IBM System x3500 M4

IBM Redbooks Product Guide


Abstract

The IBM® System x3500 M4 server provides outstanding performance for your mission-critical applications. Its energy-efficient design supports more cores, memory, and data capacity in a scalable Tower or 5U Rack package that is easy to service and manage. With more computing power per watt and the latest Intel Xeon processors, you can reduce costs while maintaining speed and availability.

Changes in the last update:
* Corrected model E5x

Contents

Table of contents


Introduction

The IBM® System x3500 M4 server provides outstanding performance for your business-critical applications. Its energy-efficient design supports more cores, memory, and data capacity in a scalable Tower or 5U Rack package that is easy to service and manage. With more computing power per watt and the latest Intel Xeon processors, you can reduce costs while maintaining speed and availability.

Suggested use: infrastructure applications, collaboration/email, web, and virtualized desktops in a workgroup or distributed environments.

Figure 1 shows the IBM System x3500 M4.

The IBM System x3500 M4
Figure 1. The IBM System x3500 M4

Did you know?

The x3500 M4 offers a flexible, scalable design and simple upgrade path to 32 HDDs, with up to eight PCIe 3.0 slots and up to 768 GB of memory. The Onboard Ethernet solution provides four standard integrated Gigabit Ethernet ports without occupying PCIe slots. Comprehensive systems management tools with the next-generation Integrated Management Module II (IMM2) make it easy to deploy, integrate, service, and manage.

Key features

A high-performance dual-socket tower server, the IBM System x3500 M4, can deliver the scalability, reliable performance, and optimized efficiency for your business-critical applications. Start with the basics and upgrade as your business changes without jeopardizing existing investments. Virtualizing the PC infrastructure into one server can provide access to a powerful server with abundant storage space, while significantly reducing IT costs.


Scalability and performance

The x3500 M4 offers numerous features to boost performance, improve scalability, and reduce costs:

  • The Intel Xeon processor E5-2600 product family improves productivity by offering superior system performance with 8-core processors and up to 2.9 GHz core speeds, up to 20 MB of L3 cache, and two QPI interconnect links of up to 8 GT/s.
  • Up to two processors, 16 cores, and 32 threads maximize the concurrent execution of multi-threaded applications.
  • Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows CPU cores to run at maximum speeds during peak workloads by temporary going beyond processor TDP.
  • Intel Hyper-Threading Technology boosts performance for multi-threaded applications by enabling simultaneous multi-threading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads.
  • Intel Advanced Vector Extensions (AVT) can significantly improve floating point performance for compute-intensive technical and scientific applications.
  • Twenty-four Load Reduced DIMMs (LRDIMMs) of 1333 MHz DDR3 ECC memory provide speed, high availability, and a memory capacity of up to 768 GB.
  • The theoretical maximum memory bandwidth of the Intel Xeon processor E5 family is 51.6 GBps, which is 60% more than in the previous generation of Intel Xeon processors.
  • Up to 32 drive bays together with internal backup and optical drive at the same time provide a flexible and scalable all-in-one platform to meet increasing demands.
  • The server has four integrated Gigabit Ethernet ports that double the network throughput compared with the previous generation of IBM System x® servers.
  • The server offers PCI Express 3.0 I/O expansion capabilities that improve the theoretical maximum bandwidth by almost 100% (8 GT/s per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GTps per link using 8b/10b encoding).
  • With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E5 family. This helps to dramatically reduce I/O latency and increase overall system performance.


Availability and serviceability

The x3500 M4 provides many features to simplify serviceability and increase system uptime:
  • The server offers Chipkill, memory mirroring and memory rank sparing for redundancy in the event of a non-correctable memory failure.
  • Tool-less cover removal provides easy access to upgrades and serviceable parts, such as CPU, memory, and adapter cards.
  • The server offers hot-swap drives supporting RAID redundancy for data protection and greater system uptime.
  • The server has up to two redundant hot-swap power supplies and up to six simple swap N+N redundant fans to provide availability for business-critical applications.
  • The power source independent light path diagnostics panel and individual light path LEDs quickly lead the technician to failed (or failing) components. This simplifies servicing, speeds up problem resolution and helps improve system availability.
  • The Predictive Failure Analysis (PFA) detects when system components (for example, processors, memory, hard disk drives) operate outside of standard thresholds and generates pro-active alerts in advance of possible failure, therefore increasing uptime.
  • Solid-state drives (SSDs) offer significantly better reliability than traditional mechanical HDDs for greater uptime.
  • Built-in Integrated Management Module Version II (IMM2) continuously monitors system parameters, triggers alerts, and performs recovering actions in case of failures to minimize downtime.
  • Built-in diagnostics using Dynamic Systems Analysis (DSA) Preboot speeds up troubleshooting tasks to reduce service time.
  • Three-year customer replaceable unit and onsite limited warranty, next business day 9x5. Optional service upgrades available.


Manageability and security

Powerful systems management features simplify local and remote management of the x3500 M4:
  • The server includes an Integrated Management Module II (IMM2) to monitor server availability and perform remote management.
  • Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
  • Integrated Trusted Platform Module (TPM) 1.2 support enables advanced cryptographic functionality, such as digital signatures and remote attestation.
  • Industry-standard AES NI support for faster, stronger encryption.
  • IBM Systems Director is included for proactive systems management. It offers comprehensive systems management tools that help to increase up-time, reduce costs, and improve productivity through advanced server management capabilities.
  • Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space protected from all other software running on a system.


Energy efficiency

The x3500 M4 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:
  • Energy-efficient planar components help lower operational costs.
  • High-efficient 550 W, 750 W and 900 W power supplies with 80 PLUS Platinum certification.
  • The Intel Xeon processor E5-2600 product family offers significantly better performance over the previous generation while fitting into the same thermal design power (TDP) limits.
  • Intel Intelligent Power Capability powers individual processor elements on and off as needed, to reduce power draw.
  • Low-voltage Intel Xeon processors draw less energy to satisfy demands of power and thermally constrained data centers and telecommunication environments.
  • Low-voltage 1.35 V DDR3 memory RDIMMs consume 15% less energy than 1.5 V DDR3 RDIMMs.
  • Solid state drives (SSDs) consume as much as 80% less power than traditional spinning 2.5-inch HDDs.
  • The server uses hexagonal ventilation holes, a part of IBM Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, providing more efficient airflow through the system.
  • IBM Systems Director Active Energy Manager™ provides advanced data center power notification and management to help achieve lower heat output and reduced cooling needs.

Locations of key components and connectors

Figure 2 shows the front of the server.

Front view of the IBM System x3500 M4
Figure 2. Front view of the IBM System x3500 M4

Figure 3 shows the rear of the server.

Rear view of the IBM System x3500 M4
Figure 3. Rear view of the IBM System x3500 M4

Figure 4 shows the locations of key components inside the server.

Inside view of the IBM System x3500 M4
Figure 4. Inside view of the IBM System x3500 M4

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications

ComponentsSpecification
Form factorTower or 5U Rack.
ProcessorUp to two Intel Xeon processor E5-2600 product family CPUs with eight cores (up to 2.9 GHz) or six cores (up to 2.9 GHz) or quad-cores (up to 3.3 GHz). Two QPI links up to 8.0 GT/s each. Up to 1600 MHz memory speed. Up to 20 MB L3 cache.
ChipsetIntel C602J.
MemoryUp to 24 DDR3 DIMM sockets (12 DIMMs per processor). RDIMMs, UDIMMs, and LRDIMMs are supported, but memory types cannot be intermixed.
Memory maximumsWith LRDIMMs: Up to 768 GB with 24x 32 GB LRDIMMs and two processors.
With RDIMMs: Up to 384 GB with 24x 16 GB RDIMMs and two processors.
With UDIMMs: Up to 64 GB with 16x 4 GB UDIMMs and two processors.
Memory protectionECC, Chipkill (for x4-based memory DIMMs), memory mirroring, and memory rank sparing.
Disk drive baysUp to thirty-two 2.5" hot-swap SAS/SATA HDDs, or up to eight 3.5" hot-swap SAS/SATA HDDs, or up to eight 3.5" Simple Swap SATA HDDs.
Maximum internal storage 28.8 TB with 900 GB 2.5" SAS HDDs, or 32 TB with 1 TB 2.5" SATA HDDs, or 24 TB with 3 TB 3.5" SATA HDDs. Intermix of SAS/SATA is supported.
RAID supportRAID 0, 1, 10 with M1115 or ServeRAID M5110. Optional upgrade to RAID 5, 50 available for M1115. Optional upgrades to RAID 5, 50 are available for M5110 (zero-cache, 512 MB battery-backed cache, 512 MB or 1 GB flash-backed cache). Optional upgrade to RAID 6, 60 available for M5110.
Optical drive baysTwo half-height 5.25" bays for optical or tape drives. Supports DVD-ROM or Multiburner.
Tape drive baysTwo half-height 5.25" bays for optical or tape drives. Support for one RDX or DDS internal USB tape drive. Supports up to two LTO internal SAS tape drives.
Network interfacesFour integrated Gigabit Ethernet 1000BASE-T ports (RJ-45) based on Intel I350AM4 Quad Port GbE LAN Controller chip.
PCI Expansion slots Up to eight slots with two processors and six slots when one CPU is installed. All slots are PCIe 3.0 slots except Slot 1, which is a Gen 2 slot:
  • Slot 1: PCIe x8 (x4 wired); full-height, half-length (supports optional PCI-X 64 bit/133 MHz interposer card)
  • Slot 2: PCIe x8; full-height, half-length
  • Slot 3: PCIe x8; full-height, full-length
  • Slot 4: PCIe x8 (x4 wired); full-height, full-length
  • Slot 5: PCIe x16; full-height, full-length
  • Slot 6: PCIe x8 (x4 wired); full-height, full-length
  • Slot 7: PCIe x16; full-height, full-length (requires second processor)
  • Slot 8: PCIe x16; full-height, full-length (requires second processor)
PortsTwo USB 2.0 ports on front. Four USB 2.0, one DB-15 video, one DB-9 serial, one RJ-45 systems management, four RJ-45 GbE network ports on rear. Two internal USB ports (for embedded hypervisor and internal tape drive).
CoolingIBM Calibrated Vectored Cooling with up to six simple swap fans (two fans shipped standard on single processor models and three fans shipped on dual processor models) with optional N+N redundancy available .
Power supplyUp to two redundant hot-swap 550 W ac, 750 W ac or 900 W ac power supplies (80 PLUS Platinum certification).
Hot-swap partsHard drives, power supplies.
Systems management UEFI, IBM Integrated Management Module II (IMM2), Predictive Failure Analysis, Light Path Diagnostics, Automatic Server Restart, IBM Systems Director and IBM Systems Director Active Energy Manager, IBM ServerGuide. Optional IMM Advanced Upgrade via Feature on Demand (FoD) for remote presence (graphics, keyboard and mouse, virtual media).
Security featuresPower-on password, administrator's password, Trusted Platform Module (TPM).
VideoMatrox G200eR2 with 16 MB memory integrated into the IMM2. Maximum resolution is 1600x1200 at 75 Hz with 16 M colors.
Operating systems supported Microsoft Windows Server 2008 R2 and 2008, Red Hat Enterprise Linux 5 and 6, SUSE Linux Enterprise Server 10 and 11, VMware ESX 4.1 and ESXi 4.1, and VMware vSphere 5.
Limited warranty 3-year customer-replaceable unit and onsite limited warranty with 9x5/NBD.
Service and supportOptional service upgrades are available through IBM ServicePacs®: 4-hour or 2-hour response time, 8-hour fix time, 1-year or 2-year warranty extension, remote technical support for IBM hardware and selected IBM and third-party (Microsoft, Linux, VMware) software.
DimensionsWidth: 218 mm (8.6 in), depth: 750 mm (29.5 in), height: 440 mm (17.3 in).
WeightMinimum configuration: 25.0 kg (55.1 lb), maximum: 39.8 kg (87.7lb).

The x3500 M4 servers are shipped with the following items:
  • Statement of Limited Warranty
  • Important Notices
  • Registration flyer
  • Documentation CD that contains the Installation and User's Guide
  • IBM Systems Director 6.3 Base for x86 DVD-ROM
  • One 2.8 m C13 line cord (country-specific)

Note: EMEA models do not contain line cord. It must be purchased separately.

Standard models

The following table lists the standard models.

Table 2. Standard models

Model Processor (model, cores core speed, cores,
L3 cache, memory speed, TDP) (2 maximum)
MemoryRAID controllerDisk bays (std / max)DisksNetworkOpticalPower supply
Models announced March 2012
7383-A2x1x Xeon E5-2603 4C 1.8GHz 10MB 1066MHz 80W1x 4 GBM11158x 2.5" HS / 32Optional4x GbEDVD-ROM1x 750 W
7383-B2x1x Xeon E5-2609 4C 2.4GHz 10MB 1066MHz 80W1x 4 GBM11158x 2.5" HS / 32Optional4x GbEDVD-ROM1x 750 W
7383-C2x1x Xeon E5-2620 6C 2.0GHz 15MB 1333MHz 95W1x 8 GBM11158x 2.5" HS / 32Optional4x GbEDVD-ROM1x 750 W
7383-C4x1x Xeon E5-2620 6C 2.0GHz 15MB 1333MHz 95W1x 8 GBM11158x 3.5" HS / 8Optional4x GbEDVD-ROM1x 750 W
7383-D2x1x Xeon E5-2630 6C 2.3GHz 15MB 1333MHz 95W1x 8 GBM11158x 2.5" HS / 32Optional4x GbEDVD-ROM1x 750 W
7383-F2x1x Xeon E5-2640 6C 2.5GHz 15MB 1333MHz 95W1x 8 GBM5110 512MB Flash8x 2.5" HS / 32Optional4x GbEDVD-ROM1x 750 W
7383-G2x1x Xeon E5-2650 8C 2.0GHz 20MB 1600MHz 95W1x 8 GBM5110 1GB Flash8x 2.5" HS / 32Optional4x GbEDVD-ROM1x 900 W
7383-H2x1x Xeon E5-2670 8C 2.6GHz 20MB 1600MHz 115W1x 8 GBM5110 1GB Flash8x 2.5" HS / 32Optional4x GbEDVD-ROM1x 900 W
7383-J2x1x Xeon E5-2680 8C 2.7GHz 20MB 1600MHz 130W1x 8 GBM5110 1GB Flash8x 2.5" HS / 32Optional4x GbEDVD-ROM1x 900 W


Refer to the Specifications section for information about standard features of the server.

Express models

The following table lists the express models.

Table 3. Express models

ModelProcessor†RAMRAIDDisk baysDisksNetworkOpticalPower
North America (NA)
7383-EAU1x Xeon E5-2609 4C 2.4GHz
10MB 1066MHz 80W
1x 4 GBM11158x 3.5" HS / 8Optional4x GbEMulti-
burner
1x 750 W
7383-EBU1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB(f)
8x 3.5" HS / 8Optional4x GbEMulti-
burner
1x 750 W
7383-ECU1x Xeon E5-2640 6C 2.5GHz
15MB 1333MHz 95W
2x 8 GBM5110
512MB(f)
8x 2.5" HS / 32Optional4x GbEMulti-
burner
2x 750 W
7383-EDU1x Xeon E5-2650 8C 2.0GHz
20MB 1600MHz 95W
1x 8 GBM5110
1GB(f)
8x 2.5" HS / 32Optional4x GbEMulti-
burner
1x 750 W
Latin America (LA)
7383-EAU1x Xeon E5-2609 4C 2.4GHz
10MB 1066MHz 80W
1x 4 GBM11158x 3.5" HS / 8Optional4x GbEMulti-
burner
1x 750 W
7383-EBU1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB(f)
8x 3.5" HS / 8Optional4x GbEMulti-
burner
1x 750 W
7383-ECU1x Xeon E5-2640 6C 2.5GHz
15MB 1333MHz 95W
2x 8 GBM5110
512MB(f)
8x 2.5" HS / 32Optional4x GbEMulti-
burner
2x 750 W
7383-EDU1x Xeon E5-2650 8C 2.0GHz
20MB 1600MHz 95W
1x 8 GBM5110
1GB(f)
8x 2.5" HS / 32Optional4x GbEMulti-
burner
1x 750 W
Europe Integrated Operating Team (IOT)
7383-E1G1x Xeon E5-2603 4C 1.8GHz
10MB 1066MHz 80W
1x 4 GBM11158x 3.5" HS / 8Optional4x GbEMulti-
burner
1x 750 W
7383-E2G1x Xeon E5-2603 4C 1.8GHz
10MB 1066MHz 80W
1x 4 GBM11158x 2.5" HS / 32Optional4x GbEMulti-
burner
1x 750 W
7383-E3G1x Xeon E5-2609 4C 2.4GHz
10MB 1066MHz 80W
1x 4 GBM5110
512MB
8x 2.5" HS / 322x 300GB
10k 2.5" SAS
4x GbEMulti-
burner
1x 750 W
7383-E4G1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB
8x 2.5" HS / 32Optional4x GbEMulti-
burner
2x 750 W
7383-E5G1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB(f)
8x 3.5" HS / 8Optional4x GbEMulti-
burner
1x 750 W
7383-E6G1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB(f)
8x 2.5" HS / 322x 300GB
10k 2.5" SAS
4x GbEMulti-
burner
1x 750 W
Central and Eastern Europe (CEE) and Middle East & Africa (MEA)
7383-E1G1x Xeon E5-2603 4C 1.8GHz
10MB 1066MHz 80W
1x 4 GBM11158x 3.5" HS / 8Optional4x GbEMulti-
burner
1x 750 W
7383-E2G1x Xeon E5-2603 4C 1.8GHz
10MB 1066MHz 80W
1x 4 GBM11158x 2.5" HS / 32Optional4x GbEMulti-
burner
1x 750 W
7383-E3G1x Xeon E5-2609 4C 2.4GHz
10MB 1066MHz 80W
1x 4 GBM5110
512MB
8x 2.5" HS / 322x 300GB
10k 2.5" SAS
4x GbEMulti-
burner
1x 750 W
7383-E5G1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB(f)
8x 3.5" HS / 8Optional4x GbEMulti-
burner
1x 750 W
7383-E6G1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB(f)
8x 2.5" HS / 322x 300GB
10k 2.5" SAS
4x GbEMulti-
burner
1x 750 W
7383-K1G1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB(f)
8x 2.5" HS / 323x 300GB
10k 2.5" SAS
4x GbEMulti-
burner
2x 750 W
7383-K3G1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB(b)
8x 2.5" HS / 32Optional4x GbEMulti-
burner
2x 750 W
Russia/Commonwealth of Independent States (CIS)
7383-E1G1x Xeon E5-2603 4C 1.8GHz
10MB 1066MHz 80W
1x 4 GBM11158x 3.5" HS / 8Optional4x GbEMulti-
burner
1x 750 W
7383-K2G1x Xeon E5-2609 4C 2.4GHz
10MB 1066MHz 80W
1x 4 GBM5110
512MB(b)
8x 2.5" HS / 32Optional4x GbEMulti-
burner
1x 750 W
7383-K3G1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB(b)
8x 2.5" HS / 32Optional4x GbEMulti-
burner
2x 750 W
7383-K4G1x Xeon E5-2620 6C 2.0GHz
15MB 1333MHz 95W
1x 8 GBM5110
512MB(f)
8x 3.5" HS / 8Optional4x GbEMulti-
burner
2x 750 W
† Processor detail: Processor quantity and model, number of cores, core speed, L3 cache, memory speed, power consumption.
(f) The ServeRAID M5110 RAID controller in this model includes flash-backed cache. The cache size is 512 MB or 1 GB, as indicated.
(b) The ServeRAID M5110 RAID controller in this model includes battery-backed cache. The cache size is 512 MB or 1 GB, as indicated.

Processor options

The x3500 M4 supports the processor options listed in the following table. The server supports up to two processors. This table shows which server models have each processor standard. If there is no corresponding where-used model for a particular processor, then this processor is only available through CTO.

Table 4. Processor options

Part numberFeature codeDescriptionStandard models
where used
Intel Xeon processor E5-2600 product family
90Y5942A1GPIntel Xeon Processor E5-2603 4C 1.8GHz 10MB Cache 1066MHz 80WA2x
90Y5944A1GRIntel Xeon Processor E5-2609 4C 2.4GHz 10MB Cache 1066MHz 80WB2x
90Y5945A1GSIntel Xeon Processor E5-2620 6C 2.0GHz 15MB Cache 1333MHz 95WC2x, C4x
90Y5946A1GTIntel Xeon Processor E5-2630 6C 2.3GHz 15MB Cache 1333MHz 95WD2x
90Y5953A1H0Intel Xeon Processor E5-2630L 6C 2.0GHz 15MB Cache 1333MHz 60W-
94Y7342A2CTIntel Xeon Processor E5-2637 2C 3.0GHz 5MB Cache 1600MHz 80W-
90Y5947A1GUIntel Xeon Processor E5-2640 6C 2.5GHz 15MB Cache 1333MHz 95WF2x
94Y7341A2CSIntel Xeon Processor E5-2643 4C 3.3GHz 10MB Cache 1600MHz 130W-
00D4474A393Intel Xeon Processor E5-2648L 8C 1.8GHz 20MB Cache 1600MHz 70W-
90Y5948A1GVIntel Xeon Processor E5-2650 8C 2.0GHz 20MB Cache 1600MHz 95WG2x
90Y5954A1H1Intel Xeon Processor E5-2650L 8C 1.8GHz 20MB Cache 1600MHz 70W-
00D4473A392Intel Xeon Processor E5-2658 8C 2.1GHz 20MB Cache 1600MHz 95W-
90Y5949A1GWIntel Xeon Processor E5-2660 8C 2.2GHz 20MB Cache 1600MHz 95W-
94Y7442A2H6Intel Xeon Processor E5-2665 8C 2.4GHz 20MB Cache 1600MHz 115W-
90Y5951A1GYIntel Xeon Processor E5-2667 6C 2.9GHz 15MB Cache 1600MHz 130W-
90Y5955A1H2Intel Xeon Processor E5-2670 8C 2.6GHz 20MB Cache 1600MHz 115WH2x
90Y5950A1GXIntel Xeon Processor E5-2680 8C 2.7GHz 20MB Cache 1600MHz 130WJ2x
94Y7343A2CUIntel Xeon Processor E5-2690 8C 2.9GHz 20MB Cache 1600MHz 135W-

Memory options

The IBM System x3500 M4 supports DDR3 memory. The server supports up to 12 DIMMs when one processor is installed and up to 24 DIMMs when two processors are installed. Each processor has four memory channels, and there are three DIMMs per channel. The following rules apply when selecting the memory configuration:

  • The server supports UDIMMs, RDIMMs, and LRDIMMs.
  • Mixing different types of memory (UDIMMs, RDIMMs, and LRDIMMs) is not supported.
  • Mixing 1.5 V and 1.35 V DIMMs in the same server is supported. In such a case all DIMMs operate at 1.5 V.
  • The maximum number of ranks per channel is eight (with the exception of Load Reduced DIMMs, where more than eight ranks are supported because one quad-rank LRDIMM provides the same electrical load on a memory bus as a single-rank RDIMM).
  • The maximum quantity of DIMMs that can be installed in a server depends on the number of CPUs, DIMM type, rank, and operating voltage, as shown in the "Max. qty supported" row in Table 5.
  • All DIMMs in the server operate at the same speed, which is determined as the lowest value of:
    • Memory speed supported by specific CPU
    • Lowest maximum operating speed for the selected memory configuration that depends on rated speed, operating voltage, and quantity of DIMMs per channel, as shown in the "Max. operating speed" section in Table 5

Table 5. Maximum memory speeds
DIMM type

DIMM specification
UDIMMRDIMMLRDIMM
RankDual rankSingle rankDual rankQuad rankQuad rank
Rated speed1333 MHz1333 MHz1600 MHz1333 MHz1600 MHz1066 MHz1333 MHz
Rated voltage1.35 V1.35 V1.5 V1.35 V1.5 V1.35 V1.35 V
Operating voltage1.35 V1.5 V1.35 V1.5 V1.5 V1.35 V1.5 V1.5 V1.35 V1.5 V1.35 V1.5 V
Max. qty supported*161616242416242416162424
Max. DIMM capacity4 GB4 GB4 GB4 GB4 GB16 GB16 GB16 GB16 GB16 GB32 GB32 GB
Max. memory capacity64 GB64 GB64 GB96 GB96 GB256 GB384 GB384 GB256 GB256 GB768 GB768 GB
Max. memory
at rated speed
64 GB64 GB64 GB64 GB64 GB256 GB256 GB256 GBNS**128 GB256 GB512 GB
Max. operating speed_
1 DIMM per channel1333
MHz
1333
MHz
1333
MHz
1333
MHz
1600
MHz
1333
MHz
1333
MHz
1600
MHz
800
MHz
1066
MHz
1333
MHz
1333
MHz
2 DIMMs per channel1333
MHz
1333
MHz
1333
MHz
1333
MHz
1600
MHz
1333
MHz
1333
MHz
1600
MHz
800
MHz
800
MHz
1066
MHz
1333
MHz
3 DIMMs per channelNS**NS**NS**1066
MHz
1066
MHz
NS**1066
MHz
1066
MHz
NS**NS**1066
MHz
1066
MHz
* The maximum quantity supported is shown for two processors installed. When one processor installed the maximum quantity supported is a half of that shown.
** NS = Not supported.

The following memory protection technologies are supported:
  • ECC
  • Chipkill (for x4-based memory DIMMs)
  • Memory mirroring
  • Memory sparing

Chipkill works only in independent channel mode (default operational mode) and supports only x4-based memory DIMMs.

If memory mirroring is used, then DIMMs must be installed in pairs (minimum of one pair per CPU), and both DIMMs in a pair must be identical in type and size.

If memory rank sparing is used, then a minimum of one quad-rank DIMM or two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need being identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs installed.

Note: Chipkill, memory mirroring, and memory rank sparing modes are mutually exclusive. Only one operational memory mode can be enabled on a server, and it is a system-wide setting.

The following table lists memory options available for the x3500 M4 server.

Table 6. Memory options
Part numberFeature codeDescriptionMaximum quantity
supported
Standard models
where used
UDIMMs
49Y1403A0QS2GB (1x2GB, 1Rx8, 1.35V) PC3L-10600 CL9 ECC DDR3 1333MHz LP UDIMM16 (8 per CPU)-
49Y140486484GB (1x4GB, 2Rx8, 1.35V) PC3L-10600 CL9 ECC DDR3 1333MHz LP UDIMM16 (8 per CPU)-
RDIMMs
49Y140589402GB (1x2GB, 1Rx8, 1.35V) PC3L-10600 CL9 ECC DDR3 1333 MHz LP RDIMM24 (12 per CPU)-
49Y140689414GB (1x4GB, 1Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 1333 MHz LP RDIMM24 (12 per CPU)-
49Y1559A28Z4GB (1x4GB, 1Rx4, 1.5V) PC3-12800 CL11 ECC DDR3 1600MHz LP RDIMM24 (12 per CPU)-
49Y140789424GB (1x4GB, 2Rx8, 1.35V) PC3L-10600 CL9 ECC DDR3 1333 MHz LP RDIMM24 (12 per CPU)A2x, B2x
90Y3178A24L4GB (1x4GB, 2Rx8, 1.5V) PC3-12800 CL11 ECC DDR3 1600MHz LP RDIMM24 (12 per CPU)-
49Y139789238GB (1x8GB, 2Rx4, 1.35V) PC3L-10600 CL9 ECC 1333 MHz LP RDIMM24 (12 per CPU)C2x, C4x, D2x, F2x, G2x, H2x, J2x
90Y3109A2928GB (1x8GB, 2Rx4, 1.5V) PC3-12800 CL11 ECC DDR3 1600MHz LP RDIMM24 (12 per CPU)-
49Y1563A1QT16GB (1x16GB, 2Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 1333MHz LP RDIMM24 (12 per CPU)-
00D4968A2U516GB (1x16GB, 2Rx4, 1.5V) PC3-12800 CL11 ECC DDR3 1600MHz LP RDIMM24 (12 per CPU)-
49Y1400893916GB (1x16GB, 4Rx4, 1.35V) PC3L-8500 CL7 ECC DDR3 1066MHz LP RDIMM16 (8 per CPU)-
LRDIMMs
90Y3105A29132GB (1x32GB, 4Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 1333MHz LP LRDIMM24 (12 per CPU)-

Internal disk storage options

The IBM System x3500 M4 server supports the following internal storage configurations:

  • 8x 3.5" Simple Swap SATA hard drive bays (only available in CTO)
  • 8x 3.5" hot-swap SAS/SATA hard drive bays
  • 8x 3.5" hot-swap SAS/SATA drive bays + 8x 2.5" Slim-SFF SAS/SATA hot-swap drive bays (only available in CTO, requires two RAID controllers)
  • 8x 2.5" Slim-SFF SAS/SATA hot-swap hard drive bays
  • 16x 2.5" Slim-SFF SAS/SATA hot-swap hard drive bays
  • 24x 2.5" Slim-SFF SAS/SATA hot-swap hard drive bays
  • 32x 2.5" Slim-SFF SAS/SATA hot-swap hard drive bays

Figure 5 shows these configurations.

Internal drive configurations
Figure 5. Internal drive configurations


Backplanes

Standard models of x3500 M4 ship with eight (all models except C4x) 2.5" Slim-SFF SAS/SATA hot-swap drive bays. Model C4x ships with eight 3.5" SAS/SATA hot-swap hard drive bays. The following table shows internal storage expansion options available for the x3500 M4 server.

Table 7. Internal storage expansion options
Part numberFeature
code
NameMaximum quantity
supported
94Y5978A1WZAdditional 8 x 2.5” Hot-Swap SAS/SATA Upgrade Kit for 16 or 24 HDDs
(shown in Figure 5 as an Upgrade 1 used in configurations 4, 5, and 6)
2
81Y7010A1FWAdditional 8 x 2.5" Hot-Swap SAS/SATA Upgrade Kit for 32 HDDs
(shown in Figure 5 as an Upgrade 2 used in configuration 6)
1

These options have the following descriptions:
  • 94Y5978 upgrades models with eight hot-swap 2.5" drive bays to 16 hot-swap 2.5" drive bays or models with 16 hot-swap 2.5" drive bays to 24 hot-swap 2.5" drive bays. This option includes a SAS expander card that is mounted on an HDD backplane, and does not consume a PCIe slot.
  • 81Y7010 upgrades models with 24 hot-swap 2.5" drive bays to 32 hot-swap 2.5" drive bays. This option does not include an SAS expander.

As shown in Figure 5, each configuration supports an optical drive and a tape drive. All standard configurations ship with DVD-ROM optical drive. For configure-to-order (CTO) configurations, you can add a tape drive instead of an optical drive if so desired.

Configurations 4, 5, and 6 shown in Figure 5 can be implemented with one or two RAID controllers (M1115 or M5110). Configuration 2 requires two RAID controllers.


RAID controllers

The following table lists the RAID controllers and additional options used for internal disk storage of the x3500 M4 server.

Table 8. Controllers for internal storage
Part numberFeature codeDescriptionMax quantity
supported
Standard models
where used
81Y4448A1MZServeRAID M1115 SAS/SATA Controller2A2x, B2x, C2x, C4x, D2x
81Y4542A1X1ServeRAID M1100 Series Zero Cache/RAID 5 Upgrade1*-
81Y4481A347ServeRAID M5110 SAS/SATA Controller2F2x, G2x, H2x, J2x
81Y4544A1X2ServeRAID M5100 Series Zero Cache/RAID 5 Upgrade1*-
81Y4484A1J3ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade2-
81Y4487A1J4ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade2F2x
81Y4559A1WYServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade2G2x, H2x, J2x
81Y4508A22EServeRAID M5100 Series Battery Kit2**-
81Y4546A1X3ServeRAID M5100 Series RAID 6 Upgrade1*†-
90Y4273A2MCServeRAID M5100 Series SSD Performance Accelerator1*-
90Y4318A2MDServeRAID M5100 Series SSD Caching Enabler1*-
46M09123876IBM 6Gb Performance Optimized HBA1*-
* One M1100 or M5100 Series FoD software license is required per server.
** The ServeRAID M5100 Series Battery Kit (81Y4508) is only supported with ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade (81Y4484).
† The ServeRAID M5100 Series RAID 6 Upgrade (81Y4546) requires RAID 5 Upgrade.

The ServeRAID M1115 SAS/SATA Controller has the following specifications:
  • Eight internal 6 Gbps SAS/SATA ports
  • Two x4 mini-SAS internal connectors (SFF-8087)
  • Supports RAID levels 0, 1, and 10
  • Supports RAID levels 5 and 50 with optional M1100 Series RAID 5 upgrades
  • 6 Gbps throughput per port
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS2008 6 Gbps ROC controller

The ServeRAID M5110 SAS/SATA Controller has the following specifications:
  • Eight internal 6 Gbps SAS/SATA ports
  • Two x4 mini-SAS internal connectors (SFF-8087)
  • Supports RAID levels 0, 1, and 10
  • Supports RAID levels 5 and 50 with optional M5100 Series RAID 5 upgrades
  • Supports RAID 6 and 60 with the optional M5100 Series RAID 6 Upgrade
  • Supports 512 MB battery-backed cache or 512 MB or 1 GB flash-backed cache
  • 6 Gbps throughput per port
  • PCIe 3.0 x8 3 host interface
  • Based on the LSI SAS2208 6 Gbps ROC controller

The IBM 6Gb Performance Optimized HBA has the following specifications:
  • Eight internal 6 Gbps SAS/SATA ports
  • Two x4 mini-SAS internal connectors (SFF-8087)
  • Supports up to 290,000 I/Os per second
  • Supports solid-state drives only (no support for hard drives)
  • RAID levels: None
  • 6 Gbps throughput per port
  • PCIe 2.0 x8 host interface
  • Based on the LSI SAS2008 6 Gbps controller

For more information, see the list of IBM Redbooks Product Guides in the RAID adapters category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=raid

Internal disk drive options

The following table lists hard drive options for internal disk storage of the x3500 M4 server.

Table 9. Disk drive options for internal disk storage
Part numberFeature
code
DescriptionMaximum
supported
2.5" NL SATA Hot-Swap HDDs
81Y9722A1NXIBM 250GB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD32
81Y9726A1NZIBM 500GB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD32
81Y9730A1AVIBM 1TB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD32
2.5" NL SAS Hot-Swap HDDs
90Y8953A2XEIBM 500GB 7.2K 6Gbps NL SAS 2.5" SFF G2HS HDD32
81Y9690A1P3IBM 1TB 7.2K 6Gbps NL SAS 2.5" SFF HS HDD32
2.5" SAS Hot-Swap HDDs
90Y8926A2XBIBM 146GB 15K 6Gbps SAS 2.5" SFF G2HS HDD32
90Y8944A2ZKIBM 146GB 15K 6Gbps SAS 2.5" SFF G2HS SED32
90Y8877A2XCIBM 300GB 10K 6Gbps SAS 2.5" SFF G2HS HDD32
90Y8913A2XFIBM 300GB 10K 6Gbps SAS 2.5" SFF G2HS SED32
81Y9670A283IBM 300GB 15K 6Gbps SAS 2.5" SFF HS HDD32
90Y8872A2XDIBM 600GB 10K 6Gbps SAS 2.5" SFF G2HS HDD32
81Y9650A282IBM 900GB 10K 6Gbps SAS 2.5" SFF HS HDD32
2.5" solid-state drives (SSDs)
43W7718A2FNIBM 200GB SATA 2.5" MLC HS SSD32
49Y5839A3ASIBM 64GB SATA 2.5" MLC HS Enterprise Value SSD32
90Y8648A2U4IBM 128GB SATA 2.5" MLC HS Enterprise Value SSD32
90Y8643A2U3IBM 256GB SATA 2.5" MLC HS Enterprise Value SSD32
49Y5844A3AUIBM 512GB SATA 2.5" MLC HS Enterprise Value SSD32
3.5" SAS hot-swap HDDs
49Y6092A3DVIBM 300GB 15K 6 Gbps SAS 3.5" G2HS HDD8
49Y6097A3DWIBM 450GB 15K 6 Gbps SAS 3.5" G2HS HDD8
49Y6102A3DXIBM 600GB 15K 6 Gbps SAS 3.5" G2HS HDD8
3.5" NL SAS Hot-swap HDDs
90Y8567A26MIBM 1TB 7.2K 6Gbps NL SAS 3.5" G2HS HDD8
90Y8572A2U0IBM 2TB 7.2K 6Gbps NL SAS 3.5" G2HS HDD8
90Y8577A2R2IBM 3TB 7.2K 6Gbps NL SAS 3.5" G2HS HDD8
3.5" NL SATA Hot-swap HDDs
81Y9786A22YIBM 500GB 7.2K 6Gbps NL SATA 3.5" G2HS HDD8
81Y9790A22PIBM 1TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD8
81Y9794A22TIBM 2TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD8
81Y9798A22SIBM 3TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD8
3.5" NL SATA Simple-Swap HDDs
81Y9802A22UIBM 500GB 7.2K 6Gbps NL SATA 3.5" G2SS HDD8
81Y9806A22XIBM 1TB 7.2K 6Gbps NL SATA 3.5" G2SS HDD8
81Y9810A22WIBM 2TB 7.2K 6Gbps NL SATA 3.5" G2SS HDD8
81Y9814A22VIBM 3TB 7.2K 6Gbps NL SATA 3.5" G2SS HDD8

Internal backup units

The server supports the internal tape drive options listed in the following table.

Table 10. Internal tape drives

Part
number
Feature
code
DescriptionMaximum
supported
00D2786A2VEIBM RDX Internal USB 3.0 Dock with 320GB Cartridge1
00D2787A2VFIBM RDX Internal USB 3.0 Dock with 500GB Cartridge1
00D2788A2VGIBM RDX Internal USB 3.0 Dock with 1TB Cartridge1
46C5364 -IBM RDX Removable Hard Disk System - Internal USB 160 GB Bundle1
46C5387 -IBM RDX Removable Hard Disk System - Internal USB 320 GB Bundle1
46C5388 -IBM RDX Removable Hard Disk System - Internal USB 500 GB Bundle1
46C53995711IBM DDS Generation 5 USB Tape Drive1
39M56365395IBM DDS Generation 6 USB Tape Drive1
43W84785393IBM Half High LTO Gen 3 SAS Tape Drive2*
44E88955397IBM Half High LTO Gen 4 SAS Tape Drive2*
49Y98985345IBM Half High LTO Gen 5 Internal SAS Tape Drive2*
* Note: With standard models, installation of a second tape drive requires removal of DVD-ROM.

USB tape drives are attached to the internal USB connector. SAS tape drives require SAS HBA (sold separately). See Table 13 for list of available SAS HBAs.

For more information, see the list of IBM Redbooks Product Guides in the Backup units category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=tape

Optical drives

The server supports the optical drive options listed in the following table.

Table 11. Optical drives

Part numberFeature
code
DescriptionMaximum quantity
supported
Standard models
where used
None*4154Half-High SATA DVD-ROM2A2x, B2x, C2x, C4x, D2x, F2x, G2x, H2x, J2x
81Y64044155Half-High SATA Multiburner2-
* This option is only available via CTO or is already installed in standard models.

The two half-high drives in the table can be installed in any open 5.25" drive bay (Figure 5).

Half-High SATA DVD-ROM supports the following media and speeds for reading:
  • CD-ROM 48X
  • CD-DA (DAE) 40X
  • CD-R 48X
  • CD-RW 40X
  • DVD-ROM (single layer) 16X
  • DVD-ROM (dual layer) 12X
  • DVD-R (4.7 GB) 16X
  • DVD-R DL 12X
  • DVD+R 16X
  • DVD+R DL 12X
  • DVD-RW (4.7 GB) 12X
  • DVD+RW 12X
  • DVD-RAM (4.7/9.4 GB) 6X

Half-High SATA multiburner supports the same media and speeds for reading as HH DVD-ROM. In addition, this drive supports the following media and speeds for writing:

  • CD-R 24X
  • CD-RW 4X
  • High Speed CD-RW 10X
  • Ultra Speed CD-RW 16X
  • DVD-R 8X
  • DVD-R DL 8X
  • DVD+R 8X
  • DVD+R DL 8X
  • DVD-RW 6X
  • DVD+RW 8X
  • DVD-RAM 3X

I/O expansion options

The server supports up to eight PCIe slots: six slots (1 to 6) when one CPU is installed or eight slots when two CPUs are installed. These are the slot form factors:

  • Slot 1: PCIe x8 (x4 wired); full-height, half-length (supports optional PCI-X interposer card)
  • Slot 2: PCIe x8; full-height, half-length
  • Slot 3: PCIe x8; full-height, full-length
  • Slot 4: PCIe x8 (x4 wired); full-height, full-length
  • Slot 5: PCIe x16; full-height, full-length
  • Slot 6: PCIe x8 (x4 wired); full-height, full-length
  • Slot 7: PCIe x16; full-height, full-length (requires second processor)
  • Slot 8: PCIe x16; full-height, full-length (requires second processor)

All PCIe slots are PCI Express 3.0 slots except Slot 1, which is a PCI Express 2.0 slot. Slot 1 can be converted to a PCI-X slot with the PCI-X Conversion Kit, which is described in the following table.

Table 12. PCI riser card options
Part numberFeature
code
DescriptionMaximum
supported
81Y7012A1G3PCI-X Interposer Conversion Kit1

Network adapters

x3500 M4 has four integrated Gigabit Ethernet ports. Integrated NICs have the following features:

  • Intel I350AM4 chip
  • Four GbE ports
  • TCP Offload Engine (TOE) support
  • Wake on LAN support
  • 802.1Q VLAN tagging support
  • NIC Teaming (load balancing and failover)

The following table lists additional supported network adapters.

Table 13. Network adapters
Part numberFeature
code
DescriptionMaximum quantity
supported
(1 CPU / 2 CPUs)
10 Gb Ethernet
49Y7910A18YBroadcom NetXtreme II Dual Port 10GBase-T Adapter for IBM System x6 / 8
95Y3762A2U1Emulex Dual Port 10GbE SFP+ VFA III for IBM System x6 / 8
None#A2UNEmulex Dual Port 10GbE SFP+ Integrated VFA III for IBM System x1
49Y7960A2ECIntel X520-DA2 Dual Port 10GbE SFP+ Adapter for IBM System x6 / 8
49Y7970A2EDIntel X540-T2 Dual Port 10GBase-T Adapter for IBM System x6 / 8
Converged Network Adapters (CNA)
42C18005751QLogic 10 Gb Dual Port CNA for IBM System x6 / 8**
42C18201637Brocade 10 Gb Dual-port CNA for IBM System x6 / 8**
Gigabit Ethernet
39Y60661485NetXtreme II 1000 Express Ethernet Adapter6 / 8
42C17802995NetXtreme II 1000 Express Dual Port Ethernet Adapter6 / 8
49Y42205766NetXtreme II 1000 Express Quad Port Ethernet Adapter6 / 8
42C17502975PRO/1000 PF Server Adapter by Intel6 / 8
49Y42305767Intel Ethernet Dual Port Server Adapter I340-T2 for IBM System x6 / 8
49Y42405768Intel Ethernet Quad Port Server Adapter I340-T4 for IBM System x6 / 8
90Y9352A2V3Broadcom NetXtreme I Quad Port GbE Adapter for IBM System x6 / 8
90Y9370A2V4Broadcom NetXtreme I Dual Port GbE Adapter for IBM System x6 / 8
# Emulex Dual Port 10GbE SFP+ Integrated VFA III is only available through CTO or Special Bid (SBB 95Y3768)
** Converged Network Adapters require SFP+ optical transceivers or DAC cables that must be purchased separately.

For more information, see the list of IBM Redbooks Product Guides in the Networking adapters category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=networkadapters

Storage host bus adapters

The following table lists storage HBAs supported by the x3500 M4 server.

Table 14. Storage adapters

Part numberFeature
code
DescriptionMaximum quantity
supported
(1 CPU / 2 CPUs)
Fibre Channel
81Y1668A2XUBrocade 16Gb FC Single-port HBA for IBM System x6 / 8
81Y1675A2XVBrocade 16Gb FC Dual-port HBA for IBM System x6 / 8
81Y1655A2W5Emulex 16Gb FC Single-port HBA for IBM System x6 / 8
81Y1662A2W6Emulex 16Gb FC Dual-port HBA for IBM System x6 / 8
46M60493589Brocade 8 Gb FC Single-port HBA for IBM System x6 / 8
46M60503591Brocade 8 Gb FC Dual-port HBA for IBM System x6 / 8
42D04853580Emulex 8 Gb FC Single-port HBA for IBM System x6 / 8
42D04943581Emulex 8 Gb FC Dual-port HBA for IBM System x6 / 8
42D05013578QLogic 8 Gb FC Single-port HBA for IBM System x6 / 8
59Y19873885Brocade 4 Gb FC Single-port HBA for IBM System x6 / 8
59Y19933886Brocade 4 Gb FC Dual-port HBA for IBM System x6 / 8
42C20691698Emulex 4 Gbps FC Single-Port PCI-e HBA for IBM System x6 / 8
42C20711699Emulex 4 Gbps FC Dual-Port PCI-e HBA for IBM System x6 / 8
39R65253567QLogic 4 Gb FC Single-Port PCIe HBA for IBM System x6 / 8
39R65273568QLogic 4 Gb FC Dual-Port PCIe HBA for IBM System x6 / 8
SAS
46M09075982IBM 6 Gb SAS HBA Controller6 / 8

For more information, see the list of IBM Redbooks Product Guides in the Host bus adapters category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=hba

PCIe SSD adapters

Currently, the server does not support High IOPS SSD adapters.

GPU adapters

The x3500 M4 server supports graphics processing units (GPUs) listed in the following table. Up to two GPUs are supported depending on the number of processors installed in a server (one GPU in slot 5 with one processor installed, or two GPUs in slot 5 and slot 7 with two processors installed).

Table 15. GPU adapters

Part numberFeature codeDescriptionMax. qty
supported
(1 CPU / 2 CPUs)
00D4484*A26QNVIDIA Quadro 60001 / 2
94Y59574798NVIDIA Quadro 40001 / 2
00W2299A1QUNVIDIA Quadro 20001 / 2
81Y6399A13KNVIDIA Quadro 6001 / 2
* If NVIDIA Quadro 6000 is installed in a PCIe slot, the next PCIe slot can not be used (if adapter is installed in slot 5, slot 6 can not be used; if adapter is installed in slot 7, slot 8 can not be used).

The use of a GPU adapter requires installation of one or two 900 W power supplies. 550 W or 750 W power supplies are not supported.

Power supplies and redundant cooling

The server supports up to two redundant power supplies. Standard models come with one or two power supplies (model dependent). The server also comes standard with either two (for models with one processor installed) or three (for models with two processors installed) simple swap cooling fans. Optional upgrade is available to provide N+N cooling redundancy. The following table lists the power supplies and redundant cooling upgrade option.

Table 16. Power supplies

Part numberFeature codeDescriptionMaximum
supported
Standard models
where used
94Y5975A22MIBM System x 550W High Efficiency Platinum AC Power Supply2-
94Y5974A1G8IBM System x 750W High Efficiency Platinum AC Power Supply2A2x, B2x, C2x, C4x, D2x, F2x
94Y5973A1G7IBM System x 900W High Efficiency Platinum AC Power Supply2G2x, H2x, J2x
81Y7007A1G2Redundant Cooling Upgrade Kit1-

Certain rules apply to the selection of power supply, these rules are listed in Table 17. Table 17 uses the following conventions:
  • A grey cell means that the server can be filled with drives, GPUs, processors and DIMMs up to the maximum number according to server specifications.
  • A yellow cell means that the maximum number of drives, GPUs, processors or DIMMs that the server can hold is fewer than the total number listed in server specifications.

Table 17. Configuration rules based on power supply used (PSU = power supply unit, NS = no support)
Power
supply
PSU
qty
PSU red.*Max. drive qtyIntermixing
2.5" + 3.5"
Max. GPU qtyCPU supportMax. DIMM qty supported
2.5"3.5"UDIMMRDIMMLRDIMM
550 W 1No88No supportNSMax. 95 W1616 SR or DR
(NS for QR)
NS
2Yes88No supportNSMax. 95 W1616 SR or DR
(NS for QR)
NS
750 W1No1688 + 8 drivesNSAll (135 W)162416
2Yes1688 + 8 drivesNSAll (135 W)162416
900 W1No3288 + 8 drivesNSAll (135 W)162416
1No88No support1 GPUAll (135 W)162416
1No1688 + 8 drivesNSAll (135 W)162424
2Yes3288 + 8 drivesNSAll (135 W)162416
2Yes88No support1 GPUAll (135 W)162416
2Yes1688 + 8 drivesNSAll (135 W)162424
2No3288 + 8 drives2 GPUsAll (135 W)162424
* PSU redundancy

An AC power supply ships standard without a line cord, it must be purchased separately. The redundant cooling kit contains three simple swap fans.

Integrated virtualization

The server supports VMware ESXi installed on a USB memory key. The key is installed in a USB socket inside the server. The following table lists the virtualization options.

Table 18. Virtualization options

Part numberFeature
code
DescriptionMaximum
supported
41Y8300 A2VCIBM USB Memory Key for VMware vSphere 5.01
41Y8307A383IBM USB Memory Key for VMware ESXi 5.0 Update11

Remote management

The server contains IBM Integrated Management Module II (IMM2), which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. Optionally, the IMM2 also provides a virtual presence capability for remote server management capabilities.

The IMM2 provides remote server management through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3
  • Common Information Model (CIM)
  • Web browser

The optional IMM Advanced Upgrade (software feature) is required to enable the remote presence and blue-screen capture features. The remote presence feature provides the following functions:
  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel color depths, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
  • Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive

The blue-screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating-system hang condition. A system administrator can use the blue-screen capture to assist in determining the cause of the hang condition. The following table lists the remote management option.

Table 19. Remote management option
Part numberFeature
code
DescriptionMaximum
supported
90Y3901A1MLIBM Integrated Management Module Advanced Upgrade1

Supported operating systems

The server supports the following operating systems:

  • Microsoft Windows Server 2008 R2
  • Microsoft Windows Server 2008, Datacenter x64 Edition
  • Microsoft Windows Server 2008, Datacenter x86 Edition
  • Microsoft Windows Server 2008, Enterprise x64 Edition
  • Microsoft Windows Server 2008, Enterprise x86 Edition
  • Microsoft Windows Server 2008, Standard x64 Edition
  • Microsoft Windows Server 2008, Standard x86 Edition
  • Microsoft Windows Server 2008, Web x64 Edition
  • Microsoft Windows Server 2008, Web x86 Edition
  • Microsoft Windows Small Business Server 2008 Premium Edition
  • Microsoft Windows Small Business Server 2008 Standard Edition
  • Red Hat Enterprise Linux 5 Server Edition
  • Red Hat Enterprise Linux 5 Server with Xen x64 Edition
  • Red Hat Enterprise Linux 5 Server x64 Edition
  • Red Hat Enterprise Linux 6 Server Edition
  • Red Hat Enterprise Linux 6 Server x64 Edition
  • SUSE LINUX Enterprise Server 10 for AMD64/EM64T
  • SUSE LINUX Enterprise Server 10 for x86
  • SUSE LINUX Enterprise Server 11 for AMD64/EM64T
  • SUSE LINUX Enterprise Server 11 for x86
  • SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
  • VMware ESX 4.1
  • VMware ESXi 4.1
  • VMware vSphere 5

See the IBM ServerProven® website for the latest information about the specific versions and service levels supported and any other prerequisites:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

Physical and electrical specifications

Dimensions and weight (approximate):

Tower:

  • Width: 218 mm (8.6 in)
  • Depth: 750 mm (29.5 in)
  • Height: 440 mm (17.3 in)
  • Weight:
    • Minimum configuration: 25.0 kg (55.1 lb)
    • Maximum configuration: 39.8 kg (87.7 lb)

Rack (using the Tower-to-Rack Conversion Kit, 81Y7006):
  • Width: 424 mm (16.7 in)
  • Depth: 702 mm (27.6 in)
  • Height: 218 mm (8.5 in)
  • Weight:
    • 24.5 kg (53.9 lb) (minimum configuration)
    • 39.3 kg (86.6 lb) (maximum configuration)

Supported environment:
  • Air temperature
    • Server on: 10 - 35 °C (50 to 95 °F); altitude: 0 - 915 m (3,000 ft)
    • Server on: 10 - 32 °C (50 - 90 °F); altitude: 915 m (3,000 ft) - 2,134 m (7,000 ft)
    • Server on: 10 - 28 °C (50 - 83 °F); altitude: 2,134 m (7,000 ft) - 3,050 m (10,000 ft)
    • Server off (with standby power): 5 - 45 °C (41.0 - 113 °F)
    • Shipping: -40 - 60 °C (-40 - 140 °F)
  • Humidity
    • Server on: 20 - 80% , Max. Dew Point 21 °C, Max. rate of change 5 °C/hr
    • Server off: 8 - 80%, Max. Dew Point 27 °C
  • Electrical
    • Models with 900 W power supplies:
      • 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 11 A
      • 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 5.5 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.6 kVA
        • Maximum configuration: 1.1 kVA
    • Models with 750 W power supplies:
      • 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 8.9 A
      • 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.5 A
      • Input kilovolt-amperes (kVA) (approximately):
        • Minimum configuration: 0.6 kVA
        • Maximum configuration: 0.9 kVA
  • BTU output
      • Minimum configuration: 2013 Btu/hr (590 watts)
      • Maximum configuration: 3610 Btu/hr (1056 watts)

Warranty options

The IBM System x3500 M4 has a 3-year onsite warranty with 9x5/next business day terms. IBM offers the warranty service upgrades through IBM ServicePacs, discussed in this section. The IBM ServicePac is a series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

IBM ServicePac offerings are country-specific. That is, each country might have its own service types, service levels, response times, and terms and conditions. Not all covered types of ServicePacs might be available in a particular country. For more information about IBM ServicePac offerings available in your country visit the IBM ServicePac Product Selector at:

https://www-304.ibm.com/sales/gss/download/spst/servicepac

The following table explains warranty service definitions in more detail.

Table 20. Warranty service definitions

TermDescription
IBM onsite repair (IOR)A service technician will come to the server's location for equipment repair.
24x7x2 hourA service technician is scheduled to arrive at your customer’s location within two hours after remote problem determination is completed. We provide service around the clock, every day, including IBM holidays.
24x7x4 hourA service technician is scheduled to arrive at your customer’s location within four hours after remote problem determination is completed. We provide service around the clock, every day, including IBM holidays.
9x5x4 hourA service technician is scheduled to arrive at your customer’s location within four business hours after remote problem determination is completed. We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding IBM holidays. If after 1:00 p.m. it is determined that onsite service is required, the customer can expect the service technician to arrive the morning of the following business day. For noncritical service requests, a service technician will arrive by the end of the following business day.
9x5 next business dayA service technician is scheduled to arrive at your customer’s location on the business day after we receive your call, following remote problem determination. We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding IBM holidays.

In general, the types of IBM ServicePacs are as follows:
  • Warranty and maintenance service upgrades
    • One, 2, 3, 4, or 5 years of 9x5 or 24x7 service coverage
    • Onsite repair from next business day to 4 or 2 hours
    • One or 2 years of warranty extension
  • Remote technical support services
    • One or three years with 24x7 coverage (severity 1) or 9x5/next business day for all severities
    • Installation and startup support for System x servers
    • Remote technical support for System x servers
    • Software support - Support Line
      • Microsoft or Linux software
      • VMware
      • IBM Director

Regulatory compliance

The server conforms to the following standards:

  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 4, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1-07
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • Australia/New Zealand AS/NZS CISPR 22:2006, Class A
  • IEC-60950-1 (CB Certificate and CB Test Report)
  • Taiwan BSMI CNS13438, Class A; CNS14336-1
  • China CCC (GB4943-2001), GB9254-2008 class A, GB17625.1-2003
  • Korea KN22, Class A; KN24
  • CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
  • CISPR 22, Class A
  • TUV-GS EN60950-1 /IEC60950-1,EK1-ITB2000)
  • Russia/GOST ME01, IEC-60950-1, GOST R 51318.22-99, GOST R 51318.24-99, GOST R 51317.3.2-99, GOST R 51317.3.3-99
  • IEC 60950-1 (CB Certificate and CB Test Report)

External disk storage expansion

The server supports attachment to external storage expansion enclosures, such as the EXP2500 series, by using the ServeRAID M5120 SAS/SATA Controller. The server can also be attached to supported external storage systems, such as the IBM System Storage® DS3500 series, using the supported HBAs listed in Table 14.

The following table provides the ordering part numbers for the ServeRAID M5120 SAS/SATA Controller.

Table 21. Ordering part numbers and feature codes

Part numberFeature codeDescriptionMaximum quantity
supported
81Y4478A1WXServeRAID M5120 SAS/SATA Controller3*
81Y4484A1J3ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade3*
81Y4487A1J4ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade3*
81Y4559A1WYServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade3*
81Y4508A22EServeRAID M5100 Series Battery Kit3*
81Y4546A1X3ServeRAID M5100 Series RAID 6 Upgrade1**
90Y4273A2MCServeRAID M5100 Series SSD Performance Accelerator1**
90Y4318A2MDServeRAID M5100 Series SSD Caching Enabler1**
* The maximum number of remotely mounted battery/supercap units must not exceed 3 for all controllers installed in a server. This may further limit the maximum number of M5120 controllers supported.
** One M5100 Series FoD software license is required per server.

The ServeRAID M5120 SAS/SATA Controller has the following specifications:
  • Eight external 6 Gbps SAS/SATA ports
  • Two external x4 mini-SAS connectors (SFF-8088)
  • Supports RAID levels 0, 1, and 10
  • Supports RAID levels 5 and 50 with optional M5100 Series RAID 5 upgrades
  • Supports RAID 6 and 60 with the optional M5100 Series RAID 6 Upgrade
  • Supports 512 MB battery-backed cache or 512 MB or 1 GB flash-backed cache (cache)
  • 6 Gbps throughput per port
  • PCIe 3.0 x8 host interface
  • Based on the LSI SAS2208 6 Gbps ROC controller
  • Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures

For more information, see the IBM Redbooks® Product Guide ServeRAID M5120 SAS/SATA Controller for IBM System x at:
http://www.redbooks.ibm.com/abstracts/tips0858.html?Open

The ServeRAID M5120 SAS/SATA Controller supports connectivity to the IBM System Storage external expansion enclosures listed in the following table. Up to nine expansion enclosures can be daisy-chained per one M5120 external port. For better performance, distribute expansion enclosures evenly across both M5120 ports.

Table 22. IBM System Storage external expansion enclosures
Part numberDescriptionMaximum quantity
supported per one M5120
174712XIBM System Storage EXP2512 Express18
174724XIBM System Storage EXP2524 Express9

The external SAS cables listed in the following table support connectivity between external expansion enclosures and the ServeRAID M5120 SAS/SATA Controller.

Table 23. External SAS cables for external storage expansion enclosures
Part numberDescriptionMaximum quantity
supported per one enclosure
39R6531IBM 3 m SAS Cable1
39R6529IBM 1 m SAS Cable1

The following table lists the drives supported by EXP2512 external expansion enclosures.

Table 24. Drive options for EXP2512 external expansion enclosures
Part numberDescriptionMaximum quantity supported
per one enclosure
3.5-inch NL SAS HS HDDs
49Y19031TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
49Y19022TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
90Y87203TB 7,200 rpm 6Gb SAS NL 3.5" HDD12
3.5-inch SAS HS HDDs
49Y1899300GB 15,000 rpm 6Gb SAS 3.5" HDD12
49Y1900450GB 15,000 rpm 6Gb SAS 3.5" HDD12
49Y1901600GB 15,000 rpm 6Gb SAS 3.5" HDD12

The following table lists the hard disk drives supported by EXP2524 external expansion enclosures.

Table 25. Drive options for EXP2524 external expansion enclosures
Part numberDescriptionMaximum quantity supported
per one enclosure
2.5-inch NL SAS HS HDDs
49Y1898500GB 7,200 rpm 6Gb SAS NL 2.5” HDD24
81Y99521TB 7,200 rpm 6Gb SAS NL 2.5” HDD24
2.5-inch SAS HS HDDs
49Y1896146GB 15,000 rpm 6Gb SAS 2.5” HDD24
49Y1895300GB 10,000 rpm 6Gb SAS 2.5” HDD24
81Y9944300GB 15,000 rpm 6Gb SAS 2.5” HDD24
81Y9596600GB 10,000 rpm 6Gb SAS 2.5” HDD24
81Y9948900GB 10,000 rpm 6Gb SAS 2.5” HDD24
2.5-inch SAS HS SSDs
81Y9956200GB 2.5" SAS SSD24
81Y9960400GB 2.5" SAS SSD24

External disk storage systems

The following table lists the external storage systems that are supported by the server and can be ordered through the System x sales channel. The server might support other IBM disk systems that are not listed in this table. Refer to IBM System Storage® Interoperation Center for further information.

Table 26. External disk storage systems

Part numberDescription
1746A2D IBM System Storage DS3512 Express Dual Controller Storage System
1746A2S IBM System Storage DS3512 Express Single Controller Storage System
1746A4D IBM System Storage DS3524 Express Dual Controller Storage System
1746A4S IBM System Storage DS3524 Express Single Controller Storage System
181494HIBM System Storage DS3950 Model 94
181498HIBM System Storage DS3950 Model 98
181492HIBM System Storage EXP395 Expansion Unit
1746A2EIBM System Storage EXP3512 Express Storage™ Expansion Unit
1746A4EIBM System Storage EXP3524 Express Storage Expansion Unit

For more information, see the list of IBM Redbooks Product Guides in the System Storage category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=externalstorage

External backup units

The server supports the external backup attachment options listed in Table 27.

Table 27. External backup options

Part numberDescription
36251TYIBM RDX USB 3.0 Dock with 1TB Cartridge (external)
362532YIBM RDX USB 3.0 Dock with 320GB Cartridge (external)
362550YIBM RDX USB 3.0 Dock with 500GB Cartridge (external)
362516XIBM RDX Removable Hard Disk Storage System - External USB 160 GB Bundle
362532XIBM RDX Removable Hard Disk Storage System - External USB 320 GB Bundle
362550XIBM RDX Removable Hard Disk Storage System - External USB 500 GB Bundle
3628L3XIBM Half High LTO Gen 3 External SAS Tape Drive (with US line cord)
3628L4XIBM Half High LTO Gen 4 External SAS Tape Drive (with US line cord)
3628L5X IBM Half High LTO Gen 5 External SAS Tape Drive (with US line cord)
3628N3XIBM Half High LTO Gen 3 External SAS Tape Drive (without line cord)
3628N4XIBM Half High LTO Gen 4 External SAS Tape Drive (without line cord)
3628N5XIBM Half High LTO Gen 5 External SAS Tape Drive (without line cord)
3580S3VSystem Storage TS2230 Tape Drive Express Model H3V
3580S4VSystem Storage TS2240 Tape Drive Express Model H4V
3580S5ESystem Storage TS2250 Tape Drive Express Model H5S
3580S5XSystem Storage TS2350 Tape Drive Express Model S53
3572S4RTS2900 Tape Library with LTO4 HH SAS drive & rack mount kit
3572S5RTS2900 Tape Library with LTO5 HH SAS drive & rack mount kit
35732ULTS3100 Tape Library Model L2U Driveless
35734ULTS3200 Tape Library Model L4U Driveless
46X2682†LTO Ultrium 5 Fibre Channel Drive
46X2683†LTO Ultrium 5 SAS Drive Sled
46X2684†LTO Ultrium 5 Half High Fibre Drive Sled
46X2685†LTO Ultrium 5 Half High SAS Drive Sled
46X6912†LTO Ultrium 4 Half High Fibre Channel Drive Sled
46X7117†LTO Ultrium 4 Half High SAS DriveV2 Sled
46X7122†LTO Ultrium 3 Half High SAS DriveV2 Sled
† These part numbers are the tape drives options for 35732UL and 35734UL.

Note: The external tape drives listed can be ordered through the System x sales channel. The server might support other IBM tape drives that are not listed in this table. Refer to IBM System Storage Interoperation Center for further information.

External USB tape drives are connected to the external USB ports on the server. External SAS or Fibre Channel tape drives require respective HBA (sold separately, see Table 14).

See the IBM ServerProven website for the latest information about the specific versions and service levels supported and any other prerequisites:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

For more information, see the list of IBM Redbooks Product Guides in the Backup units category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=tape

Top-of-rack Ethernet switches

The server supports the top-of-rack Ethernet switches from IBM System Networking listed in the following table.

Table 28. IBM System Networking: Top-of-rack switches

Part numberDescription
IBM System Networking - 1 Gb top-of-rack switches
0446013IBM System Networking RackSwitch G8000R
7309CFCIBM System Networking RackSwitch G8000F
7309CD8IBM System Networking RackSwitch G8000DC
7309G52IBM System Networking RackSwitch G8052R
730952FIBM System Networking RackSwitch G8052F
427348EIBM Ethernet Switch J48E
6630010Juniper Networks EX2200 24 Port
6630011Juniper Networks EX2200 24 Port with PoE
6630012Juniper Networks EX2200 48 Port
6630013Juniper Networks EX2200 48 Port with PoE
IBM System Networking - 10 Gb top-of-rack switches
0446017IBM System Networking RackSwitch G8124R
7309BF9IBM System Networking RackSwitch G8124F
7309BD5IBM System Networking RackSwitch G8124DC
7309BR6IBM System Networking RackSwitch G8124ER
7309BF7IBM System Networking RackSwitch G8124EF
7309G64IBM System Networking RackSwitch G8264R
730964FIBM System Networking RackSwitch G8264F
7309-CR9IBM System Networking RackSwitch G8264TR
7309-CF9IBM System Networking RackSwitch G8264TF
0719-410Juniper Networks EX4500 - Front to Back Airflow
0719-420Juniper Networks EX4500 - Back to Front Airflow
IBM System Networking - 40 Gb top-of-rack switches
8036ARXIBM System Networking RackSwitch G8316R
8036AFXIBM System Networking RackSwitch G8316F

For more information, see the list of IBM Redbooks Product Guides in the Top-of-rack switches category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=tor

Uninterruptible power supply units

The server supports attachments to the uninterruptible power supply (UPS) units listed in the following table.

Table 29. Uninterruptible power supply units

Part numberDescription
Tower UPS
53961AXIBM 1000VA LCD Tower UPS (120V)
53961JXIBM 1000VA LCD Tower UPS (100V)
53961KXIBM 1000VA LCD Tower UPS (230V)
53962AXIBM 1500VA LCD Tower UPS (120V)
53962JXIBM 1500VA LCD Tower UPS (100V)
53962KXIBM 1500VA LCD Tower UPS (230V)
Rack-mounted UPS
21304RX IBM UPS 10000XHV
53951AXIBM 1500VA LCD 2U Rack UPS (100V/120V)
53951KXIBM 1500VA LCD 2U Rack UPS (230V)
53952AXIBM 2200VA LCD 2U Rack UPS (100V/120V)
53952KXIBM 2200VA LCD 2U Rack UPS (230V)
53953AX IBM 3000VA LCD 3U Rack UPS (100V/120V)
53953JX IBM 3000VA LCD 3U Rack UPS (200V/208V)
53956AX IBM 6000VA LCD 4U Rack UPS (200V/208V)
53956KX IBM 6000VA LCD 4U Rack UPS (230V)
53959KXIBM 11000VA LCD 5U Rack UPS (200V/208V/230V)

For more information, see the list of IBM Redbooks Product Guides in the Power infrastructure category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=power

Power distribution units

The server supports attachments to the power distribution units (PDUs) listed in the following table.

Table 30. Power distribution units

Part numberDescription
Switched and Monitored PDUs
46M4002 IBM 1U 9 C19/3 C13 Active Energy Manager DPI® PDU
46M4003 IBM 1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU
46M4004 IBM 1U 12 C13 Active Energy Manager DPI PDU
46M4005 IBM 1U 12 C13 Active Energy Manager 60A 3 Phase PDU
46M4167IBM 1U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU
46M4116IBM 0U 24 C13 Switched and Monitored 30A PDU
46M4119IBM 0U 24 C13 Switched and Monitored 32A PDU
46M4134IBM 0U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU
46M4137IBM 0U 12 C19/12 C13 Switched and Monitored 32A 3 Phase PDU
Enterprise PDUs
71762MX IBM Ultra Density Enterprise PDU C19 PDU+ (WW)
71762NX IBM Ultra Density Enterprise PDU C19 PDU (WW)
71763MU IBM Ultra Density Enterprise PDU C19 3 Phase 60A PDU+ (NA)
71763NU IBM Ultra Density Enterprise PDU C19 3 Phase 60A PDU (NA)
39M2816IBM DPI C13 Enterprise PDU without linecord
39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed line cord
39Y8941 DPI Single Phase C13 Enterprise PDU without line cord
39Y8948 DPI Single Phase C19 Enterprise PDU without line cord
Front-end PDUs
39Y8934DPI 32 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector
39Y8935DPI 63amp/250 V Front-end PDU with IEC 309 2P+Gnd connector
39Y893830 amp/125 V Front-end PDU with NEMA L5-30P connector
39Y893930 amp/250 V Front-end PDU with NEMA L6-30P connector
39Y894060 amp/250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector
Universal PDUs
39Y8951DPI Universal Rack PDU with US LV and HV line cords
39Y8952DPI Universal Rack PDU with CEE7-VII Europe LC
39Y8953DPI Universal Rack PDU with Denmark LC
39Y8954DPI Universal Rack PDU with Israel LC
39Y8955 DPI Universal Rack PDU with Italy LC
39Y8956DPI Universal Rack PDU with South Africa LC
39Y8957DPI Universal Rack PDU with UK LC
39Y8958DPI Universal Rack PDU with AS/NZ LC
39Y8959DPI Universal Rack PDU with China LC
39Y8962DPI Universal Rack PDU (Argentina)
39Y8960DPI Universal Rack PDU (Brazil)
39Y8961DPI Universal Rack PDU (India)
0U Basic PDUs
46M4122IBM 0U 24 C13 16A 3 Phase PDU
46M4125 IBM 0U 24 C13 30A 3 Phase PDU
46M4128 IBM 0U 24 C13 30A PDU
46M4131IBM 0U 24 C13 32A PDU
46M4140 IBM 0U 12 C19/12 C13 60A 3 Phase PDU
46M4143IBM 0U 12 C19/12 C13 32A 3 Phase PDU

For more information, see the list of IBM Redbooks Product Guides in the Power infrastructure category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=power

Rack cabinets

The x3500 M4 server can be installed in the rack with the Tower to Rack Conversion Kit (81Y7006). The server supports the rack cabinets listed in the following table.

Table 31. Rack cabinets and Tower to Rack Conversion Kits

Part numberDescription
Tower to rack conversion kits
81Y7006Tower to Rack Conversion Kit
Rack cabinets
201886XIBM 11U Office Enablement Kit
93072PXIBM 25U Static S2 Standard Rack
93072RXIBM 25U Standard Rack
93074RXIBM 42U Standard Rack
93074XXIBM 42U Standard Rack Extension
93084EXIBM 42U Enterprise Expansion Rack
93084PXIBM 42U Enterprise Rack
93604EXIBM 42U 1200 mm Deep Dynamic Expansion Rack
93604PXIBM 42U 1200 mm Deep Dynamic Rack
93614EXIBM 42U 1200 mm Deep Static Expansion Rack
93614PXIBM 42U 1200 mm Deep Static Rack
93624EXIBM 47U 1200 mm Deep Static Expansion Rack
93624PXIBM 47U 1200 mm Deep Static Rack
99564RXIBM S2 42U Dynamic Standard Rack
99564XXIBM S2 42U Dynamic Standard Expansion Rack

For more information, see the list of IBM Redbooks Product Guides in the Rack cabinets and options category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=rack

Figure 6 shows the server installed in the Tower to Rack Conversion Kit.

The IBM System x3500 M4 with the Tower to Rack Conversion Kit
Figure 6. The IBM System x3500 M4 with the Tower to Rack Conversion Kit

Rack options

The server supports the rack console switches and monitor kits listed in the following table.

Table 32. Rack options

Part numberDescription
Monitor kits and keyboard trays
172317X1U 17in Flat Panel Console Kit
172319X1U 19in Flat Panel Console Kit
Console switches
1754D2XIBM Global 4x2x32 Console Manager (GCM32)
1754D1XIBM Global 2x2x16 Console Manager (GCM16)
1754A2XIBM Local 2x16 Console Manager (LCM16)
1754A1XIBM Local 1x8 Console Manager (LCM8)
Console cables
43V6147IBM Single Cable USB Conversion Option (UCO)
39M2895IBM USB Conversion Option (4 Pack UCO)
39M2897IBM Long KVM Conversion Option (4 Pack Long KCO)
46M5383IBM Virtual Media Conversion Option Gen2 (VCO2)
46M5382IBM Serial Conversion Option (SCO)

For more information, see the list of IBM Redbooks Product Guides in the Rack cabinets and options category:
http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=rack

IBM Global Financing

IBM Global Financing can help you obtain the IT solution you need while preserving funding for other strategic investments and optimizing cash flow. Our Fair Market Value (FMV) lease helps ensure that you have the latest IBM technology and with our mid-lease upgrade capability, you can increase the capacity of the system with little to no change in monthly payments. At the end of the lease, take advantage of our flexible end-of-lease options to fit your changing business needs. IBM Global Financing has the breadth and depth of offerings, longevity, proven success and global reach to help you develop a robust financing and asset management strategy that provides you the opportunity to leverage new technologies and turn your ambitious vision into a tangible solution.

Here are some other reasons why working with us makes solid financial sense:

  • Expand your purchasing power—Affordable monthly payments allow you to change the technology acquisition discussion from “what can I afford right now” to “what solution is really right for my business.” IBM Global Financing allows you to expand your purchase power to get you the right solution.
  • Accelerate your project’s cash flow break-even point—Acquire your IBM technology today and begin to realize its benefits now. An FMV lease can help you get the solution you need now, with low monthly payments that better align upfront costs with the anticipated return on investment from the technology.
  • Easy to acquire with affordable rates—We offer one-stop shopping for a total IT solution, so you can acquire IBM hardware, software, services and the financing you need—from one IT provider.

Plus, we provide simple, easy-to-understand contracts and quick approvals. As the world’s largest IT financing provider, with an asset base of US$35.8 billion and over 125,000 customers, IBM Global Financing offers highly competitive rates that promote low total cost of ownership and low monthly payments.

IBM Global Financing operates in more than 50 countries. Go to http://ibm.com/financing for financing options in your country and to contact a local financing specialist.

IBM Global Financing offerings are provided through IBM Credit LLC in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients. Rates and availability subject to client’s credit rating, financing terms, offering type, equipment and product type and options, and may vary by country. Non-hardware items must be one-time, non-recurring charges and are financed by means of loans. Other restrictions may apply. Rates and offerings are subject to change, extension or withdrawal without notice and may not be available in all countries. Please contact your local IBM Global Financing representative for additional detail.

Related publications and links

For more information see these resources:


Special Notices

This material has not been submitted to any formal IBM test and is published AS IS. It has not been the subject of rigorous review. IBM assumes no responsibility for its accuracy or completeness. The use of this information or the implementation of any of these techniques is a client responsibility and depends upon the client's ability to evaluate and integrate them into the client's operational environment.

Profile

Publish Date
06 March 2012

Last Update
01 January 2013


Rating:
(based on 3 reviews)


Author(s)

IBM Form Number
TIPS0852