD with expansion kits. Optional flash-backup for cache, RAID 6/60, and SSD performance enabler.
Network interfacesSome models (see Table 2): Embedded dual-port Broadcom BCM5718 Ethernet Controller that supports Wake on LAN and Serial over LAN, IPv6. TCP/IP Offload Engine (TOE) not supported. Routes to chassis I/O module bays 1 and 2 through a Fabric Connector to the chassis midplane. The Fabric Connector precludes the use of I/O adapter slot 1, with the exception that the M5115 can be installed in slot 1 while the Fabric Connector is installed. Remaining models: No network interface standard; optional 1 Gb or 10 Gb Ethernet adapters.
PCI Expansion slotsTwo connectors for I/O adapters; each connector has PCIe x8+x4 interfaces.
Includes an Expansion Connector (PCIe 3.0 x16) to connect an expansion node such as the PCIe Expansion Node
Dedicated PCIe 2.0 x4 interface for ServeRAID H1135 adapter only.
PCIe Expansion Node supports two full-height PCIe adapters, two low-profile PCIe adapters and two Flex System I/O adapters.
PortsUSB ports: One external and two internal ports for an embedded hypervisor. A console breakout cable port on the front of the server provides local KVM and serial ports (cable standard with chassis; additional cables optional).
Systems management UEFI, IBM Integrated Management Module 2 (IMM2) with Renesas SH7757 controller, Predictive Failure Analysis, light path diagnostics panel, automatic server restart, and remote presence. Support for IBM Flex System Manager, IBM Systems Director, and IBM ServerGuide.
Security featuresPower-on password, administrator's password, and Trusted Platform Module V1.2.
VideoMatrox G200eR2 video core with 16 MB video memory integrated into the IMM2. Maximum resolution is 1600x1200 at 75 Hz with 16 M colors.
Limited warranty Three-year customer-replaceable unit and on-site limited warranty with 9x5/NBD.
Operating systems supported Microsoft Windows Server 2008 R2, Red Hat Enterprise Linux 5 and 6, SUSE Linux Enterprise Server 10 and 11, VMware ESX 4.1 and 5. See "Supported operating systems" for details.
Service and supportOptional service upgrades are available through IBM ServicePac® offerings: 4-hour or 2-hour response time, 8-hour fix time, 1-year or 2-year warranty extension, remote technical support for IBM hardware and selected IBM and OEM software.
DimensionsWidth: 217 mm (8.6 in.), height: 56 mm (2.2 in.), depth: 492 mm (19.4 in.)
WeightMaximum configuration: 6.4 kg (14.11 lb).

The x220 servers are shipped with the following items:
  • Statement of Limited Warranty
  • Important Notices
  • Documentation CD that contains the Installation and User's Guide

Standard models

The following table lists the standard models.

Table 2. Standard models

ModelIntel Processor**
E5-2400: 2 maximum
Pentium 1400: 1 max
MemoryRAIDDisk
bays†
Disks1 GbE
Embed‡
I/O slots
(used/
max)
7906-
A2x
1x Intel Pentium 1403 2C
2.6 GHz 5 MB 1066 MHz 80W
1x 4GB 1066 MHz*
UDIMM
C1052x 2.5-inch
hot-swap
OpenStandard1 / 2‡
7906-
B2x
1x Intel Xeon E5-2430L 6C
2.0 GHz 15 MB 1333 MHz 60W
1x 4GB 1333 MHz
UDIMM
C1052x 2.5-inch
hot-swap
OpenStandard1 / 2‡
7906-
C2x
1x Intel Xeon E5-2403 4C
1.8 GHz 10 MB 1066 MHz 80W
1x 4GB 1066 MHz*
RDIMM
C1052x 2.5-inch
hot-swap
OpenStandard1 / 2‡
7906-
D2x
1x Intel Xeon E5-2420 6C
1.9 GHz 15 MB 1333 MHz 95W
1x 4GB 1333 MHz
RDIMM
C1052x 2.5-inch
hot-swap
OpenStandard1 / 2‡
7906-
F2x
1x Intel Xeon E5-2418L 4C
2.0GHz 10MB 1333MHz 50W
1x 4GB 1333 MHz
RDIMM
C1052x 2.5-inch
hot-swap
OpenStandard1 / 2‡
7906-
G2x
1x Intel Xeon E5-2430 6C
2.2 GHz 15 MB 1333 MHz 95W
1x 4GB 1333 MHz
RDIMM
C1052x 2.5-inch
hot-swap
OpenNo0 / 2
7906-
G4x
1x Intel Xeon E5-2430 6C
2.2 GHz 15 MB 1333 MHz 95W
1x 4GB 1333 MHz
RDIMM
C1052x 2.5-inch
hot-swap
OpenStandard1 / 2‡
7906-
H2x
1x Intel Xeon E5-2440 6C
2.4 GHz 15 MB 1333 MHz 95W
1x 4GB 1333 MHz
RDIMM
C1052x 2.5-inch
hot-swap
OpenStandard1 / 2‡
7906-
J2x
1x Intel Xeon E5-2450 8C
2.1 GHz 20 MB 1600 MHz 95W
1x 4GB 1333 MHz*
RDIMM
C1052x 2.5-inch
hot-swap
OpenNo0 / 2
7906-
L2x
1x Intel Xeon E5-2470 8C
2.3 GHz 20 MB 1600 MHz 95W
1x 4GB 1333 MHz*
RDIMM
C1052x 2.5-inch
hot-swap
OpenNo0 / 2
7906-
DBx§
2x Intel Xeon E5-2420 6C
1.9 GHz 15 MB 1333 MHz 95W
2x 4GB 1333 MHz
RDIMM
C10514x 2.5-inch
hot-swap with Storage
Expansion Node§
OpenStandard1 / 2‡
** Processor details: Processor quantity and model, cores, core speed, L3 cache, memory speed, and power consumption.
* For model A2x and C2x, the standard DIMM is rated at 1333 MHz, but operates at up to 1066 MHz to match the processor memory speed. Conversely, for models J2x and L2x, the processor memory speed is rated at 1600 MHz, but operates up to 1333 MHz to match the rated speed of the installed DIMM. Actual memory speed maximums depend on several factors, as described in "Memory options".
† The 2.5-inch drive bays can be replaced and expanded with a new backplane and a ServeRAID M5115 RAID controller to support up to eight 1.8-inch solid-state drives (SSDs).
‡ These models include an Embedded 1 Gb Ethernet controller. Connections are routed to the chassis midplane using a Fabric Connector. The Fabric Connector precludes the use of an I/O adapter in I/O connector 1 (with the exception of the ServeRAID M5115 RAID controller).
§ Model DBx is optimized as a Network Attached Storage (NAS) offering and includes the IBM Flex System Storage Expansion Node (68Y8588) as standard

Model 7906-DBx is a new Network Attached Storage (NAS) optimized model that includes the x220 compute node and the Flex System Storage Expansion Node connected together as a single unit at the factory. This single model number enables a simpler acquisition for both business partners and direct sales. The combination of the x220 compute node and the storage node is certified with Windows Storage Server 2012 meaning that this configuration is an excellent foundation for a low cost NAS solution. Windows Storage Server 2012 is available via the IBM Reseller Option Kit (ROK) program using part number 00Y6302. Model DBx does not include drives giving you maximum flexibility when it comes to selecting drives, either SAS or SATA disk drives or high-performance solid-state drives.

Chassis support

The x220 is supported in the IBM Flex System Enterprise Chassis. Up to 14 x220 Compute Nodes can be installed in the chassis (10U of rack space).

Processor options

The x220 supports the processor options listed in the following table. The server supports one or two Intel Xeon E5-2400 processors, but the server supports only one Intel Pentium 1403 or 1407 processor or E5-1410 processor. The table also shows which server models have each processor standard. If no corresponding where used model for a particular processor is listed, then this processor is available only through configure-to-order (CTO) process.

Table 3. Processor options

Part
number
Feature code*Intel Xeon processor descriptionModels
where used
Intel Pentium processors
NoneA1VZ / NoneIntel Pentium 1403 2C 2.6 GHz 5 MB 1066 MHz 80 W A2x
None*A1W0 / NoneIntel Pentium 1407 2C 2.8 GHz 5 MB 1066 MHz 80 W-
Intel Xeon processors
None*A3C4 / NoneIntel Xeon E5-1410 4C 2.8GHz 10MB 1333MHz 80W-
90Y4801A1VY / A1WCIntel Xeon E5-2403 4C 1.8 GHz 10 MB 1066 MHz 80 W C2x
90Y4800A1VX / A1WBIntel Xeon E5-2407 4C 2.2 GHz 10 MB 1066 MHz 80 W-
90Y4799A1VW / A1WAIntel Xeon E5-2420 6C 1.9 GHz 15 MB 1333 MHz 95 W D2x, DBx
90Y4797A1VU / A1W8Intel Xeon E5-2430 6C 2.2 GHz 15 MB 1333 MHz 95 W G2x, G4x
90Y4796A1VT / A1W7Intel Xeon E5-2440 6C 2.4 GHz 15 MB 1333 MHz 95 W H2x
90Y4795A1VS / A1W6Intel Xeon E5-2450 8C 2.1 GHz 20 MB 1600 MHz 95 W J2x
90Y4793A1VQ / A1W4Intel Xeon E5-2470 8C 2.3 GHz 20 MB 1600 MHz 95 W L2x
Intel Xeon processors - Low power
00D9528A3C7 / A3CAIntel Xeon E5-2418L 4C 2.0GHz 10MB 1333MHz 50WF2x
00D9527A3C6 / A3C9Intel Xeon E5-2428L 6C 1.8GHz 15MB 1333MHz 60W-
90Y4805A1W2 / A1WEIntel Xeon E5-2430L 6C 2.0 GHz 15 MB 1333 MHz 60 WB2x
00D9526A3C5 / A3C8Intel Xeon E5-2448L 8C 1.8GHz 20MB 1600MHz 70W-
90Y4804A1W1 / A1WDIntel Xeon E5-2450L 8C 1.8 GHz 20 MB 1600 MHz 70 W-
* The Intel Pentium 1407 and Intel Xeon E5-1410 are available through CTO or special bid only.
** The first feature code is for processor 1 and second feature code is for processor 2

Memory options

IBM DDR3 memory is compatibility tested and tuned for optimal performance and throughput. IBM memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime. From a service and support standpoint, IBM memory automatically assumes the IBM system warranty, and IBM provides service and support worldwide.

The x220 supports Low Profile (LP) DDR3 memory RDIMMs, UDIMMs and LRDIMMs. The server supports up to six DIMMs when one processor is installed and up to 12 DIMMs when two processors are installed. Each processor has three memory channels, and there are two DIMMs per channel.

The following rules apply when selecting the memory configuration:

  • Mixing 1.5 V and 1.35 V DIMMs in the same server is supported, but all DIMMs operate at 1.5 V.
  • The maximum number of ranks supported per channel is eight.
  • The maximum quantity of DIMMs that can be installed in the server depends on the number of processors, as shown in the "Max. qty supported" row in the following table.
  • All DIMMs in all processor memory channels operate at the same speed, which is determined as the lowest value of:
    • Memory speed supported by a specific processor.
    • Lowest maximum operating speed for the selected memory configuration that depends on rated speed, as shown under the "Max. operating speed" section in the following table. The shaded cells indicate that the speed indicated is the maximum that the DIMM allows.

The following table shows the maximum memory speeds that are achievable based on the installed DIMMs and the number of DIMMs per channel. The table also shows maximum memory capacity at any speed supported by the DIMM and maximum memory capacity at rated DIMM speed. In the table, cells highlighted with a grey background indicate when the specific combination of DIMM voltage and number of DIMMs per channel still allows the DIMMs to operate at rated speed.

Table 4. Maximum memory speeds (Part 1: UDIMMs and LRDIMMs)
Spec
UDIMMs
LRDIMMs
Rank
Single rank
Dual rank
Quad rank
Part numbers
49Y1403 (2 GB)
49Y1404 (4 GB)
90Y3105 (32 GB)
Rated speed
1333 MHz
1333 MHz
1333 MHz
Rated voltage
1.35 V
1.35 V
1.35 V
Operating
voltage
1.35 V
1.5 V
1.35 V
1.5 V
1.35 V
1.5 V
Max quantity*
12
12
12
12
12
12
Largest DIMM
2 GB
2 GB
4 GB
4 GB
32 GB
32 GB
Max memory
capacity
24 GB
24 GB
48 GB
48 GB
384 GB
384 GB
Max memory
at rated speed
12 GB
12 GB
24 GB
24 GB
N/A
192 GB
Maximum operating speed (MHz)
1 DIMM
per channel
1333 MHz
1333 MHz
1333 MHz
1333 MHz
1066 MHz
1333 MHz
2 DIMMs
per channel
1066 MHz
1066 MHz
1066 MHz
1066 MHz
1066 MHz
1066 MHz
* The maximum quantity supported is shown for two processors installed. When one processor is installed, the maximum quantity supported is half of that shown.

Table 4. Maximum memory speeds (Part 2: RDIMMs)
Spec
RDIMMs
Rank
Single rank
Dual rank
Quad rank
Part numbers
49Y1406 (4 GB)
49Y1559 (4 GB)
49Y1407 (4 GB)
49Y1397 (8 GB)
49Y1563 (16 GB)
90Y3178 (4 GB)
90Y3109 (8 GB)
00D4968 (16 GB)
49Y1400 (16 GB)
Rated speed
1333 MHz
1600 MHz
1333 MHz
1600 MHz
1066 MHz
Rated voltage
1.35 V
1.5 V
1.35 V
1.5 V
1.35 V
Operating
voltage
1.35 V
1.5 V
1.5 V
1.35 V
1.5 V
1.5 V
1.35 V
1.5 V
Max quantity*
12
12
12
12
12
12
12
12
Largest DIMM
4 GB
4 GB
4 GB
16 GB
16 GB
16 GB
16 GB
16 GB
Max memory
capacity
48 GB
48 GB
48 GB
192 GB
192 GB
192 GB
192 GB
192 GB
Max memory
at rated speed
48 GB
48 GB
48 GB
129 GB
192 GB
192 GB
N/A
N/A
Maximum operating speed (MHz)
1 DIMM
per channel
1333 MHz
1333 MHz
1600 MHz
1333 MHz
1333 MHz
1600 MHz
800 MHz
800 MHz
2 DIMMs
per channel
1333 MHz
1333 MHz
1600 MHz
1333 MHz
1333 MHz
1600 MHz
800 MHz
800 MHz
* The maximum quantity supported is shown for two processors installed. When one processor is installed, the maximum quantity supported is half of that shown.


The following memory protection technologies are supported:
  • ECC
  • Chipkill (for x4-based memory DIMMs; look for "x4" in the DIMM description)
  • Memory mirroring
  • Memory sparing

If memory mirroring is used, then DIMMs must be installed in pairs (minimum of one pair per processor), and both DIMMs in a pair must be identical in type and size.

If memory rank sparing is used, then a minimum of one quad-rank DIMM or two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need to be identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs installed.

The following table lists the memory options available for the x220 server. DIMMs can be installed one at a time, but for performance reasons, install them in sets of three (one for each of the three memory channels).

Table 5. Memory options for the x220
Part numberFeature codeDescriptionModels
where used
Registered DIMMs (RDIMMs) - 1333 MHz and 1066 MHz
49Y140689414 GB (1x 4 GB, 1Rx4, 1.35 V) PC3L-10600 CL9 ECC DDR3 1333 MHz LP RDIMMJ2x, L2x, DBx
49Y140789424 GB (1x 4 GB, 2Rx8, 1.35 V) PC3L-10600 CL9  ECC DDR3 1333 MHz LP RDIMMC2x, D2x, F2x, G2x, G4x, H2x
49Y139789238 GB (1x 8 GB, 2Rx4, 1.35 V) PC3L-10600 CL9 ECC DDR3 1333 MHz LP RDIMM-
49Y1563A1QT16 GB (1x16GB, 2Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 1333MHz LP RDIMM-
49Y1400893916 GB (1x 16 GB, 4Rx4, 1.35 V) PC3L-8500 CL7 ECC DDR3 1066 MHz LP RDIMM-
Registered DIMMs (RDIMMs) - 1600 MHz
49Y1559A28Z4 GB (1x4GB, 1Rx4, 1.5V) PC3-12800 CL11 ECC DDR3 1600MHz LP RDIMM-
90Y3178A24L4 GB (1x4GB, 2Rx8, 1.5V) PC3-12800 CL11 ECC DDR3 1600MHz LP RDIMM-
90Y3109A2928 GB (1x 8 GB, 2Rx4, 1.5 V) PC3-12800 CL11 ECC DDR3 1600 MHz LP RDIMM-
00D4968A2U516 GB (1x16GB, 2Rx4, 1.5V) PC3-12800 CL11 ECC DDR3 1600MHz LP RDIMM-
Unbuffered DIMMs (UDIMMs)
49Y1403A0QS2 GB (1x 2 GB, 1Rx8, 1.35 V) PC3L-10600 ECC DDR3 1333 MHz LP UDIMMA2x, B2x
49Y140486484 GB (1x 4 GB, 2Rx8, 1.35 V) PC3L-10600 CL9 ECC DDR3 1333 MHz LP UDIMM-
Load-reduced DIMMs (LRDIMMs)
90Y3105A29132GB (1x32GB, 4Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 1333MHz LP LRDIMM-

RAID controllers for internal storage

The x220 server has two 2.5-inch hot-swap drive bays accessible from the front of the blade server (Figure 2). The server optionally supports 1.8-inch solid-state drives, as described later in this section.

The x220 supports three disk controllers:

  • ServeRAID C105: An onboard SATA controller with software RAID capabilities
  • ServeRAID H1135: An entry level hardware RAID controller
  • ServeRAID M5115: An advanced RAID controller with cache, backup, and RAID options

These three controllers are mutually exclusive. The following table lists the ordering information.

Table 6. Internal storage controller ordering information
Part numberFeature
code
DescriptionMaximum
supported
StandardNoneServeRAID C1051
90Y4750A1XJServeRAID H1135 Controller for IBM Flex System and IBM BladeCenter®1
90Y4390A2XWServeRAID M5115 SAS/SATA Controller 1

ServeRAID C105 controller

On standard models, the two 2.5-inch drive bays are connected to a ServeRAID C105 onboard SATA controller with software RAID capabilities. The C105 functionality is embedded in the Intel C600 chipset.

The C105 has the following features:
  • Support for SATA drives (SAS is not supported)
  • Support for RAID 0 and RAID 1 (non-RAID is not supported)
  • 6 Gbps throughput per port
  • Support for up to two volumes
  • Support for virtual drive sizes greater than 2 TB
  • Fixed stripe unit size of 64 KB
  • Support for MegaRAID Storage Manager management software

Note: There is no native (in-box) driver for Windows and Linux; the drivers must be downloaded separately. There is no support for VMware, Hyper-V, Xen, or solid-state drives (SSD).

ServeRAID H1135

The x220 also supports an entry level hardware RAID solution with the addition of the ServeRAID H1135 Controller for IBM Flex System and BladeCenter. The H1135 is installed in a dedicated slot at the front of the server (see Figure 3). When the H1135 adapter is installed, the C105 controller is disabled.

The H1135 has the following features:
  • Based on the LSI SAS2004 6 Gbps SAS 4-port controller
  • PCIe 2.0 x4 host interface
  • CIOv form factor (supported in the x220 and BladeCenter HS23E)
  • Support for SAS, SATA, and SSD drives
  • Support for RAID 0, RAID 1, and non-RAID
  • 6 Gbps throughput per port
  • Support for up to two volumes
  • Fixed stripe size of 64 KB
  • Native driver support in Windows, Linux, and VMware
  • S.M.A.R.T. support
  • Support for MegaRAID Storage Manager management software

ServeRAID M5115

The ServeRAID M5115 SAS/SATA Controller (90Y4390) is an advanced RAID controller supporting RAID 0, 1, 10, 5, 50, and optional 6 and 60. It includes 1 GB of cache, which can be backed up to flash memory when attached to an optional supercapacitor. The M5115 attaches to the I/O adapter 1 connector and can be attached even if the Fabric Connector is installed (used to route the Embedded Gb Ethernet to chassis bays 1 and 2). The ServeRAID M5115 cannot be installed if an adapter is installed in I/O adapter slot 1. When the M5115 adapter is installed, the C105 controller is disabled.

The ServeRAID M5115 supports combinations of 2.5-inch drives and 1.8-inch solid-state drives:
  • Up to two 2.5-inch drives only
  • Up to four 1.8-inch drives only
  • Up to two 2.5-inch drives, plus up to four 1.8-inch solid-state drives
  • Up to eight 1.8-inch solid-state drives

We describe these configurations in the following section.

The ServeRAID M5115 controller has the following specifications:
  • Eight internal 6 Gbps SAS/SATA ports.
  • PCI Express 3.0 x8 host interface.
  • 6 Gbps throughput per port.
  • 800 MHz dual-core IBM PowerPC® processor with an LSI SAS2208 6 Gbps RAID on Chip (ROC) controller.
  • Support for RAID levels 0, 1, 10, 5, 50 standard; support for RAID 6 and 60 with optional upgrade using 90Y4411.
  • Onboard 1 GB data cache (DDR3 running at 1333 MHz) with optional flash backup (MegaRAID CacheVault technology) as part of the Enablement Kit 90Y4424.
  • Support for SAS and SATA HDDs and SSDs.
  • Support for intermixing SAS and SATA HDDs and SSDs. Mixing different types of drives in the same array (drive group) is not recommended.
  • Support for self-encrypting drives (SEDs) with MegaRAID SafeStore.
  • Optional support for SSD performance acceleration with MegaRAID FastPath and SSD caching with MegaRAID CacheCade Pro 2.0 (90Y4447).
  • Support for up to 64 virtual drives, up to 128 drive groups, up to 16 virtual drives per one drive group, and up to 32 physical drives per one drive group.
  • Support for logical unit number (LUN) sizes up to 64 TB.
  • Configurable stripe size up to 1 MB.
  • Compliant with Disk Data Format (DDF) configuration on disk (COD).
  • S.M.A.R.T. support.
  • MegaRAID Storage Manager management software.


ServeRAID M5115 configurations and options

The x220 with the addition of the M5115 controller supports 2.5-inch drives or 1.8-inch solid-state drives or combinations of the two.

At least one hardware kit is required with the ServeRAID M5115 controller, and there are three hardware kits that are supported that enable specific drive support:
  • ServeRAID M5100 Series Enablement Kit for IBM Flex System x220 (90Y4424) enables support for up to two 2.5-inch HDDs or SSDs in the hot-swap bays in the front of the server. It includes a CacheVault unit, which enables MegaRAID CacheVault flash cache protection. This enablement kit replaces the standard two-bay backplane (which is attached through the planar to an onboard controller) with a new backplane that attaches to an included flex cable to the M5115 controller. It also includes an air baffle, which also serves as an attachment for the CacheVault unit.

    MegaRAID CacheVault flash cache protection uses NAND flash memory powered by a supercapacitor to protect data stored in the controller cache. This module eliminates the need for a lithium-ion battery commonly used to protect DRAM cache memory on PCI RAID controllers. To avoid the possibility of data loss or corruption during a power or server failure, CacheVault technology transfers the contents of the DRAM cache to NAND flash using power from the supercapacitor. After the power is restored to the RAID controller, the saved data is transferred from the NAND flash back to the DRAM cache, which can then be flushed to disk.

    Tip: The Enablement Kit is only required if 2.5-inch drives are to be used. If you plan to install four or eight 1.8-inch SSDs only, then this kit is not required.

  • ServeRAID M5100 Series IBM Flash Kit for IBM Flex System x220 (90Y4425) enables support for up to four 1.8-inch SSDs. This kit replaces the standard two-bay backplane with a four-bay SSD backplane that attaches to an included flex cable to the M5115 controller. Because only SSDs are supported, a CacheVault unit is not required, and therefore this kit does not have a supercapacitor.
  • ServeRAID M5100 Series SSD Expansion Kit for IBM Flex System x220 (90Y4426) enables support for up to four internal 1.8-inch SSDs. This kit includes two air baffles, left and right, which can attach two 1.8-inch SSD attachment locations and flex cables for attachment to up to four 1.8-inch SSDs.

The following table shows the kits required for each combination of drives. For example, if you plan to install eight 1.8-inch SSDs, then you need the M5115 controller, the Flash kit, and the SSD Expansion kit.

Table 7. ServeRAID M5115 hardware kits
Desired drive support
Components required
Maximum
number of
2.5-inch drives
Maximum
number of
1.8-inch SSDs
ServeRAID
M5115
90Y4390
Enablement Kit
90Y4424
Flash Kit
90Y4425
SSD
Expansion Kit
90Y4426
20
=>
RequiredRequired
04 (front)
=>
RequiredRequired
24 (internal)
=>
RequiredRequiredRequired
08 (both)
=>
RequiredRequiredRequired

The following figure shows how the ServeRAID M5115 and the Enablement Kit are installed in the server to support two 2.5-inch drives with MegaRAID CacheVault flash cache protection (row 1 of the preceding table).

The ServeRAID M5115 and the Enablement Kit installed
Figure 4. The ServeRAID M5115 and the Enablement Kit installed

The following figure shows how the ServeRAID M5115 and Flash and SSD Expansion Kits are installed in the server to support eight 1.8-inch solid-state drives (row 4 of the preceding table).

ServeRAID M5115 with Flash and SSD Expansion Kits installed
Figure 5. ServeRAID M5115 with Flash and SSD Expansion Kits installed

The eight SSDs are installed in the following locations:
  • Four in the front of the system in place of the two 2.5-inch drive bays
  • Two in a tray above the memory banks for processor 1
  • Two in a tray above the memory banks for processor 2

Optional add-ons to the ServeRAID M5115 controller are RAID 6 support, SSD performance accelerator, and SSD caching enabler. The feature upgrades are as listed in the following table. These are all Feature on Demand (FoD) license upgrades.

Table 8. Supported upgrade features
Part numberFeature
code
DescriptionMaximum
supported
90Y4410A2Y1ServeRAID M5100 Series RAID 6 Upgrade for IBM Flex System1
90Y4412A2Y2ServeRAID M5100 Series Performance Upgrade for IBM Flex System
(MegaRAID FastPath)
1
90Y4447A36GServeRAID M5100 Series SSD Caching Enabler for IBM Flex System
(MegaRAID CacheCade Pro 2.0)
1

These features are described as follows:
  • RAID 6 Upgrade (90Y4410)

    Adds support for RAID 6 and RAID 60. This is a Feature on Demand license.

  • Performance Upgrade (90Y4412)

    The Performance Upgrade for IBM Flex System (implemented using the LSI MegaRAID FastPath software) provides high-performance I/O acceleration for SSD-based virtual drives by using an extremely low-latency I/O path to increase the maximum I/O per second (IOPS) capability of the controller. This feature boosts the performance of applications with a highly random data storage access pattern, such as transactional databases. Part number 90Y4412 is a Feature on Demand license.

  • SSD Caching Enabler for traditional hard drives (90Y4447)

    The SSD Caching Enabler for IBM Flex System (implemented using the LSI MegaRAID CacheCade Pro 2.0) is designed to accelerate the performance of hard disk drive (HDD) arrays with only an incremental investment in solid-state drive (SSD) technology. The feature enables the SSDs to be configured as a dedicated cache to help maximize the I/O performance for transaction-intensive applications, such as databases and web serving. The feature tracks data storage access patterns and identifies the most frequently accessed data. The hot data is then automatically stored on the SSDs that are assigned as a dedicated cache pool on the ServeRAID controller. Part number 90Y4447 is a Feature on Demand license. This feature requires that at least one SSD drive be installed.

    Note: Not all SSDs support SSD Caching Enabler (CacheCade) feature. See http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5094754 for details.


Internal drive options

The 1.8-inch solid-state drives supported with the ServeRAID M5115 are listed in the following table.

Table 9. Supported 1.8-inch solid-state drives

Part numberFeature
code
DescriptionMaximum
supported
Enterprise SSDs
41Y8371A4FTS3700 400GB SATA 1.8" MLC Enterprise SSD8
41Y8366A4FSS3700 200GB SATA 1.8" MLC Enterprise SSD8
49Y6124A3APIBM 400GB SATA 1.8" MLC Enterprise SSD8
49Y6119A3ANIBM 200GB SATA 1.8" MLC Enterprise SSD8
00W1120A3HQIBM 100GB SATA 1.8" MLC Enterprise SSD8
43W77465420IBM 200 GB SATA 1.8-inch MLC SSD8
43W77265428IBM 50 GB SATA 1.8-inch MLC SSD8
Enterprise Value SSDs
49Y5993A3ARIBM 512 GB SATA 1.8-inch MLC Enterprise Value SSD8
49Y5834A3AQIBM 64 GB SATA 1.8-inch MLC Enterprise Value SSD8
00W1222A3TGIBM 128GB SATA 1.8" MLC Enterprise Value SSD8
00W1227A3THIBM 256GB SATA 1.8" MLC Enterprise Value SSD8
00AJ040A4KVS3500 80GB SATA 1.8" MLC Enterprise Value SSD8
00AJ045A4KWS3500 240GB SATA 1.8" MLC Enterprise Value SSD8
00AJ050A4KXS3500 400GB SATA 1.8" MLC Enterprise Value SSD8

The 2.5-inch drive bays support SAS or SATA hard disk drives (HDDs) or SATA solid-state drives (SSDs). The following table lists the supported 2.5-inch drive options. The maximum quantity supported is two.

Table 10. 2.5-inch drive options for internal disk storage
Part
number
Feature
code
Description
Supported by
ServeRAID controller
C105H1135M5115
10K SAS hard disk drives
00AD075A48SIBM 1.2TB 10K 6Gbps SAS 2.5'' G2HS HDDNoYesYes
81Y9650A282IBM 900 GB 10 K 6 Gbps SAS 2.5-inch SFF HS HDDNoYesYes
49Y20035433IBM 600 GB 10 K 6 Gbps SAS 2.5-inch SFF Slim-HS HDDNoYesYes
42D06375599IBM 300 GB 10 K 6 Gbps SAS 2.5-inch SFF Slim-HS HDDNoYesYes
15K SAS hard disk drives
81Y9670A283IBM 300 GB 15 K 6 Gbps SAS 2.5-inch SFF HS HDDNoYesYes
90Y8926A2XBIBM 146GB 15K 6Gbps SAS 2.5" SFF G2HS HDDNoYesYes
42D06775536IBM 146 GB 15 K 6 Gbps SAS 2.5-inch SFF Slim-HS HDDNoYesYes
SAS-SSD Hybrid drive
00AD102A4G7IBM 600GB 10K 6Gbps SAS 2.5'' G2HS HybridNoYesYes
10K and 15K Self-encyrpting drives (SED)
00AD085A48TIBM 1.2TB 10K 6Gbps SAS 2.5'' G2HS SEDNoYesYes
81Y9662A3EGIBM 900GB 10K 6Gbps SAS 2.5" SFF G2HS SEDNoYesYes
90Y8908A3EFIBM 600GB 10K 6Gbps SAS 2.5" SFF G2HS SEDNoYesYes
90Y8913A2XFIBM 300GB 10K 6Gbps SAS 2.5" SFF G2HS SEDNoYesYes
90Y8944A2ZKIBM 146GB 15K 6Gbps SAS 2.5" SFF G2HS SEDNoYesYes
NL SATA
81Y9730A1AVIBM 1 TB 7.2 K 6 Gbps NL SATA 2.5-inch SFF HS HDDYesYesYes
81Y9726A1NZIBM 500 GB 7.2 K 6 Gbps NL SATA 2.5-inch SFF HS HDDYesYesYes
81Y9722A1NXIBM 250 GB 7.2 K 6 Gbps NL SATA 2.5-inch SFF HS HDDYesYesYes
NL SAS
81Y9690A1P3IBM 1 TB 7.2 K 6 Gbps NL SAS 2.5-inch SFF HS HDDNoYesYes
90Y8953A2XEIBM 500GB 7.2K 6Gbps NL SAS 2.5" SFF G2HS HDDNoYesYes
42D07075409IBM 500 GB 7200 6 Gbps NL SAS 2.5-inch SFF Slim-HS HDDNoYesYes
Solid-state drives - Enterprise
41Y8331A4FLS3700 200GB SATA 2.5" MLC HS Enterprise SSDNoYesYes
41Y8336A4FNS3700 400GB SATA 2.5" MLC HS Enterprise SSDNoYesYes
41Y8341A4FQS3700 800GB SATA 2.5" MLC HS Enterprise SSDNoYesYes
00W1125A3HRIBM 100GB SATA 2.5" MLC HS Enterprise SSDNoYesYes
43W7718A2FNIBM 200 GB SATA 2.5-inch MLC HS SSDNoYesYes
49Y6129A3EWIBM 200GB SAS 2.5" MLC HS Enterprise SSDNoYesYes
49Y6134A3EYIBM 400GB SAS 2.5" MLC HS Enterprise SSDNoYesYes
49Y6139A3F0IBM 800GB SAS 2.5" MLC HS Enterprise SSDNoYesYes
49Y6195A4GHIBM 1.6TB SAS 2.5" MLC HS Enterprise SSDNoYesYes
Solid-state drives - Enterprise Value
90Y8643A2U3IBM 256 GB SATA 2.5-inch MLC HS Enterprise Value SSDNoYesYes
90Y8648A2U4IBM 128 GB SATA 2.5-inch MLC HS Enterprise Value SSDNoYesYes
49Y5844A3AUIBM 512GB SATA 2.5" MLC HS Enterprise Value SSDNoYesYes
49Y5839A3ASIBM 64GB SATA 2.5" MLC HS Enterprise Value SSDNoYesYes
00AJ000A4KMS3500 120GB SATA 2.5" MLC HS Enterprise Value SSDNoYesYes
00AJ005A4KNS3500 240GB SATA 2.5" MLC HS Enterprise Value SSDNoYesYes
00AJ010A4KPS3500 480GB SATA 2.5" MLC HS Enterprise Value SSDNoYesYes
00AJ015A4KQS3500 800GB SATA 2.5" MLC HS Enterprise Value SSDNoYesYes
00AJ355A56ZIBM 120GB SATA 2.5" MLC HS Enterprise Value SSDNoYesYes
00AJ360A570IBM 240GB SATA 2.5" MLC HS Enterprise Value SSDNoYesYes
00AJ365A571IBM 480GB SATA 2.5" MLC HS Enterprise Value SSDNoYesYes
00AJ370A572IBM 800GB SATA 2.5" MLC HS Enterprise Value SSDNoYesYes

IBM Flex System Storage Expansion Node

The x220 supports the attachment of the IBM Flex System Storage Expansion Node. The IBM Flex System Storage Expansion Node provides the ability to attach additional 12 hot-swap 2.5-inch HDDs or SSDs locally to the attached compute node. The Storage Expansion Node provides storage capacity for Network Attach Storage (NAS) workloads, providing flexible storage to match capacity, performance and reliability needs.

Model 7906-DBx includes the Storage Expansion Node as standard as listed in Table 2. All other models support the SEN as an option.

The following figure shows the IBM Flex System Storage Expansion Node attached to a compute node.


Figure 6. IBM Flex System Storage Expansion Node (right) attached to a compute node (left)

The ordering information for the Storage Expansion Node is shown in the following table.

Table 11. Ordering part number and feature code

Part numberFeature codeDescriptionMaximum
supported
68Y8588A3JFIBM Flex System Storage Expansion Node1

The Storage Expansion Node has the following features:
  • Connects directly to supported compute nodes via a PCIe 3.0 interface to the compute node's expansion connector (See Figure 3)
  • Support for 12 hot-swap 2.5-inch drive, accessible via a sliding tray
  • Support for 6 Gbps SAS and SATA drives, both HDDs and SSDs
  • Based on an LSI SAS2208 6 Gbps RAID on Chip (ROC) controller
  • Supports RAID 0, 1, 5, 10, and 50 as standard. JBOD also supported. Optional RAID 6 and 60 with a Features on Demand upgrade.
  • Optional 512 MB or 1 GB cache with cache-to-flash super capacitor offload


Note: The use of the Storage Expansion Node requires that the x220 Compute Node have both processors installed.

For more information, see the IBM Redbooks Product Guide on the IBM Flex System Storage Expansion Node, http://www.redbooks.ibm.com/abstracts/tips0914.html?Open

Internal tape drives

The server does not support an internal tape drive. However, it can be attached to external tape drives using Fibre Channel connectivity.

Optical drives

The server does not support an internal optical drive option. However, you can connect an external USB optical drive, such as the IBM and Lenovo part number 73P4515 or 73P4516, or use the remote media feature of the IMMv2 and the Chassis Management Module.

Note: The USB port on the compute node supplies up to 0.5 A at 5 V. For devices that require more power, an additional power source will be required.

Embedded 1 Gb Ethernet controller

Some models of the x220 include an Embedded 1 Gb Ethernet controller (also known as LAN on Motherboard or LOM) built into the system board. Table 2 lists what models of the x220 include the controller. Each x220 model that includes the controller also has the Compute Node Fabric Connector installed in I/O connector 1 (and physically screwed onto the system board) to provide connectivity to the Enterprise Chassis midplane. Figure 3 shows the location of the Fabric Connector.

The Fabric Connector enables port 1 on the controller to be routed to I/O module bay 1 and port 2 to be routed to I/O module bay 2. The Fabric Connector can be unscrewed and removed, if required, to allow the installation of an I/O adapter on I/O connector 1.

The Embedded 1 Gb Ethernet controller has the following features:

  • Broadcom BCM5718 based
  • Dual-port Gigabit Ethernet controller
  • PCIe 2.0 x2 host bus interface
  • Supports Wake on LAN
  • Supports Serial over LAN
  • Supports IPv6

Note: TCP/IP Offload Engine (TOE) is not supported.

I/O expansion options

The x220 has two I/O expansion connectors for attaching I/O adapter cards. There is a third expansion connector designed to connect an expansion node such as the PCIe Expansion Node. The I/O expansion connectors are a very high-density 216-pin PCIe connector. Installing I/O adapter cards allows the server to connect with switch modules in the IBM Flex System Enterprise Chassis. Each slot has one PCI Express 3.0 x8 and one PCI Express x4 interface and both slots support the same form-factor adapters.

The following figure shows the location of the I/O expansion connectors.

Location of the I/O adapter slots in the IBM Flex System x220 Compute Node
Figure 7. Location of the I/O adapter slots in the IBM Flex System x220 Compute Node

All I/O adapters are the same shape and can be used in any available slot.. A compatible switch or pass-through module must be installed in the corresponding I/O bays in the chassis, as indicated in the following table. Installing two switches means that all ports of the adapter are enabled, which improves performance and network availability.

Table 12. Adapter to I/O bay correspondence

I/O adapter slot in the serverPort on the adapterCorresponding I/O module bay in the chassis
Slot 1Port 1Module bay 1
Port 2Module bay 2
Port 3 (for 4-port cards)Module bay 1
Port 4 (for 4-port cards)Module bay 2
Slot 2Port 1Module bay 3
Port 2Module bay 4
Port 3 (for 4-port cards)Module bay 3
Port 4 (for 4-port cards)Module bay 4

The following figure shows the location of the switch bays in the IBM Flex System Enterprise Chassis.

Location of the switch bays in the IBM Flex System Enterprise Chassis
Figure 8. Location of the switch bays in the IBM Flex System Enterprise Chassis

The following figure shows how two-port adapters are connected to switches installed in the chassis.

Logical layout of the interconnects between I/O adapters and I/O modules
Figure 9. Logical layout of the interconnects between I/O adapters and I/O modules

IBM Flex System PCIe Expansion Node

The x220 supports the attachment of the IBM Flex System PCIe Expansion Node. The IBM Flex System PCIe Expansion Node provides the ability to attach additional PCI Express cards such as High IOPS SSD adatpers, fabric mezzanine cards, and next-generation graphics processing units (GPU) to supported IBM Flex System compute nodes. This capability is ideal for many applications that require high performance I/O, special telecommunications network interfaces, or hardware acceleration using a PCI Express card. The PCIe Expansion Node supports up to four PCIe 2.0 adapters and two additional Flex System expansion adapters.

The PCIe Expansion Node is attached to the x220 as shown in the following figure.

PCIe Expansion Node
Figure 10. PCIe Expansion Node

The ordering information for the PCIe Expansion Node is shown in the following table.

Table 13. Ordering part number and feature code

Part numberFeature codeDescriptionMaximum
supported
81Y8983A1BVIBM Flex System PCIe Expansion Node1

The PCIe Expansion Node has the following features:
  • Support for up to four standard PCIe 2.0 adapters:
    • Two PCIe 2.0 x16 slots that support full-length, full-height adapters
    • Two PCIe 2.0 x8 slots that support half-length, low-profile adapters
  • Support for PCIe 3.0 adapters by operating them in PCIe 2.0 mode
  • Support for one full-length, full-height double-wide adapter (consuming the space of the two full-length, full-height adapter slots)
  • Support for PCIe cards with higher power requirements -- a single adapter card (up to 225W), or to two adapters (up to 150W each)
  • Two Flex System I/O expansion connectors for to further expand the I/O capability of the attached compute node.

Note: The use of the PCIe Expansion Node requires that the x220 Compute Node have both processors installed.

For more information, see the IBM Redbooks Product Guide on the IBM Flex System PCIe Expansion Node, http://www.redbooks.ibm.com/abstracts/tips0906.html?Open

Network adapters

As described in "Embedded 1 Gb Ethernet Adapter," certain models have a Embedded 1 Gb Ethernet controller on the system board, and its ports are routed to the midplane and switches installed in the chassis through a Compute Note Fabric Connector that takes the place of an adapter in I/O slot 1.

Models without the Embedded 1 Gb Ethernet controller do not include any other Ethernet connections to the Enterprise Chassis midplane as standard. Therefore, for those models, an I/O adapter must be installed in either I/O connector 1 or I/O connector 2 to provide network connectivity between the server and the chassis midplane and ultimately to the network switches.

The following table lists the supported network adapters and upgrades. Adapters can be installed in either slot. However, compatible switches must be installed in the corresponding bays of the chassis. All adapters can also be installed in the PCIe Expansion Node.

Table 14. Network adapters

Part
number
Feature
code
DescriptionNumber
of ports
Maximum
supported*
40 Gb Ethernet
90Y3482A3HKIBM Flex System EN6132 2-port 40Gb Ethernet Adapter22
10 Gb Ethernet
90Y3554A1R1IBM Flex System CN4054 10 Gb Virtual Fabric Adapter42
90Y3558A1R0IBM Flex System CN4054 Virtual Fabric Adapter (SW Upgrade)
(Feature on Demand to provide FCoE and iSCSI support)
(one license required per adapter)
License2
90Y3466A1QYIBM Flex System EN4132 2-port 10 Gb Ethernet Adapter22
1 Gb Ethernet
49Y7900A10YIBM Flex System EN2024 4-port 1 Gb Ethernet Adapter 42
InfiniBand
90Y3454A1QZIBM Flex System IB6132 2-port FDR InfiniBand Adapter22
* For models with the Embedded 1 Gb Ethernet controller standard, the Compute Node Fabric Connector occupies the same space as an I/O adapter in I/O slot 1, so you have to remove the Fabric Connector if you plan to install an adapter in I/O slot 1.

For adapter-to-switch compatibility, see the IBM Flex System Interoperability Guide:
http://www.redbooks.ibm.com/fsig

For more information, see the list of IBM Redbooks Product Guides in the Adapter cards category:
http://www.redbooks.ibm.com/portals/puresystems?Open&page=pg&cat=adapters

Storage host bus adapters

The following table lists storage HBAs supported by the x220 server. Adapters can be installed in either slot. However, compatible switches must be installed in the corresponding bays of the chassis. All adapters can also be installed in the PCIe Expansion Node.

Table 15. Storage adapters

Part
number
Feature
code
DescriptionNumber
of ports
Maximum
supported*
Fibre Channel
88Y6370A1BPIBM Flex System FC5022 2-port 16 Gb FC Adapter22
69Y1938A1BMIBM Flex System FC3172 2-port 8 Gb FC Adapter 22
95Y2375A2N5IBM Flex System FC3052 2-port 8 Gb FC Adapter22
95Y2386A45RIBM Flex System FC5052 2-port 16Gb FC Adapter22
95Y2391A45SIBM Flex System FC5054 4-port 16Gb FC Adapter42
69Y1942A1BQIBM Flex System FC5172 2-port 16Gb FC Adapter22
* For models with the Embedded 1 Gb Ethernet controller standard, the Compute Node Fabric Connector occupies the same space as an I/O adapter in I/O slot 1, so you have to remove the Fabric Connector if you plan to install an adapter in I/O slot 1.

For more information, see the list of IBM Redbooks Product Guides in the Adapter cards category:
http://www.redbooks.ibm.com/portals/puresystems?Open&page=pg&cat=adapters

PCIe SSD adapters

The compute node supports the High IOPS SSD adapters listed in the following table.

Note: These adapters are installed in an attached PCIe Expansion Node.

Table 16. SSD adapters

Part numberFeature
code
DescriptionMaximum
supported
46C9078A3J3IBM 365GB High IOPS MLC Mono Adapter (low-profile adapter)4
46C9081A3J4IBM 785GB High IOPS MLC Mono Adapter (low-profile adapter)4
81Y4519*5985640GB High IOPS MLC Duo Adapter (full-height adapter)2
81Y4527*A1NB1.28TB High IOPS MLC Duo Adapter (full-height adapter)2
90Y4377A3DYIBM 1.2TB High IOPS MLC Mono Adapter (low-profile adapter)4
90Y4397A3DZIBM 2.4TB High IOPS MLC Duo Adapter (full-height adapter)2
* Withdrawn from marketing

For information about the IBM High IOPS adapters, the following IBM Redbooks Product Guides:

GPU and Crypto adapters

The compute node supports the GPU and Crypto adapters listed in the following table.

Note: These adapters are installed in an attached PCIe Expansion Node.

Table 17. GPU and Crypto adapters

Part numberFeature codeDescriptionMaximum
supported
94Y5960A1R4NVIDIA Tesla M2090 (full-height adapter)1*
47C2120A4F1NVIDIA GRID K1 for IBM Flex System PCIe Expansion Node1†
47C2121A4F2NVIDIA GRID K2 for IBM Flex System PCIe Expansion Node1†
47C2119A4F3NVIDIA Tesla K20 for IBM Flex System PCIe Expansion Node1†
47C2137A5HDNVIDIA Tesla K40 for IBM Flex System PCIe Expansion Node1†
47C2122A4F4Intel Xeon Phi 5110P for IBM Flex System PCIe Expansion Node1†
None4809**IBM 4765 Crypto Card (full-height adapter)2
* When this double-wide adapter is installed in the PCIe Expansion Node, it occupies both full-height slots. The low-profile slots and Flex System I/O expansion slots can still be used.
† If installed, only this adapter is supported in the system. No other PCIe adapters may be installed.
** Orderable as separate MTM 4765-001 feature 4809. Available via AAS (e-config) only.

Power supplies

Server power is derived from the power supplies installed in the chassis. There are no server options regarding power supplies.

Integrated virtualization

The x220 supports the ESXi hypervisor on a USB memory key via two internal USB ports (see Figure 3). The supported USB memory keys are listed in the following table.

There are two types of USB keys, preloaded keys or blank keys. Blank keys allow you to download an IBM customized version of ESXi and load it onto the key. The x220 supports one or two keys installed, but only certain combinations:

Supported combinations:

  • One preload key
  • One blank key
  • One preload key and one blank key
  • Two blank keys

Unsupported combinations:
  • Two preload keys

Installing two preloaded keys will prevent ESXi from booting as described in http://kb.vmware.com/kb/1035107. Having two keys installed provides a backup boot device. both devices are listed in the boot menu, which allows you to boot from either device or to set one as a backup in case the first one gets corrupted.

Table 18. Virtualization options
Part numberFeature
code
DescriptionMaximum
supported
41Y8298A2G0IBM Blank USB Memory Key for VMware ESXi Downloads2
41Y8300A2VCIBM USB Memory Key for VMware ESXi 5.01
41Y8307A383IBM USB Memory Key for VMware ESXi 5.0 Update11
41Y8311A2R3IBM USB Memory Key for VMWare ESXi 5.1 1
41Y8382A4WZIBM USB Memory Key for VMware ESXi 5.1 Update 11
41Y8385A584IBM USB Memory Key for VMware ESXi 5.51

Note: VMware is not supported with the ServeRAID C105 disk controller (Software RAID), but is supported with the use of ServeRAID H1135 controller (part number 90Y4750) or ServeRAID M5115 controller (part number 90Y4390).

Light path diagnostics

For quick problem determination when you are physically at the server, the x220 offers a three-step guided path:

  1. The Fault LED on the front panel
  2. The light path diagnostics panel, shown in the following figure.
  3. LEDs next to key components on the system board

The x220 light path diagnostics panel is visible when you remove the server from the chassis. The panel is located at the upper right side of the compute node, as shown in the following figure.

Location of x220 light path diagnostics panel
Figure 11. Location of x220 light path diagnostics panel

To illuminate the light path diagnostics LEDs, power off the compute node, slide it out of the chassis, and press the power button. The power button doubles as the light path diagnostics remind button when the server is removed from the chassis.

The meanings of the LEDs in the light path diagnostics panel are listed in the following table.

Table 19. Light path diagnostic panel LEDs
LEDMeaning
LPThe light path diagnostics panel is operational.
S BRDA system board error is detected.
MISA mismatch has occurred between the processors, DIMMs, or HDDs within the configuration (as reported by POST).
NMIA non-maskable interrupt (NMI) has occurred.
TEMPAn over-temperature condition occurs that was critical enough to shut down the server.
MEMA memory fault has occurred. The corresponding DIMM error LEDs on the system board are also lit.
ADJA fault is detected in the adjacent expansion unit (if installed).

Remote management

The server contains an IBM Integrated Management Module II (IMM2), which interfaces with the advanced management module in the chassis. The combination of these features provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, LEDs on the system board are lit to help you diagnose the problem, the error is recorded in the event log, and you are alerted to the problem. A virtual presence capability comes standard for remote server management.

Remote server management is provided through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3
  • Common Information Model (CIM)
  • Web browser

The server also supports virtual media and remote control features, which provide the following functions:
  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
  • Uploading a diskette image to the IMM2 memory and mapping it to the server as a virtual drive
  • Capturing blue-screen errors

Supported operating systems

The server supports the following operating systems:
  • Microsoft Windows Server 2008 HPC Edition
  • Microsoft Windows Server 2008 R2
  • Microsoft Windows Server 2008, Datacenter x64 Edition
  • Microsoft Windows Server 2008, Enterprise x64 Edition
  • Microsoft Windows Server 2008, Standard x64 Edition
  • Microsoft Windows Server 2008, Web x64 Edition
  • Microsoft Windows Server 2012
  • Red Hat Enterprise Linux 5 Server with Xen x64 Edition
  • Red Hat Enterprise Linux 5 Server x64 Edition
  • Red Hat Enterprise Linux 6 Server x64 Edition
  • SUSE LINUX Enterprise Server 10 for AMD64/EM64T
  • SUSE LINUX Enterprise Server 11 for AMD64/EM64T
  • SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
  • VMware ESX 4.1
  • VMware ESXi 4.1
  • VMware vSphere 5.0 (ESXi)
  • VMware vSphere 5.1 (ESXi)

Note: There is no native (in-box) driver for the ServeRAID C105 controller for Windows and Linux; the drivers must be downloaded separately. The ServeRAID C105 controller does not support for VMware, Hyper-V, Xen, or solid-state drives (SSD).

Support by some of these operating system versions will be after the date of initial availability. Check the IBM ServerProven® website for the latest information about the specific versions and service levels supported and any other prerequisites. The website can be found at the following address:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

Physical specifications

Dimensions and weight (approximate):

  • Width: 217 mm (8.6 in.)
  • Height: 56 mm (2.2 in.)
  • Depth: 492 mm (19.4 in.)
  • Maximum weight: 6.4 kg (14.11 lb)

Shipping dimensions and weight (approximate):
  • Height: 197 mm (7.8 in.)
  • Depth: 603 mm (23.7 in.)
  • Width: 430 mm (16.9 in.)
  • Weight: 8 kg (17.6 lb)

Supported environment

The IBM Flex System x220 compute node complies with ASHRAE Class A3 specifications.

This is the supported operating environment:

Power on:

  • Temperature: 5 - 40 °C (41 - 104 °F)
  • Humidity, non-condensing: -12 °C dew point (10.4 °F) and 8 - 85% relative humidity
  • Maximum dew point: 24 °C (75 °F)
  • Maximum altitude: 3048 m (10,000 ft)
  • Maximum rate of temperature change: 5 °C/hr (41 °F/hr)

Power off:
  • Temperature: 5 - 45 °C (41 - 113 °F)
  • Relative humidity: 8 - 85%
  • Maximum dew point: 27 °C (80.6 °F)

Storage (non-operating):
  • Temperature: 1 - 60 °C (33.8 - 140 °F)
  • Altitude: 3050 m (10,006 ft)
  • Relative humidity: 5 - 80%
  • Maximum dew point: 29 °C (84.2°F)

Shipment (non-operating):
  • Temperature: -40 - 60 °C (-40 - 140 °F)
  • Altitude: 10,700 m (35,105 ft)
  • Relative humidity: 5 - 100%
  • Maximum dew point: 29 °C (84.2 °F)

Warranty options

The IBM Flex System x220 Compute Node has a three-year on-site warranty with 9x5 next-business-day terms. IBM offers the warranty service upgrades through IBM ServicePac, described in this section. The IBM ServicePac is a series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

IBM ServicePac offerings are country-specific. Each country might have its own service types, service levels, response times, and terms and conditions. Not all covered types of ServicePac might be available in a particular country. For more information about IBM ServicePac offerings available in your country, see the IBM ServicePac Product Selector at:
https://www-304.ibm.com/sales/gss/download/spst/servicepac

The following table explains warranty service definitions in more detail.

Table 20. Warranty service definitions

TermDescription
IBM on-site repair (IOR)A service technician comes to the server's location for equipment repair.
24x7x2 hourA service technician is scheduled to arrive at your customer’s location within two hours after remote problem determination is completed. We provide 24-hour service, every day, including IBM holidays.
24x7x4 hourA service technician is scheduled to arrive at your customer’s location within four hours after remote problem determination is completed. We provide 24-hour service, every day, including IBM holidays.
9x5x4 hourA service technician is scheduled to arrive at your customer’s location within four business hours after remote problem determination is completed. We provide service from 8:00 a.m. - 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding IBM holidays. If it is after 1:00 p.m., and it is determined that on-site service is required, the customer can expect the service technician to arrive the morning of the following business day. For noncritical service requests, a service technician arrives by the end of the following business day.
9x5 next business dayA service technician is scheduled to arrive at your customer’s location on the business day after we receive your call, following remote problem determination. We provide service from 8:00 a.m. - 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding IBM holidays.

In general, here are the types of IBM ServicePac offerings:
  • Warranty and maintenance service upgrades:
    • One, two, three, four, or five years of 9x5 or 24x7 service coverage
    • On-site repair from the next business day to four or two hours
    • One or two years of warranty extension
  • Remote technical support services:
    • One or three years with 24x7 coverage (severity 1) or 9x5 next business day for all severities
    • Installation and startup support for IBM System x® servers
    • Remote technical support for System x servers
    • Software support - Support Line:
      • Microsoft or Linux software
      • VMware
      • IBM Systems Director

Regulatory compliance

The server conforms to the following standards:

  • ASHRAE Class A3
  • FCC - Verified to comply with Part 15 of the FCC Rules Class A
  • Canada ICES-004, issue 3 Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1
  • NOM-019
  • Argentina IEC 60950-1
  • Japan VCCI, Class A
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • China CCC (GB4943); (GB9254, Class A); (GB17625.1)
  • Taiwan BSMI CNS13438, Class A; CNS14336
  • Australia/New Zealand AS/NZS CISPR 22, Class A
  • Korea KN22, Class A, KN24
  • Russia/GOST ME01, IEC 60950-1, GOST R 51318.22, GOST R
  • 51318.249, GOST R 51317.3.2, GOST R 51317.3.3
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and
  • EN61000-3-3)
  • CISPR 22, Class A
  • TUV-GS (EN60950-1/IEC 60950-1, EK1-ITB2000)

IBM Global Financing

IBM Global Financing can help you obtain the IT solution you need while preserving funding for other strategic investments and optimizing cash flow. Our Fair Market Value (FMV) lease helps ensure that you have the latest IBM technology, and with our mid-lease upgrade capability, you can increase the capacity of the system with little to no change in monthly payments. At the end of the lease, take advantage of our flexible end-of-lease options to fit your changing business needs. IBM Global Financing has the breadth and depth of offerings, longevity, proven success, and global reach to help you develop a robust financing and asset management strategy that provides you the opportunity to use new technologies and turn your ambitious vision into a tangible solution.

Here are some other reasons why working with us makes solid financial sense:

  • Expand your purchasing power: Affordable monthly payments allow you to change the technology acquisition discussion from “what can I afford right now” to “what solution is really right for my business.” IBM Global Financing allows you to expand your purchasing power to get you the right solution.
  • Accelerate your project’s cash flow break-even point: Acquire your IBM technology today and begin to realize its benefits now. An FMV lease can help you get the solution you need now, with low monthly payments that better align upfront costs with the anticipated return on investment (ROI) from the technology.
  • Easy to acquire with affordable rates: We offer one-stop shopping for a total IT solution, so you can acquire IBM hardware, software, services, and the financing you need from one IT provider.

Plus, we provide simple, easy-to-understand contracts and quick approvals. As the world’s largest IT financing provider, with an asset base of US$35.8 billion and over 125,000 customers, IBM Global Financing offers highly competitive rates that promote low total cost of ownership (TCO) and low monthly payments.

IBM Global Financing operates in more than 50 countries. Go to http://ibm.com/financing to learn about financing options in your country and to contact a local financing specialist.

IBM Global Financing offerings are provided through IBM Credit LLC in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients. Rates and availability subject to client’s credit rating, financing terms, offering type, equipment and product type and options, and may vary by country. Non-hardware items must be one-time, nonrecurring charges and are financed by means of loans. Other restrictions may apply. Rates and offerings are subject to change, extension or withdrawal without notice and may not be available in all countries. Please contact your local IBM Global Financing representative for additional details.

Related publications and links

For more information, see the following resources:


Special Notices

This material has not been submitted to any formal IBM test and is published AS IS. It has not been the subject of rigorous review. IBM assumes no responsibility for its accuracy or completeness. The use of this information or the implementation of any of these techniques is a client responsibility and depends upon the client's ability to evaluate and integrate them into the client's operational environment. publib-b.boulder.ibm.com

Profile

Publish Date
14 May 2012

Last Update
13 June 2014


Rating: Not yet rated